Installa�on: 

Ceiling

 

Step 1. Mark and drill desired loca�on on moun�ng surface. 

                             Secure the hood with 4 (M10) expansion bolts 

                             (not provided) directly to a structural member; 

                             thread onto a NPT 3/4 inch conduit.

 

Step 2. Hang the fixture onto the hinge hook of the hood. 

                             Connect supply wires to luminaire wire leads

                             (or Wago connectors provided)

 

Step 3. Close driver housing, making sure that all wires are 

                             safely inside driver. Tighten three cap�ve closing 

                             screw (M6) to (6 N-m).

               

Note: All installation must refer to "NPT Assembly 

                             Instructions" to prevent water leakage.

Bracket

 

Step 1. Secure the bracket and hood with 4 (M10) expansion  

 

              bolts (not provided) directly to a structural member;

 

              make sure the hinge is located as marked, 

(See Figure 1a.)

 

              Adjust the angle (6x15°) of the bracket and fix the  

 

              posi�on with M5 screws (provided).

 

Step 2. Hang the fixture onto the hinge hook of the hood.  

 

              Connect supply wires to luminaire wire leads (or Wago  

 

              connectors).

 

Step 3. Close driver housing, making sure that all wires are safely  

 

              inside driver. Tighten three cap�ve closing screw (M6) to  

 

              (6 N-m).

               

Note: All installation must refer to "NPT Assembly 

                             Instructions" to prevent water leakage.

Step 1

Figure 1a

Step 2

Step 3

Step 1

Step 2

Step 3

Expansion bolts

(Washers required ) M10

3/4’’ NPT

Expansion bolts

( Washers required ) M10

Soket head cap screw M5

Soket head cap screw M10

3/4’’ NPT

Angle 0-90° Adjustable (6X15°)

Содержание ETG-HHR

Страница 1: ...her wiring methods in accordance with Ar cle 502 in the Na onal Electrical Code NFPA 70 Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply Turn off the power when you perform any maintenance Verify that supply voltage is correct by comparing it with the luminaire label informa on Make all electrical and grounded connec ons in accordance with the Na onal...

Страница 2: ...o suitable conduit 3 Inset the wire from outside through the conduit and the entry hole of Tank then connect to Terminal Block 4 Introduce the wires of branch circuit as following Black wiring connects to Line White wiring connects to Neutral Green wiring connects to Ground 5 Re a ach the Tank Cover and ghten it by eight M6 hexagon bolts of Tank Cover with torque value 6 N m 6 Check the ghtness of...

Страница 3: ...ket Step 1 Secure the bracket and hood with 4 M10 expansion bolts not provided directly to a structural member make sure the hinge is located as marked See Figure 1a Adjust the angle 6x15 of the bracket and fix the posi on with M5 screws provided Step 2 Hang the fixture onto the hinge hook of the hood Connect supply wires to luminaire wire leads or Wago connectors Step 3 Close driver housing making ...

Страница 4: ...he M5 set screw Make sure the gasket of the adapter is properly inserted into the slot Step 2 Hang the hood onto the adapter align as marked Step 3 Rotate the hood clockwise and secure the adapter with M5 screws provided to 5 N m Step 4 Hang the fixture onto the hinge hook of the hood Connect supply wires to luminaire wire leads or Wago connectors Step 5 Close driver housing making sure that all wi...

Страница 5: ...ot Step 3 Hang the hood onto the adapter align as marked Step 4 Rotate the hood clockwise and secure the adapter with M5 screws provided to 5 N m Step 5 Hang the fixture onto the hinge hook of the hood and Connect supply wires to luminaire wire leads or Wago connectors Step 6 Close driver housing making sure that all wires are safely inside driver Tighten three cap ve closing screw M6 to 6 N m Note...

Страница 6: ...all parts are properly assembled Electrically check to make sure that all connec ons are clean and ght NPT Assembly Instruc ons Step 1 Inspect port and fi ng to ensure that both are free of contaminants and excessive burrs and nicks Step 2 Apply a stripe of an anaerobic liquid pipe sealant around the male threads leaving the first two threads uncovered If no liquid sealant is available wrap Teflon ta...

Отзывы: