As shown in the example configuration in
Figure 22
, flow control is enabled globally, which would
enable flow control on all the ports in the switch.
Figure 22 Flow Control Page
Table 19 Flow Control Fields
Description
Field
Enable flow control on the switch. Clear to disable the feature.
Enable Flow Control
Click
Apply
to save any changes for the current boot session; the changes take effect immediately.
Green Features
The switch software allows the user to enable or disable port, cable, and LED energy saving features
that consume less power than the normal high-performance mode.
To display the Green Features configuration page, click
Switching > Green Features
in the navigation
pane.
Figure 23 Green Features
Table 20 Get Connected Fields
Description
Field
Port Energy Saving Configuration
Enable power save mode when there is no link. This feature is disabled by
default.
Auto Port Power-Down
EEE (Energy Efficient Ethernet) is designed to save power by turning off network
ports that are not passing traffic. EEE works for ports in auto-negotiation mode,
Low-Traffic Idle (EEE)
where the port is negotiated to either 100 Mbps Full Duplex or 1 Gbps (1000
Mbps) Full Duplex. Valid values are Disable and Enable. This feature is disabled
by default.
34
Switching Pages