HI-SPEC unit_HON.doc
07/2011
4 of 12
HEAD 1
DIAG
BR1
X8
BR2
BR3
1 2
HEAD 1
HEAD 2
DIAG
DISPLAY
BR1
X8
BR2
F2
CUTOFF
X1
BR3
SCI
ITAG
BR3
BR
1
1 2
X1
1
1
2
2
3
X2
Br1
Br1
Br1
Br2
Br2
Br2
Choose number of the detector modules
The number of detector modules is chosen with the jumper BR1. The following table shows, whether the jumper must be put or not:
X = pin pair bridge
O = pin pair open
The standard settings have a grey background.
Choose number of the detector
modules
Bridge
Pin No.
BR1,
1+2
1 detector module
X
2 detector module
O
Setting the ventilator voltage
Jumper BR3 on the base board and Jumper BR1 on the additional board allows the setup of the ventilator voltage. The following table shows whether
the jumpers are set or not:
X = pin pair bridge
O = pin pair open
The standard settings have a grey background.
Setting the ventilator voltage
base-
board
additional
board
Jumper
Pin No.
BR 3
1 + 2
BR 1
1 + 2
BR 2
1 + 2
6,5 V
O O X
6,9 V
O
X
O
9 V
O O O