IV. BEFORE CALLING A SERVICE AGENT

IMPORTANT

1. If the temperature display window on the 

operation panel indicates an error code 

or something seems wrong with the unit, 

check for possible causes according to the 

following instructions. If the problem still 

exists, immediately contact an authorized 

Hoshizaki service company.

2. When contacting a service company, let them 

know the model name, serial number, date of 

installation (see warranty card) and state of 

the trouble.

3. Do not attempt to repair the unit yourself.

1.  TROUBLES WITH ERROR CODE 

INDICATION

When the temperature display window on the 

operation panel flashes alternately between an error 

code and the cabinet temperature, check the error 

code and follow the instructions below.

1) If one of the following error codes is displayed, 

immediately contact an authorized Hoshizaki 

service company.

* Do not use the following items. They could damage 

painted or plastic surfaces:

  Polishing powder, alcohol, thinner, benzine, acidic 

or alkaline detergent, hot water, petroleum, soap 

powder, metal scourer or brush, etc.

  Especially detergent to clean grease on ventilator 

or microwave.

 

Fig. 14

Air Filter

(2) Attach to condenser

Magnet

Front Panel

Condenser

(1) Hook on condenser bottom

Note:  Some solutions other than the above may 

also damage painted or plastic surfaces. 

Immediately stop using such solutions if 

they cause any problems.

* The door gasket and its contact surface get 

soiled easily. Clean every surface of these parts 

thoroughly. Remnants of food will accelerate aging.

* Use a cloth to wipe off any water staying inside the 

cabinet.

2. AIR FILTER

IMPORTANT

To prevent deformation, do not wash the air 

filter with hot water above 40°C.

Plastic  mesh  air  filters  remove  dirt  or  dust  from  the 

air, and keep the condenser from getting clogged. 

If the filters get clogged, the refrigerator/freezer’s  

performance will be reduced.

Check the filter at least twice a month. When 

clogged, use warm water and a neutral cleaner to 

wash  the  filter.  Do  not  operate  the  unit  with  the  air 

filter removed, or the condenser will get clogged, 

resulting in failure.

1) Open the front panel, and remove the air filter. To 

prevent injury, do not touch the condenser fins 

directly.

2) Wash the air filter carefully with cold or warm 

water containing the proper amount of neutral 

cleaner. Rinse and dry the air filter thoroughly.

3) To refit the air filter, first hook it on the bottom 

of  the  condenser,  then  attach  the  air  filter  to  the 

condenser.

4) Close the front panel.

Fig. 13

Fig. 12

Содержание FTC-120 A Series

Страница 1: ...n as they are intended to provide the installer user with essential information for the proper installation and the continued safe use and maintenance of the product Please preserve this booklet for a...

Страница 2: ...HELF SHELF CLIP AND SHELF HOLDER 9 b RAIL customized 10 4 ELECTRICAL CONNECTIONS 10 5 DRAIN CONNECTION 11 6 OPERATION 11 a START UP 12 b CABINET TEMPERATURE SETTING 12 c RAPID REFRIGERATION 13 d DEFRO...

Страница 3: ...1 1 2 I 1 2 900mm 1200 1500mm 1800mm a 2 2 4 4 6 6 b 8 8 16 16 24 24 c 5 0 10 0 15 0 d 5 5 4 4 4 4 1 2 II 1 5 43 2 9 12 15 18 cm 50cm 38 10cm 3 50cm 1 1 2 RTC FTC 90 A 5...

Страница 4: ...2 6 7 b 1 2 8 2 1 45 2 1 4 2 3 5 4 5 6 7 8 3 a 2 5cm...

Страница 5: ...3 2 1 1 2 8 4 10A 10 5 1 2 A A 9 1 2 3 5cm 5cm 4 5cm...

Страница 6: ...4 15 16 17 18 30 19 a 1 2 3 5 b 3 18 1 2 3 6 12 7 25 30 10 250V 10A 5cm 20mm 5 6 6 1 2 3 LPG 4 5 60kg 6 7 8 9 1 10 11 12 13 14...

Страница 7: ...5 4 c 1 5 2 5 11 d 6 dF 6 e 1 2 3 III 1 2 3 40 1 12 13 2 40 1...

Страница 8: ...6 2 3 4 2 1 14 IV 1 2 3 1 1 E3 E8 E9 EA ED 2 E1 1 2 3 E2 1 5 43 2 E4 E7 1 2 E1 E2 E4 E7 2 1 1 2 3 2 1 43 2 3 4 5 6 7 8 3...

Страница 9: ...7 1 2 4 1 2 3 5 1 2 V VI XK06 015 00212 RTC FTC 180SDA RTC FTC 180SDA GB 4706 1 SB 10424 GB T 21001 2 GB T 21001 3 JB T 7244 RTC FTC 180SDA GB 4706 1 GB 4706 13 GB 4343 1 GB 17625 1...

Страница 10: ...1 Pb Hg Cd Cr PBB PBDE K MD 270AA KMD 270AWA DBF 40SAC HRE B HFE B HRFE B HRE B HFE B HRFE B HIH YA RTC S A FTC S A KMD AWA HIH YA IM 220AA 2 3 GB T 26572 GB T 26572 SJ T 11364...

Страница 11: ...les located at the bottom of the unit 2 ACCESSORIES Width 900mm 1200 1500mm 1800mm a Shelf 2 2 4 4 6 6 b Shelf clip 8 8 16 16 24 24 c Shelf holder 5 0 10 0 15 0 d Leg 5 5 4 4 4 4 Note 1 Numbers in par...

Страница 12: ...m clearance from the wall at the side of the machine compartment to prevent overloading and damaging the refrigeration circuit Fig 3 Air Outlet Air Inlet Min 50cm 4 Mount the rear legs or casters in t...

Страница 13: ...b RAIL customized To attach the rail 1 push the rail hook backwards to fit into the square hole in the rear shelf post and 2 push the rail hook down to fit into the square hole in the front shelf pos...

Страница 14: ...drain outlet 3 To prevent backflow do not connect the flexible hose directly to the sewer system An air gap of at least 5 cm should be between the end of the flexible hose and the floor drain 5 The dr...

Страница 15: ...oods may dry up or give their smells to other foods 15 Foods containing acetic acid or yeast should be wrapped up in a plastic film Otherwise they may accelerate corrosion of the evaporator and copper...

Страница 16: ...move the stored foods into another refrigerator freezer 2 Unplug the unit or disconnect the main power supply 3 When preparing the unit for long storage clean the cabinet interior and door gaskets dry...

Страница 17: ...r 2 Attach to condenser Magnet Front Panel Condenser 1 Hook on condenser bottom Note Some solutions other than the above may also damage painted or plastic surfaces Immediately stop using such solutio...

Страница 18: ...ir filter not clean 6 Door s left open 7 Warm or hot foods inside 8 Unit in defrost process The cabinet temperature may rise temporarily during defrost cycle but will not affect the foods inside 3 Con...

Страница 19: ...na Tel 86 21 5228 8181 Fax 86 21 5228 0113 Hoshizaki Hong Kong Co Limited Unit 1201 1202 12 F Tamson Plaza 161 Wai Yip Street Kwun Tong Kowloon HK Tel 852 2866 2108 Fax 852 2866 2109 Hoshizaki Singapo...

Отзывы: