PROBLEM
CHECK
POSSIBLE CAUSE
REMEDY
1. Bad contacts.
1. Check for continuity and
replace.
2. Voltage too low.
2. Check for recommended
voltage.
c) Overload
Protector
3. Refrigerant overcharged
or undercharged.
3. Recharge.
d) Starter
1. Defective.
1. Replace.
e) Start Capacitor
or Run
Capacitor
1. Defective.
1. Replace.
1. Bad contacts.
1. Check for continuity and
replace.
f) Magnetic
Contactor
2. Coil winding opened.
2. Replace.
1. Wiring to Compressor.
1. Check for loose
connection or open, and
replace.
g) Compressor
2. Defective.
2. Replace.
[2] (Continued)
h) Air Filter,
Condenser
1. Clogged.
1. Clean.
[3] Compressor
runs, but other
components
will not start.
a) Control Circuit
1. Loose connection or
broken wire.
1. Repair or replace.
a) Wiring
1. Loose connection or
broken wire.
1. Repair or replace.
b) Actuator Toggle
Switch
1. Defective.
1. Replace.
[4] Fan Motor will
not run.
c) Thermistor,
Controller Board
1. See “II. 2. CONTROLLER BOARD”.
a) Water Solenoid
Valve
1. Diaphragm does not
close.
1. Check for water leaks
with icemaker OFF.
[5] Water
continues to be
supplied in
freeze cycle.
b) Controller Board
1. Defective.
1. See “II. 2. CONTROLLER
BOARD”.
a) Water Supply
Line
1. Water pressure too low
and water level in Water
Tank too low.
1. Check for recommended
pressure.
1. Dirty mesh filter or orifice
and water level in Water
Tank too low.
1. Clean.
2. Coil winding opened.
2. Replace.
b) Water Solenoid
Valve
3. Wiring to Water Valve.
3. Check for loose
connection or open, and
replace.
1. Water leaks.
1. Check connections for
water leaks, and repair.
c) Water System
2. Clogged.
2. Clean (See “V. 4.
ICEMAKING WATER
SYSTEM”).
1. Motor winding opened.
1. Replace.
2. Bearing worn out.
2. Replace.
[6] Water does not
circulate.
d) Pump Motor
3. Wiring to Pump Motor.
3. Check for loose
connection or open, and
replace.
E1CG4880210
65
Содержание IM-240AME
Страница 6: ...2 2 E1CG4880210 E1CG4880210 b IM 240DWME Water cooled b IM 240DWME Water cooled ...
Страница 7: ...3 3 E1CG4880210 E1CG4880210 c IM 240DSME Remote Air cooled c IM 240DSME Remote Air cooled ...
Страница 8: ...4 4 E1CG4880210 E1CG4880210 d IM 240XME Air cooled d IM 240XME Air cooled ...
Страница 9: ...5 5 E1CG4880210 E1CG4880210 e IM 240XWME Water cooled e IM 240XWME Water cooled ...
Страница 10: ...6 6 E1CG4880210 E1CG4880210 f IM 240XSME Remote Air cooled f IM 240XSME Remote Air cooled ...
Страница 11: ...7 7 E1CG4880210 E1CG4880210 g IM 240AME Air cooled g IM 240AME Air cooled ...
Страница 61: ...57 57 E1CG4880210 E1CG4880210 2 WIRING DIAGRAM 2 WIRING DIAGRAM a IM 240DME IM 240XME a IM 240DME IM 240XME ...
Страница 62: ...58 58 E1CG4880210 E1CG4880210 b IM 240DWME IM 240XWME b IM 240DWME IM 240XWME ...
Страница 63: ...59 59 E1CG4880210 E1CG4880210 c IM 240DSME IM 240XSME c IM 240DSME IM 240XSME ...
Страница 64: ...60 60 E1CG4880210 E1CG4880210 d IM 240AME d IM 240AME ...
Страница 93: ...89 89 E1CG4880210 E1CG4880210 Fig 54 Fig 54 ...