![hopf 6842 GPS Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/hopf/6842-gps/6842-gps_technical-manual_2161862066.webp)
COM0 / COM1 S
ERIAL
I
NTERFACES
66 / 98
6842 GPS Slim Line System - V09.01
hopf
Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
5.3.8 IBM Sysplex Timer Model 1+2
This protocol is used for the synchronization of an IBM 9037 Sysplex Timer. The IBM
Sysplex Timer expects the time at its input every second.
While starting the Sysplex Timer the ASCII-sign
"C"
is sent to the connected radio controlled
clock. The listed protocol in the table is automatically given out every second by that.
5.3.8.1 Specified Settings
Automatic:
The following parameters are activated
after a reset
:
automatically
•
9600 baud
•
8 data bit
•
odd parity
•
1 stop bit
•
sending on request without forerun
and without control characters
Required:
no
Blocked:
no
The setting UTC or local time is optional.
The above parameters can be changed manually after activating. But after
a reset or a system reboot the parameters will be overwritten with the above
parameters again.
5.3.8.2 Structure
Character No.
Meaning
Hex-Value
1
SOH (start of header)
$02
2
hundreds current day of the year
$30-33
3 tens
current
year
$30-39
4 unit
current
year
$30-39
5 ":"
colon
$3A
6 tens
hour
$30-32
7 unit
hour
$30-39
8 ":"
colon
$3A
9 tens
minute
$30-35
10 unit
minute
$30-39
11 ":"
colon
$3A
12 tens
second
$30-35
13 unit
second
$30-39
14 Quality
Identifier
$20, 41, 42, 43, 58
15
CR (carriage return)
$0D
16
LF (line feed)
$0A