ENGLISH
11
* This refrigerator/freezer must be plugged into
the separated power receptacle which is readily
accessible and has enough capacity. The
maximum allowable voltage variation should not
exceed ± 10 percent of the nameplate rating. See
the nameplate.
* If the supply cord and the plug should need to be
replaced, it should only be done by a qualified
service engineer to avoid any danger.
5. DRAIN CONNECTIONS
CAUTION
Be sure to connect the drain hoses properly.
Otherwise water leaks from the drain hoses
may damage the surroundings (property).
1) Connect the accessory flexible hose to the drain
outlet located at the bottom of the unit.
2) Bend the flexible hose into a trap as shown. Use
the accessory cable straps to fix the flexible hose
tightly on the bottom of the unit (mounting holes
provided).
IMPORTANT
1. To prevent disconnection, be sure to use the
cable straps to secure the flexible hose in
place.
2. The drain line should be as short and straight
as possible, sloped downward, and located
below the drain outlet.
3. To prevent backflow, do not connect the
flexible hose directly to the sewer system. An
air gap of at least 5 cm should be between
the end of the flexible hose and the floor
drain.
5. The drain connections are required to
prevent ambient air from causing excessive
frost build up on the evaporator, resulting in
reduction of the refrigeration capacity.
6. Do not let water drain directly onto the floor
before running into the drain. Foreign matter
on the floor may mix into the water and clog
the drain, or the water could run in a wrong
direction.
6. OPERATION
IMPORTANT
1. B e c a r e f u l n o t t o w e t t h e m a c h i n e
compartment. This might cause failure or
electric shock hazard.
2. To prevent electric shock, do not touch the
attachment plug with wet hands.
Flexible Hose
Water Surface
Min. 5cm
Commercial Elbow
(not provided)
Water Surface
Min. 5cm
Commercial Pipe
20mm DIA
(not provided)
Cable Strap
Flexible Hose
Drain Outlet
(defrost water)
A
Cable Strap
Detail A (front view)
Fig. 9
4. If the flexible hose is too short to reach the
floor drain, connect a commercial pipe to the
flexible hose. Be sure to allow an air gap of
at least 5 cm between the end of the drain
pipe and the floor drain.