The JA-112E Bus access module with RFID

The JA-112E Bus access module with RFID

1

MLU51310

The access module is a component of the 

JABLOTRON JA-100

system

.

Its modular architecture enables users to create a combination whose size of 
installation perfectly meets their needs. The device should be installed by a 
trained technician with a valid certificate issued by authorized distributor

.

The module comprises first control segment (1) and an RFID card / tag 

reader (3). The JA-192E segments can be used to extend the 
JA-112E unit by the required number of segments (the max. allowed amount 
is 20 on one unit).

Figure 1: 1 – control segment; 2 – segment buttons; 3 – backlit activation 

button with RFID reader; 4 – tabs for module opening

Figure 2: 5 – connector for control segments; 6 – BUS terminals, 

7 – production code; 8 – tamper contact

Installation  

1. Press the four tabs (4) on the sides one by one and release the module 

from the plastic base. 

2. When installing more control segments, first remove the socket cover on 

the 1

st

segment. 

3. Remove the transparent plastic cover from the segments (by levering 

on both sides of the segment near the buttons).

4. Always connect the segment wires to the connector of the previous 

segment and click them into each other (we recommend coiling the wires 
by turning the segment by 360° – this will prevent any possible damage to 
the wires between the plastic parts). Use this method to install all the 
required segments. Finally push the socket cover in. 

5. Push the 

cable through the plastic base and attach the base 

to the 

selected place together with the segments 

using screws.

If more

segments are required fix them onto the wall using screws as well.

6. Connect the BUS cable to the bus terminals (6). 

When connecting the module to the bus, 
always switch the power off.

7. Connect the segment wires to the internal connector of the module (5). 
8. Insert the RFID module into the base.
9. Proceed according to the control panel installation manual. Basic 

procedure:
a. When the device is switched on, the yellow backlit activation button 

(3) starts flashing repeatedly to indicate that the module has not 
been enrolled into the system. 

b. Go to the 

F-Link

software, select the required position in the 

Devices

window and launch the enrollment mode by clicking on 

the 

Enroll

option.

c.

Press the backlit activation button (3) – the access module 
is thus enrolled and the yellow LED indicator goes off.

10. When you have completed the installation, insert descriptive labels onto 

the segment transparent covers and close them, see figure 3. Label 
printing is a part of the F-Link software (

Devices 

window, at the module 

position –

Internal settings

).

Notes:

The module can also be enrolled to the system by entering its production 

code (7) in the F-Link software or using a bar code scanner. All numbers 
stated under the bar code shall be entered (1400-00-0000-0001).

To comply with the EN 50131-3 norm it is necessary to fix the cover tabs 

(4) by the screws from the accessories. In picture no 1 the cover tabs are 
displayed and marked by the arrows.

Figure 3: Insertion of a label into a control segment

Unit modifications 

If you need to change the unit’s individual segments, it is possible to 

separate them by levering the corresponding separating gaps from one side 
(sideways from the buttons). Make sure the system BUS is disconnected.

Setting the properties

Go to the 

Devices 

window in the F-Link software. When you are at the 

module position, use the 

Internal settings

option. The particular unit is 

displayed and it is possible to set its properties. Internal settings is separated 
into 2 basic tabs: 

Segments

and

Settings

.

It is possible to set the required functions for individual 

segments

(control 

of sections, section status signalling, alarm triggering, PG output control, PG 
output status signalling, etc.). More details are available in the F-Link 
software.

3

rd

optional setting tab 

Common segment

– settings and function 

description

A

common segment

(up to 2 of them allowed on one module unit) 

simulates the simultaneous pressing of several segments which are placed 
on this module and which control sections. In the

Segments

tab and select 

the specific segment function called 

Common segment A (B)

. Then in the 

new tab 

Common segment

select the segments which will be operated en 

bloc.

Note:

A module has to be equipped with a minimum of 3 segments otherwise 

this function cannot be used.

The 

selected sections

will all be set / unset after pressing a button on the 

common segment. 

If the states of the segments which are operated by the 

common segment

are mixed, then only the segments that need changing will be set / unset.

If partial setting is enabled for some segments, then the common segment 

respects this: 1

st

press = partially setting, 2

nd

press = full setting. It is not 

suitable to combine a common segment with a common section

The indication of the 

common segment

is: all segments unset = green, 

some set (partially set) = yellow, all sections fully set = red. 

In the Settings tab you can set all other module functions like acoustic 

signalling, backlight intensity, RFID reader mode, optical and acoustic 
indication, etc. Details related to settings can be found in the installation 
manual of the control panel and of course in the tooltips displayed by the
F-Link software.

Optical indication

Activation button

– indicates the system status. No light – sleep mode, 

green light – everything OK, green flashes – authorisation performed, red 
flashes – alarm, yellow light – fault, yellow flashes – not enrolled to the 
system, yellow double flash – Service mode.

Note:

The activation button doesn´t indicate module tamper activation in 

Service mode.

Segments

– don´t indicate a thing when Service mode is entered or when 

the segment has the function None. The optical indication of a PG segment 
can be inverted. 

Module can be preset to the following 6 indication levels:

1. Indicates permanently

– BUS modules indicate permanently only if 

an external power supply is connected. Without an external power 
supply it indicates the same as option 2. When the mains is restored 
module again indicates permanently.

2. Section / PG status change on keypad

– the module indicates 

when the section / PG status has been changed. The status change 
is indicated on the specific segment. Entrance delays and alarms are 
indicated by the whole module.

3. Section / PG status change on segment

– the module indicates 

when a section / PG output status has been changed. A segment 
status change, an entrance delay and an alarm is indicated on a 
specific segment. 

4. Segment status change on keypad

– The module indicates when 

the status of a segment has been changed (setting, unsetting, PG 
ON, PG OFF). The change of the status is indicated only on the 
specific segment.

5. Entrance delays / alarms on segment

– the  module indicates 

entrance delays and alarms on a specific segment.