Operation and Setup
Task Settings and Notes
Regenerative Discharge Function
The HG PRO AC/DC smart charger has a regenerative discharge function of up to 700W,
which take the battery power of the output terminal back to input end's battery in the
balance way . There is no need to connect to or turn on power during operation,just directly
connect the battery ,which going to receive power, to the charger's input port, and wait for
the system self-test to complete, then connect the discharge battery to the charger's output
port, and set the task to "regeneration discharge" on the charger to discharge, and recycle;
for lithium battery, it is strongly recommended to connect to the balance port of the charger
for balanced discharge.
Input Port
Battery Activation And Repair
After the charging task starts, if it is detected that the cell voltage is lower than the pre-charging
voltage, the cell will be activated and repaired using one tenth of the task setting current. After
the voltage becomes higher than the pre-charging voltage, the voltage will be adjusted to the
set voltage for charging. Such design can protect the over-discharged battery , activate and
repair it.
-