![Honeywell StratosH MS2320 Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/honeywell/stratosh-ms2320/stratosh-ms2320_installation-and-user-manual_152610031.webp)
I
NSTALLATION
C
ABLE
I
NSTALLATION
(S
ECONDARY
H
ONEYWELL
S
CANNER
)
The following steps describe how to properly install the cables between a secondary
Honeywell
scanner
and the Stratos
H
. The
Stratos
H
and the secondary scanner
must
then be configured to communicate properly. Cable installation alone
does not
guarantee
that the Stratos
H
will communicate properly with the host system and secondary scanner.
Contact a customer service representative
before
connecting another manufacturer’s scanner to the Stratos
H
as a secondary
scanner.
Configuration bar codes are located in the MS2
x
20 Stratos Series Scanner/Diva Scale Configuration Addendum
(
PN
00-02272
x
) under
Scanner Configuration Bar Codes: Auxiliary Port, Quick Start for a Secondary Honeywell Scanner
.
1. Refer to pages 16 - 23 for the type of interface
(RS232, RS485, etc.)
required for the application. Follow the cable installation
steps under the appropriate interface before continuing. Once the communication and power cables have been installed follow
step 2 below for the secondary scanner installation.
2. Connect
the
straight
end of the RS232 PowerLink AUX cable (
PN
57-57099
x
-3) to the RS232 into the socket of the
secondary
scanner (
see figure on page 26
).
3. Connect
the
angled
end of the RS232 AUX cable (
PN
57-57099
x
-3) into the 10-pin socket labeled,
Aux RS232 In
,
on the bottom
of the Stratos
H.
Important: The StratosH series’ aux port requires the signals; transmit, receive, RTS & CTS from the secondary scanner.
The Stratos
H
’s auxiliary port will support 5VDC devices with a 150mA maximum current. If the auxiliary device exceeds this
specification or requires a different voltage, an external power supply will be required to power the auxiliary device.
The following Honeywell scanners can receive power from Stratos
H
: the MS9520, MS9540, and the MS5145.
4.
This step is required for secondary devices that require >5VDC and/or 150mA current to operate.
Skip to step 5 if the
secondary device requires
≤
150mA 5VDC.
Plug the power supply into the
secondary
scanner’s PowerLink cable (
PN
57-57099
x
-3) and connect AC power to the secondary
scanner.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet should
be located near the equipment and be easily accessible.
5. Configure the Stratos
H
and the secondary scanner. The auxiliary input port’s data format must match the main output format of
the secondary scanner.
Refer to the MS2
x
20 Stratos Series Scanner/Diva Scale Configuration Addendum (
PN
00-02272
x
) under
Scanner
Configuration Bar Codes: Auxiliary Port, Quick Start for a Secondary Honeywell Scanner
.