37
Defrosting stops automatically when the evaporator temperature reaches the defrost
termination temperature or when the defrost time runs out, or can be stopped manually.
If the evaporator sensor is not activated or in error, defrosting stops when the defrost time
runs out, or can be stopped manually.
Sensor Error Alarm
Alarm Code
Possible Cause
Operation
E1
Cabinet sensor (interior
thermistor) error
Compressor shuts down. When troubleshooting is
over, system recalculates compressor delay time.
E2
Evaporator sensor (defrost
thermistor) error
Defrost termination temperature is invalid.
Wiring Diagram
6
The system will begin defrosting according to the setting defrosing cycle , or
manually start defrosting. If evaporator sensor was activated, and the evaporator
sensor temperature is higher than the defrosting termination temperature, manually
start defrosting is not available.
Defrosting will stop when the evaporator temperature reaches the defrosting
termination temperature, or when the defrosting time run over, or manually stop the
defrosting.
If the evaporator sensor was not activated or when it is error, defrosting will be
stopped when the defrosting time run over, or it can be manually stopped.
Eighth
ǃ
Alarm of sensor error:
When the cabinet sensor errors happen, the controller will flashing indicate the
alarm code E1, with the buzzer doing nothing; close the compressor, when the
troubleshooting is over, system will recalculate the compressor delay time.
When the door-trip alarms, the controller will flashing indicate the alarm code
E2, with the buzzer ringing after running the time of "F5".
Alarm
code
Reason
Output mode
E1
Cabinet sensor
error
Close the compressor, when the
troubleshooting is over, system will
recalculate the compressor delay time.
E2
Evaporator error
The defrosting termination temperature is
invalid.
Ninth
ǃ
Wiring diagram:
Tenth
ǃ
Safety Rules:
Dangerous
ƾ
˖
1
ǃ
Strictly distinguish the sensor down-lead, power wire and output interface of the
relay, and prohibit wrong connections or overloading the relay.
Defrost
Interior
Содержание HFE-127MA-CHD
Страница 7: ...3 2 DIMENSIONS SPECIFICATIONS Representative standard models only a HRE 77MA CHD Model Code R262 C501 ...
Страница 8: ...4 b HRE 127MA CHD Model Code R263 C501 参考図 ホシザキ電機 2013 09 16 ...
Страница 9: ...5 c HRE 147MA CHD Model Code R264 C501 ...
Страница 10: ...6 d HRE 187MA CHD Model Code R265 C501 ...
Страница 11: ...7 e HFE 77MA CHD Model Code R266 C501 ...
Страница 12: ...8 f HFE 127MA CHD Model Code R267 C501 ...
Страница 13: ...9 g HFE 147MA CHD Model Code R268 C501 ...
Страница 14: ...10 h HFE 187MA CHD Model Code R269 501 ...
Страница 15: ...11 i HRFE 77MA CHD Model Code R281 C501 ...
Страница 16: ...12 j HRFE 127MAF CHD Model Code R282 C501 ...
Страница 17: ...13 k HRFE 147MAF CHD Model Code R283 C501 ...
Страница 18: ...14 l HRFE 187MAF CHD Model Code R284 C501 ...
Страница 20: ...16 d HFE 77MA CHD Model Code R266 C501 c HRE 187MA CHD Model Code R265 C501 ...
Страница 21: ...17 e HFE 127MA CHD Model Code R267 C501 HFE 147MA CHD Model Code R268 C501 f HFE 187MA CHD Model Code R269 501 ...
Страница 22: ...18 g HRFE 77MA CHD Model Code R281 C501 ...
Страница 23: ...19 h HRFE 127MAF CHD Model Code R282 C501 HRFE 147MAF CHD Model Code R283 C501 ...
Страница 24: ...20 i HRFE 187MAF CHD Model Code R284 C501 ...
Страница 26: ...22 k HRE 127MA CHD Model Code R263 C571 HRE 147MA CHD Model Code R264 C571 ...
Страница 27: ...23 l HRE 187MA CHD Model Code R265 C571 ...
Страница 28: ...24 m HFE 77MA CHD Model Code R266 C571 ...
Страница 29: ...25 n HFE 127MA CHD Model Code R267 C571 HFE 147MA CHD Model Code R268 C571 ...
Страница 30: ...26 o HFE 187MA CHD Model Code R269 C571 ...
Страница 57: ...53 HRFE 77MA refrigerator Defrost Thermistor Interior Thermistor ...