Connector for USB communication with a personal computer

Chapter 2  Information of the DS-71      

2.3  Names and Functions    

DS-71

5

2.3.2 Display

Setting mode

Error No.,

Data No.,

Date

HOLD 

indicator

Measuring 

parameter

Calibration 

status

Electrode status icon

Printer connecting icon

Data memory icon

Temperature

USB icon

Measurement 

unit

Содержание DS-71

Страница 1: ...Instruction Manual COND METER DS 71...

Страница 2: ...attributable to repair or modification by any person not authorized by HORIBA Ltd Any malfunction or damage attributable to the use in an environment not specified in this manual Any malfunction or d...

Страница 3: ...ymbol with underbar shown on the product or accompanying documents indicates the product requires appropriate treatment collection and recycle for waste electrical and electronic equipment WEEE under...

Страница 4: ...ese limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio fre...

Страница 5: ...is to be limited to the most extreme situations This indicates a potentially hazardous situation which if not avoided could result in death or serious injury This indicates a potentially hazardous si...

Страница 6: ...essages WARNING Do not use an unspecified AC adapter Otherwise it may heat up or be ignited resulting in a fire or an accident Do not disassemble or modify the meter Otherwise it may heat up or be ign...

Страница 7: ...the cable it may cause a breakage The touch panel is capacitance type Make sure to turn OFF the power before cleaning the panel If you wipe it with the power ON it may cause instrument malfunction RS...

Страница 8: ...nual This interprets the necessary points for correct operation and notifies the important points for handling the instrument This indicates the part of where to refer the information HINT This indica...

Страница 9: ...nd 10 3 1 2 Electrode Connection 11 3 1 3 Connecting the Power Source 12 3 1 4 Connecting and Setting the Printer 13 3 1 5 Connecting the Personal Computer 14 3 2 Settings 15 3 2 1 Temperature Compens...

Страница 10: ...nting 46 3 5 Data Operation 49 3 5 1 Data Memory of Measurement Value 49 3 5 2 Memory Data Display 50 3 5 3 Memory Data Printing 51 Chapter 4 Maintenance and Troubleshooting 53 4 1 Conductivity Electr...

Страница 11: ...mized for laboratory measurement and allows you to measure conductivity resistivility salinity and TDS It provides a comfortable measurement environment with the design easy to wipe clean without roug...

Страница 12: ...Information of the DS 71 2 1 Measurement Items 2 HORIBA Chapter 2 Information of the DS 71 2 1 Measurement Measurement item DS 71 Conductivity Salinity Resistivity TDS Total Dissolved Solids Temperat...

Страница 13: ...1 s package includes the following Electrodes are required for the measurement in addition to this package If you want to buy an electrode contact HORIBA sales representative Product Quantity Main uni...

Страница 14: ...mes and Functions 4 HORIBA 2 3 Names and Functions 2 3 1 Names of Each Part Stand arm Stand base Operation key Stopper Display CH2 reference electrode CH2 measurement electrode CH2 temperature electro...

Страница 15: ...2 Information of the DS 71 2 3 Names and Functions DS 71 5 2 3 2 Display Setting mode Error No Data No Date HOLD indicator Measuring parameter Calibration status Electrode status icon Printer connect...

Страница 16: ...ing mode DATA key Enters the data operation mode Printouts calibration value SET key Enters the setting mode Cancels the setting values of the setting mode MODE key Toggles the measurement items key k...

Страница 17: ...Information of the DS 71 2 4 Measurement MEAS Flow Chart DS 71 7 2 4 Measurement COND measurement MODE key Resistivity measurement MODE key Salinity measurement MODE key TDS measurement MODE key MEAS...

Страница 18: ...0 cm Input range 0 700 to 1 300 Salinity unit setting PPT key Temperature compensation function setting ATC MTC key Automatic data memory setting key ON OFF key Sample ID setting Automatic printout se...

Страница 19: ...Chapter 2 Information of the DS 71 2 6 Data DATA Flow Chart DS 71 9 2 6 Data Data memory key Data display key DATA Flow Chart...

Страница 20: ...ation 10 HORIBA Chapter 3 Basic Operation 3 1 Preparation 3 1 1 Assembling the Electrode Stand 1 Attach the stand shaft to the stand base 2 Attach the stopper and the stand arm to the stand shaft Stan...

Страница 21: ...trode CH2 temperature electrode Electrode connector 1 Insert the groove of electrode plug by fitting it with the socket pin of the instrument If the pin and groove are misaligned do not insert the plu...

Страница 22: ...Insert the temperature connector into the jack socket on the instrument CH1 temperature electrode If the temperature connector is unconnected or the connection is wrong the MTC set temperature is dis...

Страница 23: ...nt Printer connector The following printer is possible Printer CITIZEN CBM 910 24RJ120 V plain paper type Parts No 3014030146 CITIZEN CBM 910 24RJ230 V plain paper type Parts No 3014030147 Optional pr...

Страница 24: ...omputer Personal computer communication connector Use proprietary cables to connect with a personal computer Proprietary cable Parts name USB cable 1 m Parts No 3200373941 Make sure that the transfer...

Страница 25: ...ress the SET key during setting or after pressing the ENTER key the settings are cancelled 3 2 1 Temperature Compensation Function Setting You can perform temperature compensation for conductivity ele...

Страница 26: ...tic Temperature Compensation ATC the instrument detects the solution temperature When the temperature sensor is connected the current tempera ture of the solutions is displayed automatically If the se...

Страница 27: ...easurement screen and press the or key to enter the auto data memory setting screen 2 Press the ENTER key to enter the auto data memory change screen 3 Press the or key to change ON or OFF and press t...

Страница 28: ...ata at the data memory and it allows you to search data easily 1 Press the SET key on the measurement screen and press the or key to enter the sample ID setting screen 2 Press the ENTER key to enter t...

Страница 29: ...ong S cm S m and mS cm FIX When mS cm FIX is selected the unit is fixed to mS cm 1 Press the SET key on the measurement screen and press the or key to enter the conductivity unit setting screen 2 Pres...

Страница 30: ...to 10 00 The default is 2 00 1 Press the SET key on the measurement screen and press the or key to enter the conductivity unit setting screen 2 Press the ENTER key to enter the conductivity tem perat...

Страница 31: ...ant written on the label of the electrode 1 Press the SET key on the measurement screen and press the or key to enter the conductivity cell constant setting screen 2 Press the ENTER key to enter the c...

Страница 32: ...ing range 0 700 to 1 300 3 2 7 Salinity Unit Setting You can select the unit of salinity measurement between PPT and 1 Press the SET key on the measurement screen and press the or key to enter the sal...

Страница 33: ...executed at the following occasions You perform data memory during measurement Calibration or check is completed in the calibration mode 1 Press the SET key on the measurement screen and press the or...

Страница 34: ...screen helps you to use the instrument in good conditions LCD Check You can check the LCD 1 Press the SET key on the measurement screen and press the or key to enter the maintenance screen 2 Press the...

Страница 35: ...ecting screen Printer Test You can check the printer connection and printout operation 1 Press the SET key on the measurement screen and press the or key to enter the maintenance screen 2 Press the EN...

Страница 36: ...ower Off Setting You can set ON OFF of the auto power off function When this function is ON and no key operations are performed for the set period the instrument is powered OFF automatically 1 Press t...

Страница 37: ...ENTER key to enter the auto power off change screen 5 Press the or key to change ON or OFF and press the ENTER key 6 P ress the or key to select a digit and press the or key to change the value and th...

Страница 38: ...the SET key on the measurement screen and press the or key to enter the maintenance screen 2 Press the ENTER key to enter the maintenance item selecting screen 3 Press the or key to enter the date se...

Страница 39: ...or key to change the value for hour and minute setting and press the ENTER key to return to the date setting screen Memory Data Clearing You can delete the memory data of the instrument This operatio...

Страница 40: ...n 3 Press the or key to enter the memory data clear screen 4 Press the ENTER key to enter the memory data clear Yes No screen 5 Press the or key to select Yes and press ENTER key to delete the memory...

Страница 41: ...onductivity and salinity to initialize them Note that this operation is irreversible 1 Press the SET key on the measurement screen and press the or key to enter the maintenance screen 2 Press the ENTE...

Страница 42: ...surement item to be deleted 5 Press the ENTER key to enter the calibration data deleting Yes No screen 6 Press the or key to select Yes and press ENTER key to delete the calibration data When the dele...

Страница 43: ...on the measurement screen and press the or key to enter the maintenance screen 2 Press the ENTER key to enter the maintenance item selecting screen 3 Press the or key to enter the number of mem ory da...

Страница 44: ...r of an electrode 1 Press the SET key on the measurement screen and press the or key to enter the maintenance screen 2 Press the ENTER key to enter the maintenance item selecting screen 3 Press the or...

Страница 45: ...s the ENTER key to return to the temperature calibra tion screen Setting Initialization The settings are initialized Refer to 5 2 Default Settings P 64 for default settings 1 Press the SET key on the...

Страница 46: ...ng set tings screen 4 Press the ENTER key to enter the initializing set tings Yes No screen 5 Press the or key to select Yes and press ENTER key to initialize the settings The initializing is complete...

Страница 47: ...a or operating acci dentally to change settings delete memory data etc 1 Press the SET key on the measurement screen and press the or key to enter the maintenance screen 2 Press the ENTER key to enter...

Страница 48: ...a digit and press the or key to change the value and then press the ENTER key and press the ENTER key to return to the password change screen Setting range 0000 to 9999 If this setting is ON password...

Страница 49: ...r the current electrode 1 Prepare the potassium chloride standard solution Refer to JIS K 0400 for the preparative method 2 Wash the electrode with pure water deionized and wipe it off by filter paper...

Страница 50: ...ity Calibration You can perform 1 point calibration using a salinity stan dard solution 1 Prepare the electrode Wash the electrode with pure water deionized and wipe it off by filter paper or tissue p...

Страница 51: ...e indication value and press the CAL key The HOLD indicator blinks until the reading stabilizes When the reading stabilizes the HOLD indicator lights up and the reading is held 7 After the calibration...

Страница 52: ...nnected correctly Refer to 3 1 4 Connecting and Setting the Printer P 13 2 Press the DATA key during calibration HOLD or calibration error The currently displayed data is printed out Printing examples...

Страница 53: ...is displayed in the instantaneous measurement and the HOLD indicator blinks Then when the value is stable the HOLD indicator lights up and the value is held To cancel the HOLD state or to stop the sta...

Страница 54: ...Measurement 44 HORIBA 3 4 2 Measurement Items Changing When the MODE key is pressed measurement item can be changed COND measurement MODE key Resistivity measurement MODE key Salinity measurement MODE...

Страница 55: ...Auto LOG is displayed on the screen 2 Press the ENTER key Auto LOGGING is displayed on the screen and the auto data memory function starts 3 To stop the auto data memory press the ENTER key Do not pow...

Страница 56: ...ed in the calibration mode 1 Check that the printer settings and connection are correctly Refer to 3 1 4 Connecting and Setting the Printer P 13 2 Press the key in the measurement mode or HOLD state T...

Страница 57: ...mode MTC At Auto mode ATC Sample ID Instrument model Serial number Calibration coefficient Temperature coefficient alinity measurement mode TDS measurement mode HOLD condition At HOLD AUTO Instant va...

Страница 58: ...easurement 48 HORIBA Resistivity measurement mode HOLD condition At HOLD AUTO Instant value INST Temperature compensation setting At Manual mode MTC At Auto mode ATC Sample ID Instrument model Serial...

Страница 59: ...be stored into the instrument memory Refer to 3 4 3 Auto Data Memory P 45 for automatic data memory 1 Press the DATA key to enter the data operation screen 2 Press the ENTER key to enter the data memo...

Страница 60: ...ata can be displayed on the screen 1 Press the DATA key to enter the data operation mode 2 Press the or key to enter the memory data dis play screen 3 The latest data is displayed 4 Press the or key t...

Страница 61: ...asurement data is printed out COND measurement mode Memory number HOLD condition At HOLD AUTO Instant value INST Temperature compensation setting At Manual mode MTC At Auto mode ATC Sample ID Instrume...

Страница 62: ...erature compensation setting At Manual mode MTC At Auto mode ATC Sample ID Instrument model Serial number alinity measurement mode TDS measurement mode Memory number HOLD condition At HOLD AUTO Instan...

Страница 63: ...to take appropriate countermeasures 4 1 Conductivity Electrode Maintenance Refer to the electrode operation manuals for the mainte nance operations of each electrode Long term storage When an electro...

Страница 64: ...hand corner of the screen 4 2 1 Error Message Chart ERROR No Message Definition 0001 Memory ERROR Data cannot be read from or written to the internal memory 0003 Unstable reading ERROR The electric po...

Страница 65: ...HORIBA sales representative ERROR No 0003 Unstable reading ERROR Definition The electric potential does not stabilize within three minutes Cause Countermeasure This is caused by the effect of the samp...

Страница 66: ...nter connection and con nect the instrument and printer again The printer is defective Replace the printer If the same error occurs again after the countermeasure is performed contact HORIBA sales rep...

Страница 67: ...t the end of the useful life Replace the electrode Improper standard solution Prepare new standard solution ERROR No 000E Key operation ERROR Definition Key operation is invalid Cause Countermeasure L...

Страница 68: ...electrode Cause Countermeasure There are air bub bles on the elec trode Shake the electrode to remove the air bubbles Plating has sepa rated Replace the electrode When there is a problem with the ins...

Страница 69: ...es representative The electrode con nector is not attached correctly Turn the power OFF then turn it back ON again The electrode is defective Replace the electrode The pH meter is defective Contact HO...

Страница 70: ...onnect the electrode If the displayed measurement value is near 0 the instrument is normal The temperature display blinks The temperature display is fixed at 25 C The temperature measurement value is...

Страница 71: ...he following points Is the printer turned ON Is an error occurred in printer Is the printing paper run out or clogged When the test print is made according to the manual is it done correctly The setti...

Страница 72: ...Thermistor method Measuring range 0 0 C to 100 0 C Display resolution 0 1 C Repeatability 0 1 C 1 digit Conductivity Measuring principle 2 AC bipolar method Measuring range Cell constant 100 m 1 0 00...

Страница 73: ...9 k m Cell constant 10 m 1 0 0 m to 1 999 M m Cell constant 1000 m 1 0 000 m to 19 99 k m Display resolution 0 05 of full scale Repeatability 0 5 1 digit of full scale Salinity Measuring principle Co...

Страница 74: ...ngs Temperature compensation Automatic temperature compensation ATC Manual temperature compensation value 25 C Auto power off OFF Sample ID 0000 Calibration interval OFF Password OFF Auto data memory...

Страница 75: ...014031951 AC adapter Cable EU 230 V 3014031952 Plain paper printer Printer USA 120 V 3014030146 Printer cable sold separately Printer EU 230 V 3014030147 Printer cable 3014030148 1 5 m Roll paper 3014...

Страница 76: ......

Страница 77: ...For any question regarding this product please contact your local agency or inquire from the Customer Registration website http www horiba com register 1st edition October 2011 CODE GZ0000260899...

Страница 78: ......

Отзывы: