Polaris Beer Superchiller™
230V / 50Hz
lancerbeverage.com
Page 8 of 23
Hoshizaki Lancer reserve the right to change specifications without notice.
Part No: 68000200
Images are for illustration purposes only as product may vary.
013a – 25 November 2013
Water
- If the unit is to be used as an ice bank, simply fill with clean water until it flows out the
overflow tube.
6.8 Electrical
Connection
This unit is connected to the supply via a flexible cord fitted with a 3 pin plug.
Check the name plate on the machine for electrical supply requirements. Use only the power
supply specified on the name plate.
Warning
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
Warning
To avoid possible fatal electric shock or serious injury the
Chiller must be electrically grounded.
Electrical Connection Must Be Made In Accordance With The
Appropriate Local Codes And Regulations.
Use of an RCD is recommended.
6.9
Commissioning
Connect chiller power supply lead to an appropriate 3 pin socket outlet and switch on.
Compressor, condenser fans and pump/agi motor should all operate.
On initial start up, remove the pump plug to allow the tank temperature to reduce without the
unit cutting out on overload. If the unit cuts out during pull down, turn off at mains socket to
reset then continue to pull down as before.
Once the unit is cycling normally, the pump plug should be replaced, ensure the pump is
running.
Allow lines to fill. Ensure liquid level does not drop below pump intake during initial filling of the
python.
As required top up the unit.
Check all connections for leaks.
Fully insulate all chilled lines and ensure air tight at all connections.
Before running unit, sanitise product lines using beer line cleaner.
Glycol Units
:
Check water / glycol mixture with refractometer (refer to chart on page 12 for details).
Check the set point of the controller (reset per 6.11)
Monitor the indicated temperature on the thermostat and ensure temperature reduces to
the set point.
Don’t leave water in coils as the water will freeze.
6.10
Purge System
Progressively activate each fount connected to the Chiller systems to achieve an uninterrupted
flow of product.