![Honeywell StratosH MS2320 Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/honeywell/stratosh-ms2320/stratosh-ms2320_installation-and-user-manual_152610063.webp)
S
CANNER AND
C
ABLE
T
ERMINATIONS
S
CANNER
P
INOUT
C
ONNECTIONS
Figure 65. Scale Data (Dual Cable Applications) and Scale Display Connector Layout
Scale RS232 to Host
Scale Data, Dual Cable Applications
Scale to Display
Pin
Function
**
Pin
Function
**
1 Ground
1 SIG1
2
Scale RS232 TX Out
2
SIG2
3
Scale RS232 RX In
3
SIG3
4
Scale RS232 RTS Out
4
SIG4
5
Scale RS232 CTS In
5
SIG5
6
No Connect
6 SIG6
7
No Connect
7 SIG7
8
No Connect
8 SIG8
9
Reserved
9
No Connect
10 Shield
10
No Connect
** All signals referenced from the StratosH scanner.
Specifications are subject to change without notice.