48
CHART
NO.
COMPONENT
CHECK
REMEDY
[7]
Compressor
Resistance between terminals
Replace
Compressor Winding resistance (
Ω
)
Start Run
AE2360Y 22.37 11.49
AEA2410Y
21.29 7.00
AE2420ZK-SR
17.70 6.10
AE2432ZK
8.56
3.26
AEA2413Y
17.00 4.20
SC21CL 14.4 3.4
SC12CL 13.7 5.0
TL4G 18.2 15.1
FR8.5CL 12.0 7.3
AE1350Y-2 29.77 9.68
AE2390Y-2 17.40 5.40
AE2411Y-2SR 10.39 4.57
AE2428ZK-2SR 6.30 3.10
SC18CLX.2 9.5 2.6
Abnormal noise
Insufficient compression (discharge temp too low)
Replace if no gas leaks
Compressor electrical part defective
Replace
- Run/start capacitor ruptured/deformed
- Capacitor defective
Check resistance between terminals
Gradually reduces: No problem
0 from start: Defective
- Starter defective
Loose terminal, no conductivity, damaged
- Overload relay defective
Loose terminal, no conductivity, damaged
[8]
Condenser Fan Motor Open circuit
Correct
Locked (not rotating with voltage)
Replace
Abnormal noise
Burning smel
l
[9]
Interior Fan Motor
Open circuit
Correct
Locked (not rotating with voltage)
Replace
Abnormal noise
Burning smel
l
[10] Defrost Heater
Open circuit
Correct
Conductivity
Insulation resistance 1M
Ω
or more at 500V
Replace
[11] Thermal Fuse
Conductivity
Replace
Contact welding of relay
Replace relay
[12] Refrigeration Circuit
Discharge pressure: High
Replace capillary/expansion valve
Clogged
Suction pressure: Low (vacuum)
(Replace drier at same time)
[13] Refrigerant Leak
Discharge pressure: Low
Locate leakage and replace
Suction pressure: Low
(Replace drier at same time)
Compressor discharge pipe will not heat up
Compressor suction pipe will not cool down
[14] Air Filter
Clogged
Clean
[15] Sheath Heater *
Open circuit
Correct
Conductivity
Replace
Insulation resistance 1M
Ω
or more at 500V
Replace
[16] Thermostat *
Open circuit
Correct
Conductivity
Replace if not conductive
Air-Cooled Condenser Dirty fins
*Forced drain water evaporation model only
Содержание HFE-127MA-CHD
Страница 7: ...3 2 DIMENSIONS SPECIFICATIONS Representative standard models only a HRE 77MA CHD Model Code R262 C501 ...
Страница 8: ...4 b HRE 127MA CHD Model Code R263 C501 参考図 ホシザキ電機 2013 09 16 ...
Страница 9: ...5 c HRE 147MA CHD Model Code R264 C501 ...
Страница 10: ...6 d HRE 187MA CHD Model Code R265 C501 ...
Страница 11: ...7 e HFE 77MA CHD Model Code R266 C501 ...
Страница 12: ...8 f HFE 127MA CHD Model Code R267 C501 ...
Страница 13: ...9 g HFE 147MA CHD Model Code R268 C501 ...
Страница 14: ...10 h HFE 187MA CHD Model Code R269 501 ...
Страница 15: ...11 i HRFE 77MA CHD Model Code R281 C501 ...
Страница 16: ...12 j HRFE 127MAF CHD Model Code R282 C501 ...
Страница 17: ...13 k HRFE 147MAF CHD Model Code R283 C501 ...
Страница 18: ...14 l HRFE 187MAF CHD Model Code R284 C501 ...
Страница 20: ...16 d HFE 77MA CHD Model Code R266 C501 c HRE 187MA CHD Model Code R265 C501 ...
Страница 21: ...17 e HFE 127MA CHD Model Code R267 C501 HFE 147MA CHD Model Code R268 C501 f HFE 187MA CHD Model Code R269 501 ...
Страница 22: ...18 g HRFE 77MA CHD Model Code R281 C501 ...
Страница 23: ...19 h HRFE 127MAF CHD Model Code R282 C501 HRFE 147MAF CHD Model Code R283 C501 ...
Страница 24: ...20 i HRFE 187MAF CHD Model Code R284 C501 ...
Страница 26: ...22 k HRE 127MA CHD Model Code R263 C571 HRE 147MA CHD Model Code R264 C571 ...
Страница 27: ...23 l HRE 187MA CHD Model Code R265 C571 ...
Страница 28: ...24 m HFE 77MA CHD Model Code R266 C571 ...
Страница 29: ...25 n HFE 127MA CHD Model Code R267 C571 HFE 147MA CHD Model Code R268 C571 ...
Страница 30: ...26 o HFE 187MA CHD Model Code R269 C571 ...
Страница 57: ...53 HRFE 77MA refrigerator Defrost Thermistor Interior Thermistor ...