Appendix A
A-7
MPE/iX Configuration and SYSGEN
Configuring the Remote Console
3. Use the LD command to list the current parameters for LDEV 21:
io> LD 21
You will see:
LDEV:
21
DEVNAME:
OUTDEV:
0
MODE:
ID: HPC2204A
RSIZE:
128
DEVTYPE: DISC
PATH: 0/36.0
MPETYPE:
4
MPESUBTYPE:
3 CLASS: DISC
SPOOL
4. Use the MD command to modify the parameters for LDEV 21:
io> MD 21 id=HP28639-60001-CONSOLE-TERMINAL path=0/44.1
5. Use the LD command to verify the change:
io> LD 21
You will see:
LDEV:
21 DEVNAME:
OUTDEV: 21
MODE:
JAID
ID: HP28639-60001-CONSOLE-TERMINAL RSIZE:
40 DEVTYPE: TERM
PATH: 0/44.1
MPETYPE:16
MPESUBTYPE: 0
6. Use the LP command to verify that the PMGR and LMGR are correct:
io> LP 0/44.1
See xref emscboot> and Table A-4 for the correct values.
7. Use the HOLD command to save the changes you have made:
io> HOLD
8. Use the EXIT command to exit the I/O Configurator:
io> EXIT
9. Use the KEEP command to keep the files from the configuration group to the
CONFIG.SYS group:
sysgen> KEEP CONFIG
10.Exit the SYSGEN program:
sysgen> EXIT
After the configuration is changed complete these additional steps:
1. Use NMMGR to set the modem type:
a. Open Config.
b. DTS.
c. Go To User Port.
d. Set the modem type as appropriate.
e. Save Data.
2. Validate DTS/LINK in NMMGR.
3. Cross-validate the configuration in SYSGEN by entering SYSGEN. Make sure there are
no new conflicts.
4. Create a new CSLT in SYSGEN. This saves the changes permanently.
Содержание 3000 99x Family
Страница 8: ...Contents 6 Figures ...
Страница 10: ...Contents 8 Tables ...
Страница 12: ...Preface 2 ...
Страница 18: ...Preface 8 ...
Страница 20: ...Preface 10 ...
Страница 21: ...Chapter 1 1 1 Introduction 1 Introduction ...
Страница 30: ...1 10 Chapter1 Introduction Orientation Figure 1 2 SPU Cabinet Internal Layout Front ...
Страница 31: ...Chapter 1 1 11 Introduction Orientation Figure 1 3 SPU Cabinet Internal Layout Rear ...
Страница 32: ...1 12 Chapter1 Introduction Orientation ...
Страница 33: ...Chapter 2 2 1 Unpacking and Inspection 2 Unpacking and Inspection ...
Страница 43: ...Chapter 2 2 11 Unpacking and Inspection Moving the Cabinet to the Site Figure 2 5 Accessing the Lifting Nuts ...
Страница 48: ...2 16 Chapter2 Unpacking and Inspection Repackaging the Cabinet for Shipment ...
Страница 64: ...3 16 Chapter3 Installation PMB Cards Figure 3 6 Processor Main Bus PMB Card Cage Card Locations ...
Страница 68: ...3 20 Chapter3 Installation PMB Cards Figure 3 7 Inserting Removing a PMB Card ...
Страница 126: ...3 78 Chapter3 Installation Operating the Computer ...
Страница 142: ...A 16 AppendixA MPE iX Configuration and SYSGEN Default Configuration for 99x with HP FL Boot Device ALINK99x ...
Страница 143: ...Appendix B B 1 Configuring the HP PB Card Cage B Configuring the HP PB Card Cage ...
Страница 151: ...Appendix C C 1 Configuring the Remote Support Modem C Configuring the Remote Support Modem ...
Страница 168: ...C 18 AppendixC Configuring the Remote Support Modem Console LAN Card Modem Line Behavior ...
Страница 169: ...Appendix D D 1 Power Resiliency D Power Resiliency ...
Страница 171: ...Appendix D D 3 Power Resiliency Power System Figure D 1 PFC Module Locations ...
Страница 172: ...D 4 AppendixD Power Resiliency Power System Figure D 2 Power Modules and PMB Cards in the Front Card Cage T600 ...
Страница 173: ...Appendix D D 5 Power Resiliency Power System Figure D 3 Power Modules and PMB Cards in the Rear Card Cage T600 ...