B. Startup
WARNING
All parts are factory-adjusted. Improper adjustments may adversely affect safety,
performance, component life, and warranty coverage.
IMPORTANT
• At startup, there is a 2 1/2 minute delay before the compressor starts.
• On Dual Temp series, there is a delay of approximately 10 seconds between one
compressor start (i.e., freezer) and the next compressor start (i.e., refrigerator).
1) Open the front panel for access to the power switch—located on the front of the control
box. Make sure the power switch is in the "OFF" position.
2) Plug the appliance into the electrical outlet.
3) Move the power switch to the "ON" position to start the cool-down process. Close the
front panel.
4) Allow the appliance to cool down prior to loading it with food products.