background image

24 of 33

Service Manual UK

Indesit

Company

English

F06

Door lock fails to 
close / open, door 
lock PTC triac open 
/ closed, mains 
frequency signal 
fault, mains power 
signal fault

- Check for water leaks that may affect connectors 

J004

 or 

J11

(three-phase) causing the relative contacts to short;
- Check Door lock terminal board (any problems due to 
aggression caused by manufacturing chemical residues that may 
cause short circuits);
- Check 

J004

 / door lock wiring;

- Check door lock;
- Renew PCB.

F07

Wash heating 
element relay open 
/ diverter relay 
sticking on drain 
pump side

- Check efficiency of contacts on connector 

J001 

(commutator) or 

J10 

(three-phase) on PCB;

- Check continuity of wash heating element on connectors

J001 (Commutator) 

or

J10

 (Three-phase), pins 3 and 4.

The

1700W 230V 

heating element impedance value is 30 Ohm

+/

-

10%. If value is different renew wash heating element;

- Renew PCB.

F08

Wash heating 
element relay earth 
leak- age / wash 
heating element 
relay contacts 
sticking

- Check efficiency of contacts on connector 

J001

 (commutator) or 

J10

 (three-phase) on PCB;

- Check leakage between the two ends and ground, impedance 
should be at least 2 MOhm;
- Renew heating element;
- Renew PCB.

F09

Setting File error 
detected by Main 
PCB or Display 
PCB

- Disconnect appliance for 2 minutes. Check that correct 
operation has been restored by starting the Autotest routine;
- Reprogram Main PCB;
- Renew main PCB;
- Renew display PCB.

F11

Pump not wired or 
pump driving triac 
short circuit

- Check efficiency of contacts on connector 

J004

 (commutator) or 

J11

 (three-phase) on PCB;

- Check continuity on connector 

J004

 (commutator) or 

J11

 (three- 

phase), pins 4 and 5 (in the case of classic door lock);
- Check continuity of pump, ensuring that impedance value is 170 
Ohm +/- 10%;
- Check wiring of connector 

J004

 (commutator) or 

J11

 (three 

phase) / pump;
- Renew pump;
- Renew PCB.

F12

Communication
error between Main 
PCB and Display 
PCB

- Check efficiency of contacts on connector 

J010

 (Commutator) or 

J16

 (Three-phase) on main PCB;

- Check efficiency of contacts on Display PCB;
- Check continuity of 

J010

 (Commutator) or 

J16

 (Three-phase)/ 

Display PCB wiring;
- Disconnect appliance, wait for 2 minutes and reconnect to power 
supply, then start autotest routine;
If problem persists proceed as follows:
- Renew main PCB;
- Renew display PCB.

Содержание WML540GUK.C

Страница 1: ...ASHING MACHINES Models Comm Covered Code EVO2 Controls WML540PUK C 56649 WML540PUK R 56803 Arcadia Controls WML540GUK C 69230 WML540GUK R 64622 WML540PUK CA 56649 WML540PUK RA 56803 Arcadia 2 75 Contr...

Страница 2: ...shers Food Centres etc checks must be made for leaks from seals gaskets and pipe work and rectification carried out where necessary 7 It can be dangerous to attempt DIY repairs maintenance on complex...

Страница 3: ...ndustrial Code Explanation 2 Index Introduction Dates 4 Specifications 5 Installation 6 8 Controls Options Programmes Controls 9 13 Power Module Layout Wiring Diagram EVO2 Arcadia Arcadia 2 75 14 20 E...

Страница 4: ...ry Radomsko 30 Poland WML540GUK C Industrial Code 80692300000 First Produced September 2009 Factory Comuanza 80 Italy WML540PUK CA Industrial Code 80566490185 First Produced December 2009 Factory Comu...

Страница 5: ...r Consumption 52 litres 60 C Cotton Wash Load From1 kg to 6 kg Cottons Wash Drum Outer Plastic Outer Drum 52 litre capacity Spin Speed 1400rpm Motor ACC CESET 52mm Split Field 4 fixing type Control PC...

Страница 6: ...he appliance 5 Keep all the removed parts as they will be required again if the washing machine needs to be moved to another location Levelling 1 Install the washing machine on a flat sturdy floor wit...

Страница 7: ...d cap Connect the other end of the water inlet hose to the washing machine screwing it onto the cold water inlet situated on the top right hand rear of the appliance see illustration Screw the inlet e...

Страница 8: ...g 1 Electrical Connections Before plugging the appliance into the mains socket make sure that the socket is earthed and in compliance with the applicable law the supply voltage is included within the...

Страница 9: ...ill light TO STOP OR CHANGE A PROGRAMME Press the ON OFF button for approximately 3 seconds Select PUMP OUT on the programme dial Switch on and re start When the machine has finished emptying Press th...

Страница 10: ...programme the LED will flash and a bleeping noise will be heard when pressing the button SUPERWASH An intensive wash using an increased volume of water during the initial phase of the cycle which inc...

Страница 11: ...11 of 33 Indesit Company Service Manual UK English PROGRAMMES WML540PUK C WML540PUK CA WML540PUK R WML540PUK RA...

Страница 12: ...12 of 33 Service Manual UK Indesit Company English PROGRAMMES WML540GUK C WML540GUK R...

Страница 13: ...DWLQJ WKH QHHG RI KHDWLQJ ZDWHU DQG LWoV DQ DGYDQWDJH ERWK WR RXU HQHU J ELOO DQG WKH HQYLURQPHQW 7KHVH LQQRYDWLYH FR SURJUDPPHV RWWRQ 6 QWKHWLFV DQG DVW DVK DUH DYDLODEOH IRU YDULRXV IDEULFV DQG GLII...

Страница 14: ...achieved by energising both the Pre Wash and Main Wash cold valves Out of Balance Protection The machine has an inbuilt feature to prevent spinning with an unbalanced load A calculation via the motor...

Страница 15: ...15 of 33 Indesit Company Service Manual UK English POWER MODULE CONNECTIONS SINGLE PHASE EVO2 Controls J11 J8 J10 J13 J14 J15 J9 J2 J1 J4 J3 AUTO TEST SOCKET external J5...

Страница 16: ...Lamp 3 4 2 4 3 2 WML540 evo2 pdf T M j9 5 4 1 2 3 4 6 7 1 2 3 5 6 7 5 4 3 2 1 5 4 3 2 1 2 1 2 1 1 OVERFLOW EVL EVP L P N L 12 1 14 11 16 Pressure Switch 1 5 R R R Test 1 3 1 2 1 2 1 2 2 3 4 1 2 3 4 1...

Страница 17: ...17 of 33 Indesit Company Service Manual UK English POWER MODULE CONNECTIONS Single Phase Arcadia Controls J005 AUTO TEST SOCKET external J009 J011 J004 J001 J012 J010 J006 J007...

Страница 18: ...4 5 6 7 7 6 5 3 2 1 7 6 4 3 2 1 4 5 6a 6a 6a 6a 6a M T COMMON OVERFLOW 1 3 2 16 11 14 1 12 4 5 3 4 10A 10A R R R T F UI 3 2 1 4 1 2 2 1 2 1 Lav 1 2 6 8 5 5 FULL 5 4 5 j001 j001 j006 j005 j009 j004 j0...

Страница 19: ...19 of 33 Indesit Company Service Manual UK English POWER MODULE CONNECTIONS ARCADIA 2 75 J001 J004 J009 J005 J010 J006 J007...

Страница 20: ...ACK 0 75 X 730 BLACK 0 75 X 730 RED 0 50 X 730 RED 0 50 X 730 BLACK 0 75 X 730 MAINS FILTER J01 FA2 FA1 R TF R R L N BLUE BROWN BLUE BROWN 4J1 2 1 GREEN YELLOW 1 0 X 1220 TG TR VALVES NTC THERMISTOR E...

Страница 21: ...triac short circuit Check motor and module connections F02 Motor jammed tacho detached Check motor and module connections F03 NTC short open circuit Check thermistor and module connections F04 Pressur...

Страница 22: ...or brush motor and three phase non brush motor models Refer to text for appropriate information FAULT CAUSE SERVICE ACTIONS F01 Main PCB Triac on board damaged or components Feedback fault Check for w...

Страница 23: ...s on connector J005 commutator or J12 three phase on PCB Check NTC ensuring that the impedance value at ambient temperature 20 C on wiring connector J005 commutator or J12 three phase pins 1 and 2 is...

Страница 24: ...or J10 three phase on PCB Check leakage between the two ends and ground impedance should be at least 2 MOhm Renew heating element Renew PCB F09 Setting File error detected by Main PCB or Display PCB D...

Страница 25: ...hort circuit Board relay sticking Check efficiency of contacts on connector J012 commutator or J13 three phase on PCB Check continuity of the dryer heating element on pins 1 and 2 of connector J012 co...

Страница 26: ...mart Card certain area s of UK market see photo IMPORTANT Is it EVO2 or ARCADIA When replacing a module with a new unprogrammed unit it is essential to use the correct Smartcard or if using Memwriter...

Страница 27: ...ad If appliance already has the most up to date file a warning box will appear indicating EEPROM ALREADY UPDATED NOTE When starting Memwriter programme the default selection is always GET FROM HARDWAR...

Страница 28: ...sengage the location fixings at the rear and lift off B Rear Access Panel 1 Remove 6 screws from the rear access panel 2 Slide panel down and lift clear C Dispenser Drawer 1 Open the dispenser drawer...

Страница 29: ...he inner drum 3 Remove 2 screws from the interlock 4 The interlock can now be eased out allowing access to the wiring connection block and emergency release strap 5 Care must be taken to ensure the co...

Страница 30: ...ss 4 When removing the hinges note the orientation To remove fold hinges inward slide towards each other to release other end See photo Reassemble in reverse order 5 To fully separate the halves slide...

Страница 31: ...onto one side 2 Remove the 10mm nut securing the damper to the cabinet 3 Push the damper on the rod until it comes out of the cabinet 4 Remove plastic expansion rivet which fixes the damper to the ta...

Страница 32: ...Remove the Table Top A Rear Access Panel B Console Panel D Dispenser S and Motor L 2 Remove the screws securing pump to front panel 3 Disconnect the wiring attached to the outer drum via cable clips a...

Страница 33: ...lacing a module with a new unprogrammed unit it is essential to use the correct Smartcard or if using Memwriter software on a PC or EMIT unit it is essential that the correct Platform such as EVO2 or...

Отзывы: