Operation and Setup
Task Settings and Notes
External Discharge Function
The external discharge function uses the external high-power load resistor to quickly discharge
the battery accurately. When it is used, the battery to be discharged needs to be connected to the
input port, and the output is connected to the resister load. It is recommended that the resistance
of the load be between 1.5 and 2.5 ohms. Other resistance values can also be used normally, but
may not be able to operate at full power. When the external discharge is running, the load is very
hot. Please pay attention to safety and avoid accidents or personal injury.
Storage Function
When the storage function is selected, if the battery is lower than the preset storage voltage, the
charging task will be automatically performed; if the battery voltage is higher than the preset
storage voltage, the discharge task will be automatically performed. In order to save the task
time, the storage and discharge tasks do not accurately balance the cell voltage. There may be
some error between the cell voltage and the preset value at the end of the task, which is a normal
phenomenon.
Balance Function
The balance function is used to balance the voltage of cells and make them equal. The balance
time is related to the cell voltage difference and the target voltage. When the menu is switched
to the balance mode, the charger automatically analyzes and sets the initial balance voltage
value, and the user can freely adjust it. The charger's charging ability is much larger than the
discharge capacity; in the balance operation , selecting voltage equal or larger than the current
battery voltage usually lets you attain faster effect in balancing.
-
HGT1.
I
H6 PRO AC/DC Smart Charger