17
17
E1CG4880210
E1CG4880210
* Power: ON
* Reset Switch: ON
* Backup Timer counts up.
* Cube Control Thermistor
detects freeze cycle finished.
BACKUP TIMER
PUMP MOTOR ON
FAN
MOTOR ON
Freeze Cycle
Defrost Cycle
HOT GAS
VAL
VE ON
WA
TER
VAL
VE ON
Water Pan
OPEN
CLOSE
* Actuator
Toggle Switch moves
to FREEZE position.
* Bin Control Switch
tripped during
freeze cycle.
X 4
ON
X 1,2
OFF
X 3
OFF
X 4
OFF
X 1,2
OFF
X 3
OFF
X 4
ON
X 1,2
OFF
X 3
ON
X 4
ON
X 1,2
ON
X 3
OFF
* Cube Control Thermistor
detects defrost cycle finished.
X 4
ON
X 1,2
OFF
X 3
ON
X 4
ON
X 1,2
ON
X 3
ON
* Actuator
Toggle Switch moves
to DEFROST position.
* Bin Control Switch
tripped during
defrost cycle.
X 4
OFF
X 1,2
ON
X 3
OFF
1
2
4
3
4’
Adjustable
Relay Legend
X1 - Actuator Motor and Pump Motor
X2 - Hot Gas
Valve and Fan Motor
X3 - Water
Valve
X4 - Compressor
[c] SEQUENCE - LED INDICATORS ON/OFF PATTERN
[c] SEQUENCE - LED INDICATORS ON/OFF PATTERN
Содержание IM-240AME
Страница 6: ...2 2 E1CG4880210 E1CG4880210 b IM 240DWME Water cooled b IM 240DWME Water cooled ...
Страница 7: ...3 3 E1CG4880210 E1CG4880210 c IM 240DSME Remote Air cooled c IM 240DSME Remote Air cooled ...
Страница 8: ...4 4 E1CG4880210 E1CG4880210 d IM 240XME Air cooled d IM 240XME Air cooled ...
Страница 9: ...5 5 E1CG4880210 E1CG4880210 e IM 240XWME Water cooled e IM 240XWME Water cooled ...
Страница 10: ...6 6 E1CG4880210 E1CG4880210 f IM 240XSME Remote Air cooled f IM 240XSME Remote Air cooled ...
Страница 11: ...7 7 E1CG4880210 E1CG4880210 g IM 240AME Air cooled g IM 240AME Air cooled ...
Страница 61: ...57 57 E1CG4880210 E1CG4880210 2 WIRING DIAGRAM 2 WIRING DIAGRAM a IM 240DME IM 240XME a IM 240DME IM 240XME ...
Страница 62: ...58 58 E1CG4880210 E1CG4880210 b IM 240DWME IM 240XWME b IM 240DWME IM 240XWME ...
Страница 63: ...59 59 E1CG4880210 E1CG4880210 c IM 240DSME IM 240XSME c IM 240DSME IM 240XSME ...
Страница 64: ...60 60 E1CG4880210 E1CG4880210 d IM 240AME d IM 240AME ...
Страница 93: ...89 89 E1CG4880210 E1CG4880210 Fig 54 Fig 54 ...