![Hoshizaki F-2000MLH Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/hoshizaki/f-2000mlh/f-2000mlh_service-manual_2165109041.webp)
41
5. PERFORMANCE DATA
F-2000MWH
We reserve the right to make changes in specifications and design without prior notice.
APPROXIMATE
Ambient
Water Temp. (F)
ICE PRODUCTION
Temp. (F)
PER 24 HR.
70
2030
(921)
1955
(887)
1915
(869)
80
1875
(851)
1835
(832)
1795
(814)
90
1760
(798)
1730
(785)
1685
(764)
lbs./DAY ( kg/day)
100
1650
(748)
1615
(733)
1500
(680)
APPROXIMATE ELECTRIC
70
2490
--
2510
--
2545
--
CONSUMPTION
80
2490
--
2510
--
2545
--
90
2490
--
2510
--
2545
--
watts
100
2490
--
2510
--
2545
--
APPROXIMATE WATER
70
981
(3.71)
1266
(4.79)
2057
(7.79)
CONSUMPTION PER 24 HR.
80
1023
(3.87)
1319
(4.99)
2163
(8.19)
(TOTAL)
90
1062
(4.02)
1374
(5.20)
2278
(8.62)
gal. / day (m
3
/day)
100
1105
(4.18)
1442
(5.46)
2513
(9.51)
EVAPORATOR OUTLET TEMP.
70
11
(-12)
11
(-12)
11
(-12)
°F (°C)
80
11
(-12)
11
(-12)
11
(-12)
90
11
(-12)
11
(-12)
11
(-12)
100
11
(-12)
11
(-12)
11
(-12)
HEAD PRESSURE
70
262
(18.4)
263
(18.5)
265
(18.6)
80
262
(18.4)
263
(18.5)
265
(18.6)
90
262
(18.4)
263
(18.5)
265
(18.6)
PSIG (kg/sq.cmG)
100
262
(18.4)
263
(18.5)
265
(18.6)
SUCTION PRESSURE
70
26
(1.8)
27
(1.9)
28
(2.0)
PSIG (kg/sq.cmG)
80
26
(1.8)
27
(1.9)
28
(2.0)
90
26
(1.8)
27
(1.9)
28
(2.0)
100
26
(1.8)
27
(1.9)
28
(2.0)
WATER FLOW FOR CONDENSER
97 gal/h (AT 100°F /WT 90°F)
HEAT OF REJECTION FROM CONDENSER
15530 BTU/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR
2910 BTU/h (AT 90°F /WT 70°F)
Note: The data without *marks should be used for reference.
50
70
90
Содержание F-2000MLH
Страница 13: ...13 2 CONDENSER UNIT URC 20F...
Страница 15: ...15 II GENERAL INFORMATION 1 CONSTRUCTION F 2000MWH C...
Страница 16: ...16 F 2000MRH C F 2000MRH3 C...
Страница 17: ...17 F 2000MLH C...
Страница 19: ...19 F 2000MRH3 C...
Страница 20: ...20 F 2000MLH C...
Страница 21: ...21 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 2000MWH C...
Страница 22: ...22 F 2000MRH C F 2000MRH3 C...
Страница 23: ...23 F 2000MLH C...
Страница 24: ...24 2 WIRING DIAGRAMS F 2000MWH C...
Страница 25: ...25 F 2000MRH C...
Страница 26: ...26 F 2000MRH3 C...
Страница 27: ...27 F 2000MLH C...
Страница 29: ...29 b When Reservoir has been filled Gear Motor starts immediately...
Страница 30: ...30 c Compressor starts F 2000MLH C only two solenoid valves open about 60 sec after Gear Motor starts...
Страница 32: ...32 e Low Water Except Water cooled Model where Compressor will operate intermittently...
Страница 38: ...38...
Страница 68: ...68...