COM0 / COM1 S
ERIAL
I
NTERFACES
6842 GPS Slim Line System - V09.01
59 / 98
hopf
Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
5.3.4.3 Status
The characters 28-31 in the data string SINEC H1 tell the synchronisation status of the clock.
The characters mean the following:
character no. 28 = "#"
no radio synchronisation after reset, time invalid
space
radio synchronisation after reset, clock in crystal operation
character no. 29 = "*"
time from internal crystal in the clock
space
time by radio reception
character no. 30 = "S"
daylight saving time
space
standard time
character no. 31 = "!"
announcement of a W/S or S/W change over
space
no announcement
5.3.4.4 Example
(STX)D:18.07.02;T:4;U:12.34.56; _ _ _ _ (ETX)
( _ ) = Space
•
It is Thursday 18.07.02 - 12:34:56 o'clock
•
radio operation
•
standard time
•
no announcement ST/WT change over