3-6
Chapter 3
Installation
Summary
2. For HP-IB tape devices, connect the tape device to the HP-IB card in slot 3.
(Address 0/12.0.3).
iii. For systems with SCSI system disks:
1. For SCSI tape devices, connect the tape device to the SCSI card in slot 13 of
the internal HP-PB I/O card cage. (Address 0/52.0.0).
2. For HP-IB tape devices, connect the tape device to the HP-IB card in slot 3.
(Address 0/12.0.3).
iii. For systems with Fast/Wide SCSI system disks:
1. For SCSI tape devices, connect the tape device to the SCSI card in slot 9 of the
internal HP-PB I/O card cage. (Address 0/36.0.0).
2. For HP-IB tape devices, connect the tape device to the HP-IB card in slot 3.
(Address 0/12.0.3).
11.Verify system operation.
a. Make sure console, peripherals, expansion cabinets, and external HP-PB card cages
(if any) are powered up and ready.
b. Power up the computer:
i. Turn on the circuit breaker switch at the rear of the SPU cabinet.
ii. Turn the "Standby-Ready" switch on the front panel to the "Ready" position.
c. Enter the PDC user interface.
d. Enter the PDC command to enable or disable the memory page deallocation table
(PDT).
e. Verify that indicators show normal status.
f. Check the SP error log with the DL command (SP)
g. Check the autostart flag with the AF command (SP).
h. Check the PMB card cage configuration with the HC command (SP).
12.Set boot parameters.
a. Enter the PDC boot menu.
b. Verify/change autoboot flag.
c. Verify/change default hardware paths. See PDC on-line help for appropriate values.
13.Operating system.
a. Load the operating system if necessary. Some configurations are preloaded at the
factory.
b. Boot the operating system.
c. If OS patches are included with the system, install them now.
Содержание 3000 99x Family
Страница 8: ...Contents 6 Figures ...
Страница 10: ...Contents 8 Tables ...
Страница 12: ...Preface 2 ...
Страница 18: ...Preface 8 ...
Страница 20: ...Preface 10 ...
Страница 21: ...Chapter 1 1 1 Introduction 1 Introduction ...
Страница 30: ...1 10 Chapter1 Introduction Orientation Figure 1 2 SPU Cabinet Internal Layout Front ...
Страница 31: ...Chapter 1 1 11 Introduction Orientation Figure 1 3 SPU Cabinet Internal Layout Rear ...
Страница 32: ...1 12 Chapter1 Introduction Orientation ...
Страница 33: ...Chapter 2 2 1 Unpacking and Inspection 2 Unpacking and Inspection ...
Страница 43: ...Chapter 2 2 11 Unpacking and Inspection Moving the Cabinet to the Site Figure 2 5 Accessing the Lifting Nuts ...
Страница 48: ...2 16 Chapter2 Unpacking and Inspection Repackaging the Cabinet for Shipment ...
Страница 64: ...3 16 Chapter3 Installation PMB Cards Figure 3 6 Processor Main Bus PMB Card Cage Card Locations ...
Страница 68: ...3 20 Chapter3 Installation PMB Cards Figure 3 7 Inserting Removing a PMB Card ...
Страница 126: ...3 78 Chapter3 Installation Operating the Computer ...
Страница 142: ...A 16 AppendixA MPE iX Configuration and SYSGEN Default Configuration for 99x with HP FL Boot Device ALINK99x ...
Страница 143: ...Appendix B B 1 Configuring the HP PB Card Cage B Configuring the HP PB Card Cage ...
Страница 151: ...Appendix C C 1 Configuring the Remote Support Modem C Configuring the Remote Support Modem ...
Страница 168: ...C 18 AppendixC Configuring the Remote Support Modem Console LAN Card Modem Line Behavior ...
Страница 169: ...Appendix D D 1 Power Resiliency D Power Resiliency ...
Страница 171: ...Appendix D D 3 Power Resiliency Power System Figure D 1 PFC Module Locations ...
Страница 172: ...D 4 AppendixD Power Resiliency Power System Figure D 2 Power Modules and PMB Cards in the Front Card Cage T600 ...
Страница 173: ...Appendix D D 5 Power Resiliency Power System Figure D 3 Power Modules and PMB Cards in the Rear Card Cage T600 ...