SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
MCS--4200/7200 Multi--Channel SATCOM System
23--20--35
15 Jul 2006
Honeywell International Inc. Do not copy without express permission of Honeywell.
Page 6--40
(5) SATCOM SELF--TEST (PAST) Page
(a) General
1
The purpose of this page is to initiate a PAST, to enable/disable a voice
loopback on a selected (physical) channel, to enable/disable a test of the
cockpit voice call light for a selected (logical) channel, and activation of the
cockpit voice go-ahead chime test. See Figure 6-7 for example pages.
(b) Data Fields
1
Line 1
a
This line displays the title of the page, SAT--N, beginning in column 10,
where N represents 1 or 2 to indicate a single SDU (N = 1), SDU No. 1
(N = 1), or SDU No. 2 (N = 2) as determined by the settings of
configuration pins TP12E and TP12F.
b
If there are current failures to report after the execution of a PAST,
columns 20 thru 24 display p/t in small font, where p represents the
current displayed page, and t represents the total number of pages
needed to show the current failures. The display of the slash is always
in column 22, with p right-justified to the slash and t left-justified to the
slash.
2
Line 3
a
This line displays headers ATA beginning in column 1 and CLASS
beginning in column 20 if there are current failures to report after
execution of a PAST. This line is blank if there are no failures to report.
b
In addition to the above, for CFDS type none, the header ATA is not
displayed (CLASS is still displayed as specified).
3
Line 5
a
This line displays the message TEST IN PROGRESS 60S beginning in
column 3 within one second of a PAST being initiated on the SAT--N
(i.e., SATCOM MAINTENANCE) page, and then throughout the duration
of PAST. If there are no current failures to report at the conclusion of the
PAST (including the POST/PAST results delay period), the message
TEST OK is displayed. If there are current failures to report at the
conclusion of the PAST (including the POST/PAST results delay period),
refer to paragraph 4 for line requirements.