![Hoshizaki F-2000MLH Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/hoshizaki/f-2000mlh/f-2000mlh_service-manual_2165109008.webp)
8
F-2000MRH-C
We reserve the right to make changes in specifications and design without prior notice.
AC SUPPLY VOLTAGE
208-230/60/1 (3 wire with neutral for 115V)
COMPRESSOR
240 V
10.8 RLA
96 LRA
GEAR MOTOR
120 V
5.6 FLA
0.54 HP
FAN MOTOR REMOTE
120 V
3A
MAX
OTHER
120 V
0.03A
MAXIMUM FUSE SIZE
30 A
MAX. HACR BREAKER (USA ONLY)
30 A
MAX. CIRC. BREAKER (CANADA ONLY)
30 A
MINIMUM CIRCUIT AMPACITY
30 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
lbs./day ( kg/day )
70
*1715 (778)
1660 (753)
1630 (739)
Reference without *marks
80
1595 (723)
1560 (708)
1530 (694)
90
1500 (680)
*1490 (676)
1435 (651)
100
1410 (640)
1380 (626)
*1270 (576)
SHAPE OF ICE
Cubelet
ICE QUALITY
Approx. 80%, Ice (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY
N/A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
2870 (4.6)
2860 (4.0)
POTABLE WATER
179 (12)
205 (12)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)
30" x 27-1/2" x 34-7/16" (762 x 699 x 874mm)
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear)
WEIGHT
Net 310 lbs. ( 140 kg ), Shipping 342 lbs. ( 155 kg )
CONNECTIONS - ELECTRIC
Permanent - Connection
- WATER SUPPLY
Inlet 1/2" FPT
- DRAIN
Outlet 3/4" FPT
- REFRIGERATION
Discharge line 1-1/16-12 UNF Fitting (#10 AEROQUIP)
CIRCUIT
Liquid line 5/8-18 UNF Fitting (#6 AEROQUIP)
ICE MAKING SYSTEM
Auger type
HARVESTING SYSTEM
Direct Driven Auger ( 400 W Gear Motor )
ICE MAKING WATER CONTROL
Float Switch
COOLING WATER CONTROL
N/A
BIN CONTROL SYSTEM
Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR
Hermetic, Model CS20-K6E-PFV
CONDENSER
Air-cooled Remote Condenser unit URC-20F Recommended
EVAPORATOR
Copper Tube on Cylinder
REFRIGERANT CONTROL
Thermostatic Expansion Valve
Condensing Pressure Regulator on URC-20F
REFRIGERANT CHARGE
R-404A,
14 lb. 9 oz.
(6600g)
(Ice Maker: 6 lb. 14 oz., Cond. Unit: 7 lb. 11 oz. )
DESIGN PRESSURE
High 460 PSIG, Low 290 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-off Relay
COMPRESSOR PROTECTION
Internal Protector
GEAR MOTOR PROTECTION
Manual Reset Circuit Breaker & Thermal Protector
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch and Timer
BIN CONTROL PROTECTION
Manual Reset Spout Control
ACCESSORIES -SUPPLIED
Spare Fuse
-REQUIRED
Ice Storage Bin
OPERATING CONDITIONS
VOLTAGE RANGE
187-253 V
AMBIENT TEMP.
45-100° F
WATER SUPPLY TEMP.
45-90° F
WATER SUPPLY PRESSURE
10-113 PSIG
Содержание F-2000MLH
Страница 13: ...13 2 CONDENSER UNIT URC 20F...
Страница 15: ...15 II GENERAL INFORMATION 1 CONSTRUCTION F 2000MWH C...
Страница 16: ...16 F 2000MRH C F 2000MRH3 C...
Страница 17: ...17 F 2000MLH C...
Страница 19: ...19 F 2000MRH3 C...
Страница 20: ...20 F 2000MLH C...
Страница 21: ...21 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 2000MWH C...
Страница 22: ...22 F 2000MRH C F 2000MRH3 C...
Страница 23: ...23 F 2000MLH C...
Страница 24: ...24 2 WIRING DIAGRAMS F 2000MWH C...
Страница 25: ...25 F 2000MRH C...
Страница 26: ...26 F 2000MRH3 C...
Страница 27: ...27 F 2000MLH C...
Страница 29: ...29 b When Reservoir has been filled Gear Motor starts immediately...
Страница 30: ...30 c Compressor starts F 2000MLH C only two solenoid valves open about 60 sec after Gear Motor starts...
Страница 32: ...32 e Low Water Except Water cooled Model where Compressor will operate intermittently...
Страница 38: ...38...
Страница 68: ...68...