I
NSTALLATION
C
ABLE
I
NSTALLATION
(I
NTERFACE
S
PECIFIC
)
OCIA
The following steps describe how to properly install the cables for an OCIA Stratos
H
application. The scanner/scale
must
then be
configured to match the host’s OCIA parameters. Cable installation alone
does not
guarantee that the Stratos
H
will communicate
properly with the host system.
Configuration bar codes are located in the MetroSelect Configuration Guide
(
PN
00-02407
x
) and the MS2
x
20 Stratos Series
Scanner/Diva Scale Configuration Addendum (
PN
00-02272
x
).
1. Turn off the host system.
2. Plug the 10-pin RJ45 end of the OCIA interface cable (
PN
57-57015
x
-N-3) into the 10-pin socket labeled,
Scanner OCIA to Host
on the bottom of the Stratos
H
. Refer to figure on page 24.
3. Connect the other end of the OCIA Interface cable (
PN
57-57015
x
-N-3) to the appropriate communication port on the host device.
Before continuing verify that the OCIA cable pinouts match the host system’s and is connected to the appropriate interface
socket on the scanner. An incorrect cable connection can cause communication problems or potential damage to the
scanner and/or terminal.
Manufacturers Note:
Plugging the scanner into the serial port of the host device does not guarantee that scanned
information will appear at the host device. A software driver and correct configuration settings are also required for proper
communication to occur.
Steps 4 and 5 are for
dual cable
interfaces where the scale and the scanner connect to the host with their own separate
communication cables. Skip to step 6 for a
single cable
interface where the scale and scanner connect to the host with a single cable.
4. Plug the dual interface cable (
PN
57-57000
x
-N-3) into the 10-pin socket labeled,
Scale RS232 to Host
, on the bottom of the
Stratos
H
.
5. Connect the other end of the dual interface cable (
PN
57-57000
x
-N-3) to the appropriate communication port on the host’s scale
device.
6. Plug
the
optional
remote display cable** into the 10-pin socket labeled,
Scale to Display
, on the bottom of the Stratos
H
.
** See page 3 for information on optional display types and part numbers
.
7. Plug the external power supply (
PN
46-46
xxx
*
) into the 3-pin Molex socket labeled,
DC Power
In
, on the bottom of
the Stratos
H
.
xxx
*
Specifies international connection. See
Optional Accessories
in the
Introduction
section of this guide for a complete listing.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet should
be located near the equipment and be easily accessible.
Honeywell recommends using a switched AC outlet. The switch should be located on the operator’s side of the checkout
counter in close proximity to the Stratos
H
to facilitate calibration and service of the unit.
23