10
3. RFH1-SSB(-HS)(-HSE) Reservoir Assembly Installation
The reservoir collects condensate water from the evaporators of both the refrigerator
and freezer. When the reservoir fills, the float switch activates the condensate pump.
Condensate water is pumped into the condensate pan for evaporation.
WARNING! Verify that the appliance is unplugged before installing the reservoir.
1) Remove the rear panel and rear cover.
2) Uncoil the suction hose and route to the
bottom of the unit. See Fig. 3.
3) Remove the reservoir and float switch from
the accessory bag. Uncoil the float switch
cable only.
NOTICE!
Do not remove the
nylon ties securing the plastic bag to
the reservoir and protecting the float
switch connection.
Next, plug the open
float switch connector into the pump.
See Fig. 4.
Fig. 3
Rear Panel
Rear Cover
Suction Hose
Fig. 4
4) Route the float switch cable with the suction
hose down to the bottom of the unit.
See Fig. 5.
Fig. 5
Suction Hose
Open Float Switch
Connector
Pump Motor
Suction Hose
Float Switch Cable
Float Switch/Reservoir Assembly
Pump Motor