Parameter
Default
Function
Tray Icon
On
Determines if the Summit icon is displayed in the System tray.
Options are: On, Off
Hide Password
On
When On, the Summit Config Utility masks passwords (characters on the
screen are displayed as an *) as they are typed and when they are viewed.
When Off, password characters are not masked.
Options are: On, Off.
Admin Password
SUMMIT
(or Blank)
A string of up to 64 alphanumeric characters that must be entered when the
Admin Login button is tapped. If Hide Password is On, the password is
masked when typed in the Admin Password Entry dialog box. The password
is case sensitive. This value is masked when the Admin is logged out.
Options are: none.
Auth Timeout
8 seconds
Specifies the number of seconds the Summit software waits for an EAP
authentication request to succeed or fail.
If the authentication credentials are stored in the active profile and the
authentication times out, the association fails. No error message or
prompting for corrected credentials is displayed.
If the authentication credentials are not stored in the active profile and the
authentication times out, the user is again prompted to enter the credentials.
Options are: An integer from 3 to 60.
Certs Path
System
A valid directory path, of up to 64 characters, where WPA Certificate
Authority and User Certificates are stored on the mobile device when not
using the Windows certificates store. Make sure the Windows folder path
currently exists before assigning the path in this parameter. See
for instructions on obtaining CA and User Certificates. This value is masked
when the Admin is logged out.
Options are: none.
For example, when the valid certificate is stored as My
Computer/System/MYCERTIFICATE.CER, enter System in the Certs Path
text box as the Windows folder path.
Ping Payload
32 bytes
Maximum amount of data to be transmitted on a ping.
Options are: 32 bytes, 64, 128, 256, 512, or 1024 bytes.
Ping Timeout ms
5000
The amount of time, in milliseconds, that a device will be continuously
pinged. The Stop Ping button can be tapped to end the ping process ahead of
the ping timeout.
Options are: Any number between 0 and 30000 ms.
Ping Delay ms
1000
The amount of time, in milliseconds, between each ping after a Start Ping
button tap.
Options are: Any number between 0 and 30000 ms.
Note:
Tap the Commit button to save changes. If this panel is closed before tapping the Commit button, changes are not
saved!
8-18
Содержание MX7 Tecton
Страница 1: ...MX7 Tecton Hand Held Computer Microsoft Windows Embedded CE 6 Operating System Reference Guide ...
Страница 14: ...xiv ...
Страница 24: ...1 10 ...
Страница 38: ...3 4 ...
Страница 166: ...Hat Encoding Hat Encoded Characters Hex 00 through AD 4 128 ...
Страница 167: ...Hat Encoded Characters Hex AE through FF 4 129 ...
Страница 176: ...4 138 ...
Страница 177: ...4 139 ...
Страница 202: ...Enter user name password and domain to be used when logging into network resources 4 164 ...
Страница 209: ...4 171 ...
Страница 240: ...5 22 ...
Страница 276: ...7 30 ...
Страница 320: ...8 44 ...
Страница 325: ...Click the Request a certificate link Click on the advanced certificate request link 8 49 ...
Страница 326: ...Click on the Create and submit a request to this CA link 8 50 ...
Страница 334: ...8 58 ...
Страница 358: ...9 24 ...
Страница 362: ...10 4 ...
Страница 365: ...11 3 ...
Страница 366: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com E EQ MX7CERG Rev E 10 12 ...