46
F-2000MRH3-C
APPROXIMATE
Ambient
Water Temp. (F)
ICE PRODUCTION
Temp. (F)
PER 24 HR.
70
1725
(782)
1685
(764)
1650
(748)
80
1615
(733)
1580
(717)
1545
(701)
90
1515
(687)
1525
(692)
1450
(658)
lbs./DAY ( kg/day)
100
1420
(644)
1390
(631)
1275
(578)
APPROXIMATE ELECTRIC
70
2970
--
2975
--
2980
--
CONSUMPTION
80
2980
--
2985
--
2990
--
90
2995
--
3000
--
3040
--
watts
100
3080
--
3125
--
3165
--
APPROXIMATE WATER
70
207
(782)
202
(764)
198
(748)
CONSUMPTION PER 24 HR.
80
194
(733)
190
(717)
186
(701)
90
182
(687)
183
(692)
174
(658)
gal. / day (l/day)
100
170
(644)
167
(631)
153
(578)
EVAPORATOR OUTLET TEMP
70
12
(-11)
12
(-11)
14
(-10)
°F (°C)
80
14
(-10)
14
(-10)
14
(-10)
90
14
(-10)
14
(-10)
14
(-10)
100
14
(-10)
14
(-10)
14
(-10)
HEAD PRESSURE
70
222
(15.6)
222
(15.6)
222
(15.6)
80
225
(15.8)
225
(15.8)
225
(15.8)
90
228
(16.0)
228
(16.0)
228
(16.0)
PSIG (kg/sq.cmG)
100
262
(18.4)
262
(18.4)
262
(18.4)
SUCTION PRESSURE
70
25
(1.7)
25
(1.7)
25
(1.7)
PSIG (kg/sq.cmG)
80
25
(1.8)
25
(1.8)
25
(1.8)
90
26
(1.8)
26
(1.8)
26
(1.8)
100
29
(2.0)
29
(2.0)
29
(2.0)
CONDENSER VOLUME
214 cu in
HEAT OF REJECTION FROM CONDENSER16750 BTU/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM COMPRESS 3000 BTU/h (AT 90°F /WT 70°F)
Note: The data without *marks should be used for reference.
50
70
90
We reserve the right to make changes in specifications and design without prior notice.
Содержание F-2000MLH
Страница 13: ...13 2 CONDENSER UNIT URC 20F...
Страница 15: ...15 II GENERAL INFORMATION 1 CONSTRUCTION F 2000MWH C...
Страница 16: ...16 F 2000MRH C F 2000MRH3 C...
Страница 17: ...17 F 2000MLH C...
Страница 19: ...19 F 2000MRH3 C...
Страница 20: ...20 F 2000MLH C...
Страница 21: ...21 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 2000MWH C...
Страница 22: ...22 F 2000MRH C F 2000MRH3 C...
Страница 23: ...23 F 2000MLH C...
Страница 24: ...24 2 WIRING DIAGRAMS F 2000MWH C...
Страница 25: ...25 F 2000MRH C...
Страница 26: ...26 F 2000MRH3 C...
Страница 27: ...27 F 2000MLH C...
Страница 29: ...29 b When Reservoir has been filled Gear Motor starts immediately...
Страница 30: ...30 c Compressor starts F 2000MLH C only two solenoid valves open about 60 sec after Gear Motor starts...
Страница 32: ...32 e Low Water Except Water cooled Model where Compressor will operate intermittently...
Страница 38: ...38...
Страница 68: ...68...