© 1995,1997 Directed Electronics, Inc. Vista, CA
18
N432 1-98.PM6
OPERATING-SETTINGS LEARN ROUTINE™
Many of the operating settings of this unit are programmable. They can be changed whenever necessary through a
computer-based Learn Routine™. The Valet
®
/program push-button switch, plugged into the blue port is used together
with a programmed transmitter to change the settings. To program settings remember: Door, Key, Choose, Transmit
and Release.
1.
Door
Open a door. Either the H1/5 GREEN or the H1/7 VIOLET door
trigger wire must be connected for the control unit to “see” an
open door.
2.
Key
Turn the ignition on and then back off. The H1/9 YELLOW
switched ignition input must be connected.
3.
Choose
Within 15 seconds, press and release the Valet
®
/Program
button the number of times corresponding to the number of
the desired feature (see the chart below). The one chirp
settings below are the factory default settings, except where
indicated by bold text.
Feature Number
One-chirp Setting
Two-chirp Setting
1
Active arming
Passive arming
2
Arm/disarm chirps on
Arm/disarm chirps off
3
Ignition-controlled door locks
Standard door locks
4
Active locking only
Passive locking
5
Panic with ignition on
No panic with ignition on
6
0.8 second door lock pulses
3.5 second door lock pulses
7
Forced passive arming on
Forced passive arming off
8
Automatic engine disable on
Automatic engine disable off
9
Double pulse unlock off
Double pulse unlock on
10
Code-Hopping™ on
Code-Hopping™ off
11
Siren
Horn honk