background image

152 

HH490 User Guide 

Example: 

Edge Sharpen at 0E: 

Edge Sharpen at 24E:

 

 

 

 

 

 

 

F - File Format 

 

Indicates the desired format for the image. 

 

0F 

1F 

2F 

3F 

4F 
 

5F 

6F 

8F 

15F

 

KIM format 

TIFF binary 

TIFF binary group 4, compressed 

TIFF grayscale 

Uncompressed binary (upper left to lower right, 1 pixel/bit, 0 padded 
end of line) 

Uncompressed grayscale (upper left to lower right, bitmap format) 

JPEG image 

(default) 

BMP format (lower right to upper left, uncompressed) 

BMP Uncompressed raw image

 

 

H - Histogram Stretch 

 

Increases the contrast of the transmitted image. Not available with some image 
formats. 

 

0H 

1H

 

No stretch 

(default) 

Histogram stretch 

Содержание HH490

Страница 1: ...HH490 Area Imaging Scanner User Guide ...

Страница 2: ...o achieve intended results This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of HII Copyright 2018 2020 Honeywell International Inc All rights reserved Web Address www honeywellaidc com Trademarks Microsoft Windows and the ...

Страница 3: ...1 Connect with RS232 Serial Port 2 Reading Techniques 3 Menu Barcode Security Settings 3 Set Custom Defaults 3 Reset the Custom Defaults 4 CHAPTER 2 PROGRAM THE INTERFACE 5 Introduction 5 Program the Interface Plug and Play 5 RS232 Serial Port 5 USB IBM SurePos 6 USB PC or Macintosh Keyboard 6 USB HID 7 USB Serial 7 CTS RTS Emulation 7 ACK NAK Mode 8 Remote MasterMind for USB 8 Keyboard Country La...

Страница 4: ...Character 23 Trigger Click 24 Good Read and Error Indicators 24 Beeper Good Read 24 Beeper Volume Good Read 24 Beeper Pitch Good Read 25 Beeper Pitch Error 25 Beeper Duration Good Read 25 LED Good Read 26 Number of Beeps Good Read 26 Number of Beeps Error 26 Good Read Delay 27 User Specified Good Read Delay 27 Trigger Modes 27 Manual Trigger 27 Serial Trigger 28 Presentation Mode 28 Presentation L...

Страница 5: ...37 User Specified Aimer Delay 37 Aimer Mode 37 Centering 38 Single Code Centering 38 Custom Centering 38 Preferred Symbology 40 High Priority Symbology 40 Low Priority Symbology 41 Preferred Symbology Time out 41 Preferred Symbology Default 41 Output Sequence Overview 42 Output Sequence Editor 42 To Add an Output Sequence 42 Output Sequence Editor Commands 43 Enter Output Sequence 46 Partial Seque...

Страница 6: ... Delay 58 CHAPTER 5 DATA FORMAT 59 Data Format Editor Introduction 59 Show Data Format 60 Add a Data Format 60 Other Programming Selections 61 Terminal ID Table 62 Data Format Editor Commands 62 Send Commands 63 Move Commands 68 Search Commands 70 Miscellaneous Commands 73 Data Formatter 77 Data Format Non Match Error Tone 78 Primary Alternate Data Formats 79 Single Scan Data Format Change 79 CHAP...

Страница 7: ...of 5 Message Length 90 Code 93 91 Code 93 On Off 91 Code 93 Message Length 91 Code 93 Append 91 Code 93 Code Page 92 Straight 2 of 5 Industrial three bar start stop 92 Straight 2 of 5 Industrial On Off 92 Straight 2 of 5 Industrial Message Length 93 Straight 2 of 5 IATA two bar start stop 93 Straight 2 of 5 IATA On Off 93 Straight 2 of 5 IATA Redundancy 93 Straight 2 of 5 IATA Message Length 94 Ma...

Страница 8: ... A Number System 101 UPC A Addenda 102 UPC A Addenda Required 102 Addenda Timeout 102 UPC A Addenda Separator 103 UPC A EAN 13 with Extended Coupon Code 103 Addenda Timeout 104 Coupon GS1 DataBar Output 104 UPC E0 104 UPC E0 On Off 105 UPC E0 Expand 105 UPC E0 Addenda Required 105 Addenda Timeout 106 UPC E0 Addenda Separator 106 UPC E0 Check Digit 106 UPC E0 Leading Zero 107 UPC E0 Addenda 107 UPC...

Страница 9: ...anslate 115 EAN JAN 8 115 EAN JAN 8 On Off 115 EAN JAN 8 Check Digit 116 EAN JAN 8 Addenda 116 EAN JAN 8 Addenda Required 116 Addenda Timeout 117 EAN JAN 8 Addenda Separator 117 MSI 117 MSI On Off 118 MSI Check Character 118 MSI Message Length 119 GS1 DataBar Omnidirectional 119 GS1 DataBar Omnidirectional On Off 119 GS1 DataBar Limited 120 GS1 DataBar Limited On Off 120 GS1 DataBar Expanded 120 G...

Страница 10: ... Code Append 128 QR Code Page 129 DotCode 129 DotCode On Off 130 Poor Quality DotCodes 130 DotCode Message Length 130 Digimarc Barcode 131 Digimarc Decoder Attempts 131 Digimarc Barcode 131 Data Matrix 132 Data Matrix On Off 132 Direct Part Marking Decoding 132 Data Matrix Message Length 133 Data Matrix Code Page 133 MaxiCode 134 MaxiCode On Off 134 MaxiCode Message Length 134 Aztec Code 134 Aztec...

Страница 11: ... IMGSNP 146 Image Snap IMGSNP 146 IMGSNP Modifiers 146 Step 2 Ship a Picture Using IMGSHP 150 Image Ship IMGSHP 150 IMGSHP Modifiers 150 CHAPTER 8 UTILITIES 159 Add a Test Code I D Prefix to All Symbologies 159 Show Software Revision 159 Test Menu 159 Application Plug Ins 160 EZConfig for Scanning Introduction 160 Configure with EZConfig for Scanning 161 Reset the Factory Defaults 161 CHAPTER 9 SE...

Страница 12: ...t 195 USB 196 CHAPTER 12 MAINTENANCE AND TROUBLESHOOTING 197 Repairs 197 Maintenance 197 Clean the Scanner 197 About Disinfectant ready Models 198 Inspect Cords and Connectors 198 Replace Cables in Corded Scanners 198 Replace an Interface Cable 199 Troubleshoot a Corded Scanner 200 APPENDIX A REFERENCE CHARTS 201 Symbology Charts 201 Linear Symbologies 201 2D Symbologies 202 Postal Symbologies 203...

Страница 13: ...llaidc com locations Product Service and Repair Honeywell International Inc provides service for all of its products through service centers throughout the world To obtain warranty or non warranty service return your product to Honeywell postage paid with a copy of the dated purchase record To learn more go to www honeywellaidc com and select Service Repair at the bottom of the page Limited Warran...

Страница 14: ...xiv HH490 User Guide ...

Страница 15: ...ished by scanning the barcodes in this guide An asterisk next to an option indicates the default setting Unpack Your Device After you open the shipping carton containing the product take the following steps Check for damage during shipment Report damage immediately to the carrier who delivered the carton Make sure the items in the carton match your order Save the shipping container for later stora...

Страница 16: ...minal computer 2 Connect the appropriate interface cable to the scanner Note For the scanner to work properly you must have the correct cable for your type of terminal computer HH490 Scanner RS232 Serial Port Connection Note The power supply must be ordered separately if needed ...

Страница 17: ...s To do so scan the Set Custom Defaults barcode below before scanning the menu commands for your custom defaults If a menu command requires scanning numeric codes from the Programming Chart then a Save code that entire sequence will be saved to your custom defaults When you have entered all the commands you want to save for your custom defaults scan the Save Custom Defaults barcode Set Custom Defa...

Страница 18: ...de below This is the recommended default barcode for most users It resets the scanner to the custom default settings If there are no custom defaults it will reset the scanner to the factory default settings Any settings that have not been specified through the custom defaults will be defaulted to the factory default settings Activate Custom Defaults ...

Страница 19: ... of the codes power cycle the host terminal to have the interface in effect RS232 Serial Port The RS232 Interface barcode is used when connecting to the serial port of a PC or terminal The following RS232 Interface barcode also programs a carriage return CR and a line feed LF suffix baud rate and data format as indicated below It also changes the trigger mode to manual Option Setting Baud Rate 115...

Страница 20: ... Handheld Scanner Interface USB IBM SurePos USB Tabletop Scanner Interface Each barcode above also programs the following suffixes for each symbology Symbology Suffix Symbology Suffix EAN 8 0C Code 39 00 0A 0B EAN 13 16 Interleaved 2 of 5 00 0D 0B UPC A 0D Code 128 00 18 0B UPC E 0A Code 39 00 0A 0B USB PC or Macintosh Keyboard Scan one of the following codes to program the scanner for USB PC Keyb...

Страница 21: ...e scanner as a USB CDC class device and automatically use a class driver After the driver is downloaded scan the following code to program the scanner to emulate a regular RS232 based COM Port USB Serial No extra configuration e g baud rate is necessary Note If you scan the USB Serial barcode either with an older Honeywell serial driver or no driver installed you may no longer be able to scan barc...

Страница 22: ...can ReM Off Default ReM On ReM Off ReM On Keyboard Country Layout If your interface is USB Keyboard or Keyboard Wedge your keyboard layout default is a US keyboard To change this layout scan the appropriate Keyboard Country barcode below By default national character replacements are used for the following characters Refer to the ISO 2022 ISO 646 Character Replacements on page A 207 to view the ch...

Страница 23: ...HH490 User Guide 9 Keyboard Countries Continued Belarus Belgium Bosnia Brazil Brazil MS Bulgaria Cyrillic Bulgaria Latin Canada French legacy Canada French Canada Multilingual Croatia Czech ...

Страница 24: ...10 HH490 User Guide Keyboard Countries Continued Czech Programmers Czech QWERTY Czech QWERTZ Denmark Dutch Netherlands Estonia Faroese Finland France Gaelic Germany Greek ...

Страница 25: ...HH490 User Guide 11 Keyboard Countries Continued Greek 220 Latin Greek 220 Greek 319 Latin Greek 319 Greek Latin Greek MS Greek Polytonic Hebrew Hungarian 101 key Hungary Iceland Irish ...

Страница 26: ...12 HH490 User Guide Keyboard Countries Continued Italian 142 Italy Japan ASCII Kazakh Kyrgyz Cyrillic Latin America Latvia Latvia QWERTY Lithuania Lithuania IBM Macedonia Malta ...

Страница 27: ...HH490 User Guide 13 Keyboard Countries Continued Mongolian Cyrillic Norway Poland Polish 214 Polish Programmers Portugal Romania Russia Russian MS Russian Typewriter SCS Serbia Cyrillic ...

Страница 28: ...14 HH490 User Guide Keyboard Countries Continued Serbia Latin Slovakia Slovakia QWERTY Slovakia QWERTZ Slovenia Spain Spanish variation Sweden Switzerland French Switzerland German Tatar Turkey F ...

Страница 29: ...arcode contains special characters from the extended ASCII chart for example an e with an accent grave è you will use ALT Mode See Extended ASCII Characters on page207 Note Scan the ALT mode barcode after scanning the appropriate Keyboard Country code If your keystrokes require the ALT key and 3 or 4 characters scan the 3 Characters or 4 Characters barcode The data is then output with the special ...

Страница 30: ...ed when you normally have the Shift Lock key on not common to U S keyboards Shift Lock Keyboard Conversion Alphabetic keyboard characters can be forced to be all upper case or all lowercase So if you have the following barcode abc569GK you can make the output ABC569GK by scanning Convert All Characters to Upper Case or to abc569gk by scanning Convert All Characters to Lower Case These settings ove...

Страница 31: ...ff Keyboard Modifiers This modifies special keyboard features such as CTRL ASCII codes and Turbo Mode Control X Control ASCII Mode On The scanner sends key combinations for ASCII control characters for values 00 1F Windows is the preferred mode All keyboard country codes are supported DOS mode is a legacy mode and it does not support all keyboard country codes New users should use the Windows mode...

Страница 32: ... X Mode On with Windows Mode Prefix Suffix Supports ALT 3 Digit HEX Mode Turbo Mode The scanner sends characters to a terminal faster If the terminal drops characters do not use Turbo Mode Default Off Turbo Mode On Turbo Mode Off Numeric Keypad Mode Sends numeric characters as if entered from a numeric keypad Default Off Numeric Keypad Mode On Numeric Keypad Mode Off ...

Страница 33: ...ault 115 200 300 600 1200 2400 4800 9600 19200 38400 57 600 115 200 RS232 Word Length Data Bits Stop Bits and Parity Data Bits sets the word length at 7 or 8 bits of data per character If an application requires only ASCII Hex characters 0 through 7F decimal text digits and punctuation select 7 data bits For applications that require use of the full ASCII set select 8 data bits per character Defau...

Страница 34: ...y Mark RS232 Receiver Time Out The unit stays awake to receive data until the RS232 Receiver Time Out expires A manual or serial trigger resets the time out When an RS232 receiver is sleeping a character may be sent to wake up the receiver and reset the time out A transaction on the CTS line will also wake up the receiver The receiver takes 300 milliseconds to completely come up Change the RS232 r...

Страница 35: ...rol with Timeout The scanner asserts RTS when it has data to send and waits for a delay see RS232 Timeout on page 37 for CTS to be asserted by the host If the delay time expires and CTS is not asserted the device transmit buffer is cleared and scanning may resume Default RTS CTS Off Flow Control No Timeout Two Direction Flow Control Flow Control with Timeout RTS CTS Off RS232 Timeout When using Fl...

Страница 36: ...t left off when XOFF was sent Default XON XOFF Off XON XOFF On XON XOFF Off ACK NAK After transmitting data the scanner waits for an ACK character hex 06 or a NAK character hex 15 response from the host If ACK is received the communications cycle is completed and the scanner looks for more barcodes If NAK is received the last set of barcode data is retransmitted and the scanner waits for ACK NAK a...

Страница 37: ...an the Off barcode s if you don t want a power up beep Default Power Up Beeper On Scanner Power Up Beeper Off Scanner Power Up Beeper On Scanner Beep on BEL Character You may wish to force the scanner to beep upon a command sent from the host If you scan the Beep on BEL On barcode below the scanner will beep every time a BEL character is received from the host Default Beep on BEL Off Beep on BEL O...

Страница 38: ... Click Off Trigger Click Off Trigger Click On Good Read and Error Indicators Beeper Good Read The beeper may be programmed On or Off in response to a good read Turning this option off only turns off the beeper response to a good read indication All error and menu beeps are still audible Default Beeper Good Read On Beeper Good Read Off Beeper Good Read On Beeper Volume Good Read The beeper volume c...

Страница 39: ...Medium 2700 Hz High 4200 Hz Beeper Pitch Error The beeper pitch codes modify the pitch frequency of the sound the scanner emits when there is a bad read or error Default Razz Razz 250 Hz Medium 3250 Hz High 4200 Hz Beeper Duration Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read Default Normal Normal Beep Short Beep ...

Страница 40: ...are in sync with one another To change the number of beeps scan the barcode below and then scan a digit 1 9 barcode from the Programming Chart beginning on page 211 then Save Default 1 Number of Good Read Beeps LED Flashes Number of Beeps Error The number of beeps and LED flashes emitted by the scanner for a bad read or error can be programmed from 1 9 For example if you program this option to hav...

Страница 41: ... Programming Chart beginning on page 211 then Save User Specified Good Read Delay Trigger Modes Manual Trigger When in manual trigger mode the scanner scans until a barcode is read or until the trigger is released Two modes are available Normal and Enhanced Normal mode offers good scan speed and the longest working ranges depth of field Enhanced mode will give you the highest possible scan speed b...

Страница 42: ...he scanner s trigger when using serial commands to trigger the scanner Once the scanner has timed out you can activate the scanner either by pressing the trigger or using a serial trigger command After scanning the Read Time Out barcode set the time out duration from 0 300 000 milliseconds by scanning digits from the Programming Chart beginning on page 211 then Save Default 30 000 ms Read Time Out...

Страница 43: ... the desired codes are read Note To adjust centering when the scanner is hand held see Centering page 48 If a barcode is not touched by a predefined window it will not be decoded or output by the scanner If Presentation Centering is turned on by scanning Presentation Centering On the scanner only reads codes that pass through the centering window you specify using the Top of Presentation Centering...

Страница 44: ...p bottom left or right of the centering window Then scan the percent you want to shift the centering window from the Programming Chart beginning on page 211 then Save Default Presentation Centering 40 for Top and Left 60 for Bottom and Right Presentation Centering On Presentation Centering Off Top of Presentation Centering Window Bottom of Presentation Centering Window 0 Barcode 1 10 Barcode 2 20 ...

Страница 45: ...d making it less aggressive when reading good quality barcodes This setting does not affect 2D barcode reading Default Poor Quality 1D Reading Off Poor Quality 1D Reading On Poor Quality 1D Reading Off Poor Quality PDF Codes This setting improves the scanner s ability to read damaged or badly printed PDF codes by combining information from multiple images It is useful when a complete barcode canno...

Страница 46: ...nsmitted to the host system The scanner remains on scanning and decoding barcodes but the barcode data is not transmitted until the trigger is pressed When CodeGate is Off barcode data is transmitted when it is decoded Default CodeGate Off Out of Stand CodeGate Off Out of Stand CodeGate On Out of Stand Streaming Presentation Mode When in Streaming Presentation mode two modes are available Normal a...

Страница 47: ...f there have been no further trigger pulls the scanner reverts to the original hands free mode Scan the Hands Free Time Out barcode then scan the time out duration from 0 300 000 milliseconds from the Programming Chart beginning on page 211 then Save Default 5 000 ms Hands Free Time Out Reread Delay This sets the time period before the scanner can read the same barcode a second time Setting a rere...

Страница 48: ...tes that the time set for Reread Delay is used for both 1D and 2D barcodes Default 2D Reread Delay Off 2D Reread Delay Off Short 1000ms Medium 2000ms Long 3000ms Extra Long 4000ms Character Activation You may use a character sent from the host to trigger the scanner to begin scanning When the activation character is received the scanner continues scanning until either the Character Activation Time...

Страница 49: ... can be programmed either to remain on and scanning or to turn off When End Character Activation After Good Read is enabled the illumination turns off and stops scanning after a good read If you scan Do Not End Character Activation After Good Read the illumination remains on after a good read Do Not End Character Activation After Good Read End Character Activation After Good Read Character Activat...

Страница 50: ...Deactivation Mode On the ASCII Conversion Chart Code Page 1252 page 207 find the hex value that represents the character you want to use to terminate scanning Scan the following barcode then use the Programming Chart beginning on page 211239 to read the alphanumeric combination that represents that ASCII character Scan Save to finish Default 14 DC4 Deactivation Character Illumination Lights If you...

Страница 51: ...light will appear but the LEDs won t turn on until the delay time is over Default Off 1 millisecond 250 milliseconds 500 milliseconds Off no User Specified Aimer Delay If you want to set your own length for the duration of the delay scan the barcode below then set the time out by scanning digits 0 4 000 ms from the Programming Chart beginning on page 211 then Save Delay Duration Aimer Mode This fe...

Страница 52: ... Single Code Centering to target the barcode closest to the center of the image Singling out a barcode in this manner increases scanning accuracy when there are multiple barcodes close together Single Code Centering Custom Centering Use the following settings to customize your centering window If a barcode is not touched by a predefined window it will not be decoded or output by the scanner If cen...

Страница 53: ...om left or right of the centering window Then scan the percent you want to shift the centering window using digits from the Programming Chart beginning on page 239 then Save Default Centering 40 for Top and Left 60 for Bottom and Right Centering On Centering Off Top of Centering Window Bottom of Centering Window Left of Centering Window Right of Centering Window 0 Barcode 1 10 Barcode 2 20 30 40 5...

Страница 54: ...e out on page 52 while it searches for the high priority symbology If a high priority symbology is located during this period then that data is read immediately If the time out period expires before a high priority symbology is read the scanner will read any barcode in its view low priority or unspecified If there is no barcode in the scanner s view after the time out period expires then no data i...

Страница 55: ... up to 5 low priority symbologies Scan Save to save your selection Default None Low Priority Symbology Preferred Symbology Time out Once you have enabled Preferred Symbology and entered the high and low priority symbologies you must set the time out period This is the period of time the scanner will search for a high priority barcode after a low priority barcode has been encountered Scan the barco...

Страница 56: ...hanumeric barcodes see the Programming Chart beginning on page 211 1 If you are using barcodes to create your output sequence scan Enter Output Sequence on page 45 2 Code I D On the Symbology Charts on page 200 find the symbology to which you want to apply the output sequence format Make a note of the hex value for that symbology If you are using barcodes to create your output sequence scan the 2 ...

Страница 57: ...sing barcodes scan Discard page 215 to exit without saving any output sequence changes Output Sequence Editor Commands SEQBLK SEQPRE SEQSUF SEQSEP SEQTTS1 SEQSAT SEQTIM SEQIPR SEQISU SEQISE TRGSTO FF Sequence editor start command Add prefix to complete output sequences Add suffix to complete output sequences Add separators to complete output sequences Transmit partial sequence Define satisfactory ...

Страница 58: ...h for Code 39 9999 all lengths start character match for Code 39 43h C termination string for first code code identifier for Code 128 code length that must match for Code 128 9999 all lengths start character match for Code 128 54h T termination string for first code code identifier for PDF417 code length that must match for PDF417 9999 all lengths start character match for PDF417 4Dh M termination...

Страница 59: ...ch for Code 39 9999 all lengths start character match for Code 39 43h C termination string for first code code identifier for Code 128 code length that must match for Code 128 9999 all lengths start character match for Code 128 54h T termination string for first code code identifier for PDF417 code length that must match for PDF417 9999 all lengths start character match for PDF417 4Dh M terminatio...

Страница 60: ... an output sequence operation is terminated before all your output sequence criteria are met the barcode data acquired to that point is a partial sequence You can define how partial sequences are output using the same types of command strings you used to create output sequences Partial Sequence Example Three Symbologies with Separators but with a Damaged Code In this example you are scanning PDF41...

Страница 61: ...de 128 code length that must match for Code 128 9999 all lengths start character match for Code 128 54h T termination string for first code code identifier for PDF417 code length that must match for PDF417 9999 all lengths start character match for PDF417 4Dh M termination string for third code separator for each sequence 99 all symbologies left bracket right bracket separator for suffixes 99 all ...

Страница 62: ...t have been read during the current trigger session When the timeout expires the scanner sends all codes that it has been read in the order they appear in the sequence defined by SEQBLK To specify the timeout use the SEQTIM command followed by a list of timeouts in milliseconds Each timeout is specified as a 4 decimal digit terminated by FF The timeout value 9999 is special and indicates that the ...

Страница 63: ...scanner sends the codes in the order defined by SEQBLK Note To use the satisfactory subset feature you must supply a timeout for each code in the sequence using SEQTIM Satisfactory Subset of Full Sequence Timeout Example To specify a subset list its members using the SEQSAT command and terminate each subset with FF The members of each subset are specified as single hex digits corresponding to thei...

Страница 64: ...n page 46 When the output sequence is Off the barcode data is output to the host as the scanner decodes it Default Off Note This selection is unavailable when the Multiple Symbols Selection is turned on Required On Not Required Off Good Read Tone Output Sequences The scanner may be programmed to either beep or click in response to a good read of each barcode in an output sequence or to emit a beep...

Страница 65: ... the aiming beam Default Off On Off No Read With No Read turned On the scanner notifies you if a code cannot be read If using an EZConfig Scanning Tool Scan Data Window see page 159 an NR appears when a code cannot be read If No Read is turned Off the NR will not appear Default Off On Off If you want a different notation than NR for example Error or Bad Code you can edit the output message with NR...

Страница 66: ...nnot be read You must scan Video Reverse Off or Video Reverse and Standard Barcodes in order to read menu barcodes Note Images downloaded from the unit are not reversed This is a setting for decoding only Video Reverse Only Video Reverse and Standard Barcodes Video Reverse Off ...

Страница 67: ...r only with specific symbologies The following illustration shows the breakdown of a message string Points to Keep In Mind It is not necessary to build a message string The selections in this chapter are only used if you wish to alter the default settings Default prefix None Default suffix None A prefix or suffix may be added or cleared from one symbology or all symbologies You can add any prefix ...

Страница 68: ... or scan 9 9 for all symbologies To add the Code I D scan 5 C 8 0 To add the AIM I D scan 5 C 8 1 To add the serial number scan 5 C 8 8 To add a backslash scan 5 C 5 C Note When adding a backslash you must scan 5C twice once to create the leading backslash and then to create the backslash itself Step 4 Repeat Steps 2 and 3 for every prefix or suffix character Step 5 Scan Save to exit and save or s...

Страница 69: ...ine the 2 digit hex value from the Symbology Chart included in the Symbology Charts beginning on page 200 for the symbology from which you want to clear the prefix or suffix Step 3 Scan the 2 digit hex value from the Programming Chart beginning on page 211 or scan 9 9 for all symbologies Your change is automatically saved Add a Carriage Return Suffix to All Symbologies Scan the following barcode i...

Страница 70: ...ese key strokes interfere with your host s software application scan Disable to keep these ASCII control characters from being transmitted Default Enable Enable Disable Note You can also use a custom data format see Data Format beginning on page 59 to translate these characters into a more meaningful output Intercharacter Interfunction and Intermessage Delays Some terminals drop information charac...

Страница 71: ...upported in USB serial emulation User Specified Intercharacter Delay An intercharacter delay of up to 5000 milliseconds in 5ms increments may be placed after the transmission of a particular character of scanned data Scan the Delay Length barcode below then scan the number of 5ms delays from the Programming Chart beginning on page 211 then Save Next scan the Character to Trigger Delay barcode then...

Страница 72: ...n the Save barcode from the Programming Chart beginning on page 211 Intermessage Delay An intermessage delay of up to 5000 milliseconds in 5ms increments may be placed between each scan transmission Scan the Intermessage Delay barcode below then scan the number of 5ms delays and the Save barcode from the Programming Chart beginning on page 211 Intermessage Delay To remove this delay scan the Inter...

Страница 73: ...the order in which they are entered However the following list presents the order in which formats are applied 1 Specific Terminal ID Actual Code ID Actual Length 2 Specific Terminal ID Actual Code ID Universal Length 3 Specific Terminal ID Universal Code ID Actual Length 4 Specific Terminal ID Universal Code ID Universal Length 5 Universal Terminal ID Actual Code ID Actual Length 6 Universal Term...

Страница 74: ...lternate format scan 1 2 or 3 depending on which alternate format you are programming See Primary Alternate Data Formats on page 78 for further information Step 3 Terminal Type Refer to Terminal ID Table page 62 and locate the Terminal ID number for your PC Scan three numeric barcodes from the Programming Chart beginning on page 211 to program the scanner for your terminal ID you must enter 3 digi...

Страница 75: ... represent the command you want to enter Step 7 Scan Save to save your data format or Discard to exit without saving your changes Enter Data Format Save Discard Other Programming Selections Clear One Data Format This deletes one data format for one symbology If you are clearing the primary format scan 0 from the Programming Chart beginning on page 211 If you are clearing an alternate format scan 1...

Страница 76: ...eyboard HID 124 Mac Keyboard 125 PC Keyboard Japanese 134 Serial COM driver required 130 HID POS 131 USB SurePOS Handheld 128 USB SurePOS Tabletop 129 Serial RS232 000 Data Format Editor Commands When working with the Data Format Editor a virtual cursor is moved along your input data string The following commands are used to both move this cursor to different positions and to select replace and in...

Страница 77: ...x where nn stands for the numeric value 00 99 for the number of characters and xx stands for the insert character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page 203 for decimal hex and character codes F2 Example Send a number of characters Send the first 10 characters from the barcode above followed by a carriage return Command string F2100D F2 ...

Страница 78: ...for decimal hex and character codes F3 Example Send all characters up to a particular character Using the barcode above send all characters up to but not including D followed by a carriage return Command string F3440D F3 is the Send all characters up to a particular character command 44 is the hex value for a D 0D is the hex value for a CR The data is output as 1234567890ABC CR Send all characters...

Страница 79: ... character included Syntax E9nn where nn stands for the numeric value 00 99 for the number of characters that will not be sent at the end of the message Insert a character multiple times F4 Send xx character nn times in the output message leaving the cursor in the current position Syntax F4xxnn where xx stands for the insert character s hex value for its ASCII code and nn is the numeric value 00 9...

Страница 80: ...g on page 203 for decimal hex and character codes B9 and BA Example Look for the string AB and insert 2 asterisks Using the barcode above send all characters up to but not including AB Insert 2 asterisks at that point and send the rest of the data with a carriage return after Command string B900024142BA00022A2AF10D B9 is the Send all characters up to a string command 0002 is the length of the stri...

Страница 81: ...nd B4 Example Insert the symbology name and length Send the symbology name and length before the barcode data from the barcode above Break up these insertions with spaces End with a carriage return Command string B3F42001B4F42001F10D B3 is the Insert symbology name command F4 is the Insert a character multiple times command 20 is the hex value for a space 01 is the number of times the space charac...

Страница 82: ...B5 the command 01 number of key press events without the key modifier 02 is the key modifier for Shift Right and 1F is the a key If a lower case a were to be inserted B501001F would be entered If there are three keystrokes the syntax would change from B5xxssnn for one keystroke to B5xxssnnssnnssnn An example that would insert abc is as follows B503001F00320030F833 Note Key modifiers can be added t...

Страница 83: ...sor position Syntax F6nn where nn is the numeric value 00 99 for the number of characters the cursor should be moved back Move the cursor to the beginning F7 Move the cursor to the first character in the input message Syntax F7 FE and F7 Example Manipulate barcodes that begin with a 1 Search for barcodes that begin with a 1 If a barcode matches move the cursor back to the beginning of the data and...

Страница 84: ...x F8xx where xx stands for the search character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page 203 for decimal hex and character codes F8 Example Send barcode data that starts after a particular character Search for the letter D in barcodes and send all the data that follows including the D Using the barcode above Command string F844F10D F8 is t...

Страница 85: ...9 and S consists of the ASCII hex value of each character in the match string For example B0000454657374 will search forward for the first occurrence of the 4 characters string Test Refer to the ASCII Conversion Chart Code Page 1252 beginning on page 203 for decimal hex and character codes B0 Example Send barcode data that starts after a string of characters Search for the letters FGH in barcodes ...

Страница 86: ...rom the current cursor position leaving the cursor pointing to the non xx character Syntax E6xx where xx stands for the search character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page 203 for decimal hex and character codes E6 Example Remove zeros at the beginning of barcode data This example shows a barcode that has been zero filled You may wan...

Страница 87: ...mands When the FC command is encountered the suppress function is terminated The cursor is not moved by the FB command Syntax FBnnxxyy zz where nn is a count of the number of suppressed characters in the list and xxyy zz is the list of characters to be suppressed FB Example Remove spaces in barcode data This example shows a barcode that has spaces in the data You may want to remove the spaces befo...

Страница 88: ...e barcode has characters that the host application does not want included you can use the E4 command to replace those characters with something else In this example you will replace the zeros in the barcode above with carriage returns Command string E402300DF10D E4 is the Replace characters command 02 is the total count of characters to be replaced plus the replacement characters 0 is replaced by ...

Страница 89: ...454657374 will compare the string at the current cursor position with the 4 character string Test Refer to the ASCII Conversion Chart Code Page 1252 beginning on page 203 for decimal hex and character codes Check for a number EC Check to make sure there is an ASCII number at the current cursor position The format is aborted if the character is not numeric EC Example Only output the data if the bar...

Страница 90: ...data is output as 1234AB If this barcode is read the data is output as AB1234 CR Insert a delay EF Inserts a delay of up to 49 995 milliseconds in multiples of 5 starting from the current cursor position Syntax EFnnnn where nnnn stands for the delay in 5ms increments up to 9999 This command can only be used with keyboard emulation Discard Data B8 Discards types of data For example you may want to ...

Страница 91: ...d suffixes are transmitted Data Formatter On Not Required Drop Prefix Suffix Scanned data is modified according to your data format If a data format is found for a particular symbol those prefixes and suffixes are not transmitted If a data format is not found for that symbol the prefixes and suffixes are transmitted Data Format Required Keep Prefix Suffix Scanned data is modified according to your...

Страница 92: ...doesn t match your required data format the scanner normally generates an error tone However you may want to continue scanning barcodes without hearing the error tone If you scan the Data Format Non Match Error Tone Off barcode data that doesn t conform to your data format is not transmitted and no error tone will sound If you wish to hear the error tone when a non matching barcode is found scan t...

Страница 93: ...Scan Data Format Change You can also switch between data formats for a single scan The next barcode is scanned using an alternate data format then reverts to the format you have selected above either Primary 1 2 or 3 For example you may have set your device to the data format you saved as Data Format 3 You can switch to Data Format 1 for a single trigger pull by scanning the Single Scan Data Forma...

Страница 94: ...80 HH490 User Guide Single Scan Data Format 2 Single Scan Data Format 3 ...

Страница 95: ... Code 93 Data Matrix Digimarc Barcode DotCode EAN JAN 13 EAN JAN 8 GS1 Composite Codes GS1 DataBar Expanded GS1 DataBar Limited GS1 DataBar Omnidirectional GS1 Emulation GS1 128 Interleaved 2 of 5 Korea Post Label Code Matrix 2 of 5 MaxiCode MicroPDF417 MSI NEC 2 of 5 Postal Codes 2D Postal Codes Linear PDF417 QR Code Straight 2 of 5 IATA two bar start stop Straight 2 of 5 Industrial three bar sta...

Страница 96: ...er to read fixed length barcode data This helps reduce the chances of a misread Example Decode only those barcodes with a count of 9 20 characters Min length 09 Max length 20 Example Decode only those barcodes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the barcodes included in the explanation of the symbolog...

Страница 97: ...heck characters Default No Check Character No Check Character indicates that the scanner reads and transmits barcode data with or without a check character When Check Character is set to Validate and Transmit the scanner will only read Codabar barcodes printed with a check character and will transmit this character at the end of the scanned data When Check Character is set to Validate but Don t Tr...

Страница 98: ... with the D characters omitted Select Require to prevent the scanner from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters On Off Require Codabar Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 81 for additional information Minimum and Maximum lengths...

Страница 99: ...identify the leading and trailing ends of the barcode You may either transmit or not transmit Start Stop characters Default Don t Transmit Transmit Don t Transmit Code 39 Check Character No Check Character indicates that the scanner reads and transmits barcode data with or without a check character When Check Character is set to Validate but Don t Transmit the unit only reads Code 39 barcodes prin...

Страница 100: ...ength Description page 82 for additional information Minimum and Maximum lengths 0 48 Minimum Default 0 Maximum Default 48 Minimum Message Length Maximum Message Length Code 39 Append This function allows the scanner to append the data from several Code 39 barcodes together before transmitting them to the host computer When the scanner encounters a Code 39 barcode with the append trigger character...

Страница 101: ...ple V will be decoded as the ASCII character SYN and C will be decoded as the ASCII character Default Off Full ASCII Table NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B 2 2 B B R R b B r R ETX C DC3 S C 3 3 C C S S c C s S EOT D DC4 T D 4 4 D D T T d D t T ENQ E NAK U E 5 5 E E U U e E u U ACK F SYN V F 6 6 F F V V f F v V BEL G ETB W G 7 7 G G W W g G w W BS...

Страница 102: ...because the barcode being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the barcode below select the code page with which the barcodes were created see ISO 2022 ISO 646 Character Replacements on page 208 and scan the value and the Save barcode from the Programming Chart beginning on page 211 The data characters should th...

Страница 103: ...date and Transmit the scanner only reads Interleaved 2 of 5 barcodes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit No Check Digit Validate but Don t Transmit Validate and Transmit Interleaved 2 of 5 Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 82 for additional informatio...

Страница 104: ... the scanned data When Check Digit is set to Validate and Transmit the scanner only reads NEC 2 of 5 barcodes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit No Check Digit Validate but Don t Transmit Validate and Transmit NEC 2 of 5 Message Length Scan the barcodes below to change the message length Refer to Message Length Description ...

Страница 105: ... Minimum Default 0 Maximum Default 80 Minimum Message Length Maximum Message Length Code 93 Append This function allows the scanner to append the data from several Code 93 barcodes together before transmitting them to the host computer When this function is enabled the scanner stores those Code 93 barcodes that start with a space excluding the start and stop symbols and does not immediately transm...

Страница 106: ... barcode being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the barcode below select the code page with which the barcodes were created see ISO 2022 ISO 646 Character Replacements on page 208 and scan the value and the Save barcode from the Programming Chart beginning on page 211 The data characters should then appear p...

Страница 107: ...t 2 of 5 IATA On Off On Off Straight 2 of 5 IATA Redundancy If you are encountering errors when reading Straight 2 of 5 IATA barcodes you may want to adjust the redundancy count Redundancy adjusts the number of times a barcode is decoded before transmission which may reduce the number of errors Note that the higher the redundancy count the longer it will take to decode the barcode To adjust the re...

Страница 108: ...inimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Minimum Message Length Maximum Message Length Matrix 2 of 5 Default All Matrix 2 of 5 Settings Matrix 2 of 5 On Off On Off Matrix 2 of 5 Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 82 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maxi...

Страница 109: ...h Maximum Message Length Code 11 Default All Code 11 Settings Code 11 On Off On Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 barcodes Default Two Check Digits One Check Digit Two Check Digits ...

Страница 110: ...ould remain disabled If you are enabling Codablock F see Codablock F on page 136 you should disable Code 122 ISBT 128 Concatenation In 1994 the International Society of Blood Transfusion ISBT ratified a standard for communicating critical blood information in a uniform manner The use of ISBT formats requires a paid license The ISBT 128 Application Specification describes 1 the critical data elemen...

Страница 111: ...educe the number of errors Note that the higher the redundancy count the longer it will take to decode the barcode To adjust the redundancy scan the Code 128 Redundancy barcode below then scan a redundancy count between 0 and 10 on the Programming Chart beginning on page 211 Then scan the Save barcode Default 0 Code 128 Redundancy Code 128 Message Length Scan the barcodes below to change the messa...

Страница 112: ...lt On On Off Code 128 Code Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the barcode below select the code page with which the barcodes were created see ...

Страница 113: ...s below to change the message length Refer to Message Length Description page 82 for additional information Minimum and Maximum lengths 1 80 Minimum Default 1 Maximum Default 80 Minimum Message Length Maximum Message Length Telepen Default All Telepen Settings Telepen On Off On Off ...

Страница 114: ...attern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output AIM Telepen Output Original Telepen Output Telepen Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 82 for additional information Minimum and Maximum lengths 1 60 Minimum Default 1 Maximum Default 60 Minimum Message Len...

Страница 115: ...igit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On On Off UPC A Number System The numeric system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but can be programmed so it is not transmitted Off Default On On Off ...

Страница 116: ...on a 2 or 5 digit addenda listed on page 101 Default Not Required Required Not Required Addenda Timeout You can set a time during which the scanner looks for an addenda If an addenda is not found within this time period the data can be either transmitted or discarded based on the setting you are using for UPC A Addenda Required Set the length in milliseconds for this timeout by scanning the barcod...

Страница 117: ...h Extended Coupon Code When left on the default setting Off the scanner treats Coupon Codes and Extended Coupon Codes as single barcodes If you scan the Allow Concatenation code when the scanner sees the coupon code and the extended coupon code in a single scan it transmits both as one symbologies Otherwise it transmits the first coupon code it reads If you scan the Require Concatenation code the ...

Страница 118: ... the timeout from 0 120 milliseconds by scanning digits from the Programming Chart beginning on page 211 of this manual then Save Default 120 Note The Addenda Timeout setting is applied to all addenda and coupon code searches Addenda Timeout Coupon GS1 DataBar Output If you scan coupons that have both UPC and GS1 Databar codes you may wish to scan and output only the data from the GS1 Databar code...

Страница 119: ... read codes that lead with the 1 number system use UPC E1 page 106 Default On UPC E0 On UPC E0 Off UPC E0 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off On Off UPC E0 Addenda Required When Required is scanned the scanner will only read UPC E barcodes that have addenda Default Not Required Required Not Required ...

Страница 120: ...timeout from 0 120 milliseconds by scanning digits from the Programming Chart beginning on page 211 of this manual then Save Default 120 Note The Addenda Timeout setting is applied to all addenda and coupon code searches Addenda Timeout UPC E0 Addenda Separator When this feature is On there is a space between the data from the barcode and the data from the addenda When turned Off there is no space...

Страница 121: ...his selection adds 2 or 5 digits to the end of all scanned UPC E data Default Off for both 2 Digit and 5 Digit Addenda 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off UPC E1 Most U P C barcodes lead with the 0 number system For these codes use UPC E0 page 103 If you need to read codes that lead with the 1 number system use the UPC E1 On selection Default Off UPC E1 On...

Страница 122: ...ected UPC A barcodes are converted to 13 digits EAN 13 codes by adding a zero to the front When Do not Convert UPC A is selected UPC A codes are read as UPC A UPC A Converted to EAN 13 Do not Convert UPC A EAN JAN 13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On ...

Страница 123: ...ed EAN JAN 13 data Default Off for both 2 Digit and 5 Digit Addenda 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off EAN JAN 13 Addenda Required When Required is scanned the scanner will only read EAN JAN 13 barcodes that have addenda Default Not Required Required Not Required ...

Страница 124: ...are transmitted depending on the setting you are using for EAN JAN 13 Addenda Required Default Don t Require 5 Digit Addenda Don t Require 5 Digit Addenda Require 5 Digit Addenda EAN 13 Beginning with 378 379 Addenda Required This setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN 13 barcodes that begin with a 378 or 379 The following settings ...

Страница 125: ...13 barcodes that begin with a 414 or 419 must have a 2 digit addenda a 5 digit addenda or a combination of these addenda The EAN 13 barcode with the addenda is then transmitted as a single concatenated barcode If the required addenda is not found within the Addenda Timeout period the EAN 13 barcode is discarded Don t Require Addenda If you have selected Require Addenda and you want to disable this...

Страница 126: ...enda a 5 digit addenda or a combination of these addenda The EAN 13 barcode with the addenda is then transmitted as a single concatenated barcode If the required addenda is not found within the Addenda Timeout period the EAN 13 barcode is discarded Don t Require Addenda If you have selected Require Addenda and you want to disable this feature scan Don t Require Addenda EAN 13 barcodes are transmit...

Страница 127: ...or EAN JAN 13 Addenda Required Default Don t Require 2 Digit Addenda Don t Require 2 Digit Addenda Require 2 Digit Addenda EAN 13 Beginning with 978 Addenda Required These settings program the scanner to require a 5 digit addenda only on EAN 13 barcodes that begin with 978 The following settings can be programmed Require 5 Digit Addenda All EAN 13 barcodes that begin with 978 must have a 5 digit a...

Страница 128: ...ble this feature scan Don t Require 5 Digit Addenda EAN 13 barcodes are transmitted depending on the setting you are using for EAN JAN 13 Addenda Required Default Don t Require 5 Digit Addenda Don t Require 5 Digit Addenda Require 5 Digit Addenda Addenda Timeout You can set a time during which the scanner looks for an addenda If an addenda is not found within this time period the data can be eithe...

Страница 129: ...ned Off there is no space Default On On Off Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code page 116 ISBN Translate When On is scanned EAN 13 Bookland symbols are translated into their equivalent ISBN number format Default Off On Off EAN JAN 8 Default All EAN JAN 8 Settings EAN JAN 8 On Off On ...

Страница 130: ...fault On On Off EAN JAN 8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 8 data Default Off for both 2 Digit and 5 Digit Addenda 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off EAN JAN 8 Addenda Required When Required is scanned the scanner will only read EAN JAN 8 barcodes that have addenda Default Not Required ...

Страница 131: ...nds for this timeout by scanning the barcode below then setting the timeout from 0 120 milliseconds by scanning digits from the Programming Chart beginning on page 211 of this manual then Save Default 120 Note The Addenda Timeout setting is applied to all addenda and coupon code searches Addenda Timeout EAN JAN 8 Addenda Separator When this feature is On there is a space between the data from the ...

Страница 132: ...inted with the specified type check character s and will transmit the character s at the end of the scanned data When Check Character is set to Validate Type 10 11 but Don t Transmit the unit will only read MSI barcodes printed with the specified type check character s but will not transmit the check character s with the scanned data Validate Type 10 but Don t Transmit Validate Type 10 and Transmi...

Страница 133: ... below to change the message length Refer to Message Length Description page 82 for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Minimum Message Length Maximum Message Length GS1 DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings GS1 DataBar Omnidirectional On Off On Off ...

Страница 134: ...ataBar Expanded Default All GS1 DataBar Expanded Settings GS1 DataBar Expanded On Off On Off GS1 DataBar Expanded Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 82 for additional information Minimum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 74 ...

Страница 135: ...cal codes page 87 Trioptic Code must be off Trioptic Code is used for labeling magnetic storage media On Off Codablock A Default All Codablock A Settings Codablock A On Off On Off If you are reading Code 39 barcodes Codablock A should remain disabled If you are enabling Codablock A you should disable Code 39 see Code 39 on page 85 ...

Страница 136: ...imum Message Length Codablock F Default All Codablock F Settings Codablock F On Off On Off If you are reading Code 128 barcodes Codablock F should remain disabled If you are enabling Codablock F you should disable Code 128 see Code 128 on page 96 Codablock F Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 82 for additional information Mi...

Страница 137: ...d in libraries Default Off On Off PDF417 Default All PDF417 Settings PDF417 On Off On Off PDF417 Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 82 for additional information Minimum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 ...

Страница 138: ... is an implementation of PDF417 capable of encoding very large amounts of data into multiple PDF417 barcodes When this selection is enabled these multiple barcodes are assembled into a single data string Default On On Off MicroPDF417 Default All MicroPDF417 Settings MicroPDF417 On Off On Off ...

Страница 139: ...te Codes Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology GS1 Composite symbologies allow for the co existence of symbologies already in use Default Off On Off UPC EAN Version Scan the UPC EAN Version On barcode to decode GS1 Composite symbols that have a U P C or an EAN linear component This does not affect GS1 Composite symbols wit...

Страница 140: ... 8 ITF 14 GS1 128 and GS1 DataBar and GS1 Composites Any application that accepts GS1 data can be simplified since it only needs to recognize one data carrier type If GS1 128 Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16 digits If the AIM ID is enabled the value will be the GS1 128 AIM ID C1 see Symbology Charts on page 200 If GS1 DataBar Emulation is scanned ...

Страница 141: ...s a composite code since it has a Code 39 linear component and a MicroPDF417 stacked code component All barcode readers are capable of reading the Code 39 linear component The MicroPDF417 component can only be decoded if TLC39 On is selected The linear component may be decoded as Code 39 even if TLC39 is off Default Off On Off QR Code Default All QR Code Settings ...

Страница 142: ... When the scanner encounters an QR Code barcode with the append trigger character s it buffers the number of QR Code barcodes determined by information encoded in those barcodes Once the proper number of codes is reached the data is output in the order specified in the barcodes There are 3 ways to scan appended QR Code One Scan Pull the trigger one time and all appended QR Codes in the same image ...

Страница 143: ...ing of character codes to characters If the data received does not display with the proper characters it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the barcode below select the code page with which the barcodes were created see ISO 2022 ISO 646 Character Replacements on page 208 and sc...

Страница 144: ... Default Poor Quality DotCodes Off Poor Quality DotCodes On Poor Quality DotCodes Off DotCodeMessageLength Scan the barcodes below to change the message length Refer to Message Length Description page 82 for additional information Minimum and Maximum lengths 1 2400 Minimum Default 1 Maximum Default 2400 Minimum Message Length Maximum Message Length ...

Страница 145: ...coder will read the number of attempts set by the Digimarc Decoder Attempts and then will use both ID and Digimarc decoders When Digimarc Barcode is set to Uses Digimarc Decoder then Both Decoders the Digimarc decoder will read the number of attempts set by the Digimarc Decoder Attempts and then will use both ID and Digimarc decoders When Digimarc Barcdoe is set to Uses ID Decoder then Alternates ...

Страница 146: ...Digimarc Decoder then Alternates Decoders Data Matrix Default All Data Matrix Settings Data Matrix On Off On Off DirectPartMarkingDecoding If you are having trouble reading Direct Part Marking DPM barcodes scan Dotpeen DPM Decoding for Dotpeen codes or scan Reflective Etched DPM Decoding for reflective etched codes Default Disable DPM Decoding ...

Страница 147: ...ata Matrix Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the barcode below select the code page with which the barcodes were created see ISO 2022 ISO 646 Char...

Страница 148: ...sage Length Scan the barcodes below to change the message length Refer to Message Length Description page 82 for additional information Minimum and Maximum lengths 1 150 Minimum Default 1 Maximum Default 150 Minimum Message Length Maximum Message Length Aztec Code Default All Aztec Code Settings ...

Страница 149: ... Message Length Maximum Message Length Aztec Append This function allows the scanner to append the data from several Aztec barcodes together before transmitting them to the host computer When the scanner encounters an Aztec barcode with the append trigger character s it buffers the number of Aztec barcodes determined by information encoded in those barcodes Once the proper number of codes is reach...

Страница 150: ... which the barcodes were created see ISO 2022 ISO 646 Character Replacements on page 208 and scan the value and the Save barcode from the Programming Chart beginning on page 211 The data characters should then appear properly Aztec Code Page Chinese Sensible Han Xin Code Default All Han Xin Settings Han Xin Code On Off On Off Han Xin Code Message Length Scan the barcodes below to change the messag...

Страница 151: ...ons that are allowed Only one 2D postal code selection can be active at a time If you scan a second 2D postal code selection the first selection is overwritten Default 2D Postal Codes Off 2D Postal Codes Off Single 2D Postal Codes Australian Post On British Post On Canadian Post On Intelligent Mail Barcode On Japanese Post On KIX Post On ...

Страница 152: ...Also see Postnet Check Digit page 139 Postnet with B and B Fields On InfoMail On Combination 2D Postal Codes InfoMail and British Post On Intelligent Mail Barcode and Postnet with B and B Fields On Postnet and Postal 4i On Postnet and Intelligent Mail Barcode On Postal 4i and Intelligent Mail Barcode On ...

Страница 153: ... On Planet Code and Intelligent Mail Barcode Planet Code Postnet and Postal 4i On Planet Code Postnet and Intelligent Mail Barcode On Planet Code Postal 4i and Intelligent Mail Barcode On Postnet Postal 4i and Intelligent Mail Barcode On Planet Code Postal 4i and Postnet with B and B Fields On Planet Code Intelligent Mail Barcode and Postnet with B and B Fields On ...

Страница 154: ...d B Fields On Planet Code Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of Planet Code data Default Don t Transmit Transmit Check Digit Don t Transmit Check Digit Postnet Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of Postnet data Default Don t Transmit Transmit Check Digit Don...

Страница 155: ...able causes the field to be interpreted as alphanumeric data using the C Table Refer to the Australian Post Specification Tables Combination C and N Tables causes the field to be interpreted using either the C or N Tables Bar Output Numeric N Table Alphanumeric C Table Combination C and N Tables Postal Codes Linear The following lists linear postal codes Any combination of linear postal code selec...

Страница 156: ...gth Scan the barcodes below to change the message length Refer to Message Length Description page 82 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Minimum Message Length Maximum Message Length Korea Post Default All Korea Post Settings Korea Post On Off ...

Страница 157: ...n page 82 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 Minimum Message Length Maximum Message Length Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted or not Default Don t Transmit Transmit Check Digit Don t Transmit Check Digit ...

Страница 158: ...144 HH490 User Guide ...

Страница 159: ...anent setting for the scanner Command Syntax Multiple modifiers and commands can be issued within one sequence If additional modifiers are to be applied to the same command just add the modifiers to that command For example to add 2 modifiers to the Image Snap command such as setting the Imaging Style to 1P and the Wait for Trigger to 1T you would enter IMGSNP1P1T Note After processing an image ca...

Страница 160: ...SNP command is processed The image snap command has many different modifiers that can be used to change the look of the image in memory Any number of modifiers may be appended to the IMGSNP command Example You can use the following command to snap an image increase the gain and have the beeper sound once the snap is complete IMGSNP2G1B IMGSNP Modifiers P Imaging Style This sets the Image Snap styl...

Страница 161: ...uments such as ID cards especially when the scanner is in a stand LED illumination 1L is preferred when the scanner is handheld LED State is not available when using Decoding Style 0P 0L LEDs off default 1L LEDs on E Exposure Exposure is used in Manual Style only 2P and allows you to set the exposure time This is similar to setting a shutter speed on a camera The exposure time determines how long ...

Страница 162: ...d 1G No gain default 2G Medium gain 4G Heavy gain 8G Maximum gain Example Gain at 1G Gain at 4G Gain at 8G W Target White Value Sets the target for the median grayscale value in the captured image For capturing close up images of high contrast documents a lower setting such as 75 is recommended Higher settings result in longer exposure times and brighter images but if the setting is too high the i...

Страница 163: ...e Tries is only available when using Photo Style 1P Default 6 nU Range 0 10 Target Set Point Percentage Sets the target point for the light and dark values in the captured image A setting of 75 means 75 of the pixels are at or below the target white value and 25 of the pixels are above the target white value Altering this setting from the default is not recommended under normal circumstances To al...

Страница 164: ...nsmitted but do not affect the image in memory Any number of modifiers may be appended to the IMGSHP command Example You can use the following command to snap and ship a bitmap image with gamma correction and document image filtering IMGSNP IMGSHP8F75K26U IMGSHP Modifiers A Infinity Filter Enhances pictures taken from very long distances greater than 10 feet or 3m The Infinity Filter should not be...

Страница 165: ...yscale image default 1D 1 bit per pixel black and white image E Edge Sharpen An edge sharpen filter cleans up the edges of an image making it look cleaner and sharper While edge sharpening does make the image look cleaner it also removes some fine detail from the original image The strength of the edge sharpen filter can be entered from 1 to 24 Entering a 23E gives the sharpest edges but also incr...

Страница 166: ...sed TIFF grayscale Uncompressed binary upper left to lower right 1 pixel bit 0 padded end of line Uncompressed grayscale upper left to lower right bitmap format JPEG image default BMP format lower right to upper left uncompressed BMP Uncompressed raw image H Histogram Stretch Increases the contrast of the transmitted image Not available with some image formats 0H 1H No stretch default Histogram st...

Страница 167: ...is flips picture upside down Invert around the Y axis flips picture left to right Example Image not inverted Image with Invert Image set to 1ix Image with Invert Image set to 1iy IF Noise Reduction Used to reduce the salt and pepper noise in an image 0if 1if No salt and pepper noise reduction default Salt and pepper noise reduction Example Noise Reduction Off 0if Noise Reduction On 1if ...

Страница 168: ...Rotate set to 1ir Image Rotate set to 3ir J JPEG Image Quality Sets the desired quality when the JPEG image format is selected Higher numbers result in higher quality but larger files Smaller numbers result in greater amounts of lossy compression faster transmission times lower quality but smaller files Default 50 nJ 0J 100J Image is compressed as much as possible while preserving quality factor o...

Страница 169: ...n set to 255K L R T B M Image Cropping Ships a window of the image by specifying the left right top and bottom pixel coordinates Device columns are numbered 0 through 1279 and device rows are numbered 0 through 959 nL The left edge of the shipped image corresponds to column n of the image in memory Range 000 843 Default 0 nR The right edge of the shipped image corresponds to column n 1 of the imag...

Страница 170: ... It addresses the protocol used to send the data Hmodem which is an Xmodem 1K variant that has additional header information and the format of the image data that is sent 0P 2P 3P 4P None raw data None default for USB Hmodem compressed default for RS232 Hmodem S Pixel Ship Pixel Ship sizes an image in proportion to its original size It decimates the image by shipping only certain regularly spaced ...

Страница 171: ...rd E Edge Sharpen command see page 150 This filter also works well when shipping pure black and white images 1 bit per pixel The optimal setting is 26U 0U 26U nU Document image filter off default Apply document image filter for typical document image Apply document image filter using grayscale threshold n Use lower numbers when the image contrast is lower 1U will have a similar effect to setting E...

Страница 172: ...age or key type A low key image has detail concentrated in the shadows a high key image has detail concentrated in the highlights and an average key image has detail concentrated in the midtones This modifier ships the histogram for an image 0W 1W Don t ship histogram default Ship histogram Example Image used for histogram Histogram of image ...

Страница 173: ...porary setting that will be removed when the unit is power cycled Add Code I D Prefix to All Symbologies Temporary Show Software Revision Scan the barcode below to output the current software revision unit serial number and other product information for both the scanner Show Boot Software Revision Show App Software Revision Test Menu When you scan the Test Menu On code then scan a programming code...

Страница 174: ... on the scanner connected to your PC EZConfig for Scanning allows you to download upgrades to the scanner s firmware change programmed parameters and create and print programming barcodes Using EZConfig for Scanning you can even save open the programming parameters This saved file can be e mailed or if required you can create a single barcode that contains all the customized programming parameters...

Страница 175: ...etup version of EZConfig for Scanning 4 Open EZConfig to configure your scanner Reset the Factory Defaults Caution This selection erases all your settings and resets the scanner to the original factory defaults It also disables all plugins If you aren t sure what programming options are in your scanner or you ve changed some options and want to restore the scanner to factory default settings first...

Страница 176: ...90 User Guide Remove Custom Defaults Activate Defaults Note The Menu Commands beginning on page 167 list the factory default settings for each of the commands indicated by an asterisk on the programming pages ...

Страница 177: ...owing conventions are used for menu and query command descriptions parameter A label representing the actual value you should send as part of a command option Data bold An optional part of a command Alternatives in a command Names of menus menu commands buttons dialog boxes and win dows that appear on the screen Menu Command Syntax Menu commands have the following syntax spaces have been used for ...

Страница 178: ...g Storage A single character that specifies the storage table to which the com mand is applied An exclamation point performs the command s operation on the device s volatile menu configuration table A period performs the command s operation on the device s non volatile menu configuration table Use the non volatile table only for semi permanent changes you want saved through a power cycle Query Com...

Страница 179: ...quence Only the Tag SubTag and Data fields must be repeated for each command in the sequence If additional commands are to be applied to the same Tag then the new command sequence is separated with a comma and only the SubTag and Data fields of the additional command are issued If the additional command requires a different Tag field the command is separated from previous commands by a semicolon R...

Страница 180: ... for Codabar Coding Enable CBRENA is 1 or on Example What is the device s current setting for Codabar Coding Enable Enter Response cbrena CBRENA1 ACK This response indicates that the device s Codabar Coding Enable CBRENA is set to 1 or on Example What are the device s settings for all Codabar selections Enter Response cbr CBRENA1 ACK SSX0 ACK CK20 ACK CCT1 ACK MIN2 ACK MAX60 ACK DFT ACK This respo...

Страница 181: ...e has been read until the deactivate command is sent or until the serial time out has been reached see Read Time Out on page 28 for a description and the serial command on page 167 Reset the Custom Defaults If you want the custom default settings restored to your scanner scan the Activate Custom Defaults barcode below This resets the scanner to the custom default settings If there are no custom de...

Страница 182: ...ac PAP125 6 USB Japanese Keyboard PC TERMID134 6 USB HID PAP131 7 USB Serial TERMID130 7 CTS RTS Emulation On USBCTS1 7 CTS RTS Emulation Off USBCTS0 7 ACK NAK Mode On USBACK1 8 ACK NAK Mode Off USBACK0 8 Remote MasterMind for USB On REMIFC1 8 Remote MasterMind for USB Off REMIFC0 8 Program Keyboard Country U S A KBDCTY0 8 Albania KBDCTY35 8 Azeri Cyrillic KBDCTY81 8 Azeri Latin KBDCTY80 8 Belarus...

Страница 183: ...eek 319 KBDCTY62 11 Greek Latin KBDCTY63 11 Greek MS KBDCTY66 11 Greek Polytonic KBDCTY60 11 Hebrew KBDCTY12 11 Hungarian 101 key KBDCTY50 11 Hungary KBDCTY19 11 Iceland KBDCTY75 11 Irish KBDCTY73 11 Italian 142 KBDCTY56 12 Italy KBDCTY5 12 Japan ASCII KBDCTY28 12 Kazakh KBDCTY78 12 Kyrgyz Cyrillic KBDCTY79 12 Latin America KBDCTY14 12 Latvia KBDCTY42 12 Latvia QWERTY KBDCTY43 12 Lithuania KBDCTY4...

Страница 184: ...CTY85 14 Turkey F KBDCTY27 14 Turkey Q KBDCTY24 15 Ukrainian KBDCTY76 15 United Kingdom KBDCTY7 15 United Stated Dvorak right KBDCTY89 15 United States Dvorak left KBDCTY88 15 United States Dvorak KBDCTY87 15 United States International KBDCTY30 15 Uzbek Cyrillic KBDCTY77 15 ALT Mode Off KBDALT0 15 3 Characters KBDALT6 16 4 Characters KBDALT7 16 Keyboard Style Regular KBDSTY0 16 Caps Lock KBDSTY1 ...

Страница 185: ...PS 232BAD7 19 57600 BPS 232BAD8 19 115200 BPS 232BAD9 19 Word Length Data Bits Stop Bits and Parity 7 Data 1 Stop Parity Even 232WRD3 20 7 Data 1 Stop Parity None 232WRD0 20 7 Data 1 Stop Parity Odd 232WRD6 20 7 Data 2 Stop Parity Even 232WRD4 20 7 Data 2 Stop Parity None 232WRD1 20 7 Data 2 Stop Parity Odd 232WRD7 20 8 Data 1 Stop Parity Even 232WRD5 20 8 Data 1 Stop Parity None 232WRD2 20 8 Data...

Страница 186: ... 24 Beeper Volume Good Read Off BEPLVL0 24 Low BEPLVL1 24 Medium BEPLVL2 24 High BEPLVL3 24 Beeper Pitch Good Read Frequency Low 1600 Hz min 400 Hz BEPFQ11600 25 Medium 2700 Hz BEPFQ12700 25 High 4200 Hz max 9000 Hz BEPFQ14200 25 Beeper Pitch Error Frequency Razz 250 Hz min 200 Hz BEPFQ2800 25 Medium 3250 Hz BEPFQ23250 25 High 4200 Hz max 9000 Hz BEPFQ24200 25 Beeper Duration Good Read Normal Beep...

Страница 187: ...1 30 Presentation Centering Off PDCWIN0 30 Left of Presentation Centering Window 40 PDCLFT 31 Right of Presentation Centering Window 60 PDCRGT 31 Top of Presentation Centering Window 40 PDCTOP 30 Bottom of Presentation Centering Window 60 PDCBOT 30 Poor Quality Codes Poor Quality 1D Reading On DECLDI1 31 Poor Quality 1D Reading Off DECLDI0 31 Poor Quality PDF Reading On PDFXPR10 31 Poor Quality PD...

Страница 188: ...30 000 ms HSTCDT 36 Character Deactivation Mode Off HSTDEN0 36 On HSTDEN1 36 Deactivation Character Range 0 255 14 DC4 HSTDCH 36 Illumination Lights Lights On SCNLED1 36 Lights Off SCNLED0 36 Aimer Delay 1 millisecond SCNDLY1 37 250 milliseconds SCNDLY250 37 500 milliseconds SCNDLY500 37 Off no delay SCNDLY0 37 User Specified Aimer Delay Range 0 4 000 ms SCNDLY 37 Aimer Mode Off SCNAIM0 37 On SCNA...

Страница 189: ...ick Each Code in Sequence BEPSIN1 50 Good Read Beep Partial Sequence Output BEPISE0 50 Error Tone Partial Sequence Output BEPISE1 50 Multiple Symbols On SHOTGN1 51 Off SHOTGN0 51 No Read On SHWNRD1 51 Off SHWNRD0 51 Video Reverse Video Reverse Only VIDREV1 52 Video Reverse and Standard Barcodes VIDREV2 52 Video Reverse Off VIDREV0 52 Working Orientation Upright ROTATN0 Vertical Bottom to Top Rotat...

Страница 190: ...at Required Keep Prefix Suffix DFM_EN2 78 Data Formatter On Not Required Drop Prefix Suffix DFM_EN3 78 Data Format Required Drop Prefix Suffix DFM_EN4 78 Data Format Non Match Error Tone Data Format Non Match Error Tone On DFMDEC0 78 Data Format Non Match Error Tone Off DFMDEC1 78 Primary Alternate Data Formats Primary Data Format ALTFNM0 79 Data Format 1 ALTFNM1 79 Data Format 2 ALTFNM2 79 Data F...

Страница 191: ...ff C39APP0 86 On C39APP1 86 Code 32 Pharmaceutical PARAF Off C39B320 87 On C39B321 87 Code 39 Full ASCII Off C39ASC0 88 On C39ASC1 88 Code 39 Code Page C39DCP 88 Interleaved 2 of 5 Default All Interleaved 2 of 5 Settings I25DFT 88 Off I25ENA0 88 On I25ENA1 88 Interleaved 2 of 5 Check Digit No Check Digit I25CK20 89 Validate But Don t Transmit I25CK21 89 Validate and Transmit I25CK22 89 Interleaved...

Страница 192: ...A0 93 On A25ENA1 93 Straight 2 of 5 IATA Redundancy Range 0 10 0 A25VOT 94 Straight 2 of 5 IATA Message Length Minimum 1 48 4 出1 A25MIN 94 Maximum 1 48 48 A25MAX 94 Matrix 2 of 5 Default All Matrix 2 of 5 Settings X25DFT 94 Off X25ENA0 94 On X25ENA1 94 Matrix 2 of 5 Message Length Minimum 1 80 4 X25MIN 95 Maximum 1 80 80 X25MAX 95 Code 11 Default All Code 11 Settings C11DFT 95 Off C11ENA0 95 On C1...

Страница 193: ...0 60 TELMAX 100 UPC A Default All UPC A Settings UPADFT 100 Off UPBENA0 101 On UPBENA1 101 UPC A Check Digit Off UPACKX0 101 On UPACKX1 101 UPC A Number System Off UPANSX0 101 On UPANSX1 101 UPC A 2 Digit Addenda Off UPAAD20 102 On UPAAD21 102 UPC A 5 Digit Addenda Off UPAAD50 102 On UPAAD51 102 UPC A Addenda Required Not Required UPAARQ0 102 Required UPAARQ1 102 Addenda Timeout Range 0 120 120 DL...

Страница 194: ...tings E13DFT 108 Off E13ENA0 108 On E13ENA1 108 Convert UPC A to EAN 13 UPC A Converted to EAN 13 UPAENA0 108 Do not Convert UPC A UPAENA1 108 EAN JAN 13 Check Digit Off E13CKX0 109 On E13CKX1 109 EAN JAN 13 Addenda 2 Digit Addenda On E13AD21 109 2 Digit Addenda Off E13AD20 109 5 Digit Addenda On E13AD51 109 5 Digit Addenda Off E13AD50 109 EAN JAN 13 Addenda Required Not Required E13ARQ0 109 Requi...

Страница 195: ...git Addenda ARQ9791 114 Addenda Timeout Range 0 120 120 DLYADD 114 EAN JAN 13 Addenda Separator Off E13ADS0 115 On E13ADS1 115 ISBN Translate Off E13ISB0 115 On E13ISB1 115 EAN JAN 8 Default All EAN JAN 8 Settings EA8DFT 115 Off EA8ENA0 116 On EA8ENA1 115 EAN JAN 8 Check Digit Off EA8CKX0 116 On EA8CKX1 116 EAN JAN 8 Addenda 2 Digit Addenda Off EA8AD20 116 2 Digit Addenda On EA8AD21 116 5 Digit Ad...

Страница 196: ...GS1 DataBar Expanded Default All GS1 DataBar Expanded Settings RSEDFT 120 Off RSEENA0 120 On RSEENA1 120 GS1 DataBar Expanded Msg Length Minimum 4 74 4 RSEMIN 121 Maximum 4 74 74 RSEMAX 121 Trioptic Code Off TRIENA0 121 On TRIENA1 121 Codablock A Default All Codablock A Settings CBADFT 121 Off CBAENA0 121 On CBAENA1 121 Codablock A Msg Length Minimum 1 600 1 CBAMIN 122 Maximum 1 600 600 CBAMAX 122...

Страница 197: ...MU2 127 GS1 Code Expansion Off EANEMU3 127 EAN8 to EAN13 Conversion EANEMU4 127 GS1 Emulation Off EANEMU0 127 TCIF Linked Code 39 On T39ENA1 127 Off T39ENA0 127 QR Code Default All QR Code Settings QRCDFT 127 On QRCENA1 128 Off QRCENA0 128 QR Code Msg Length Minimum 1 7089 1 QRCMIN 128 Maximum 1 7089 7089 QRCMAX 128 QR Code Append One Scan QRCAPP1 129 Swipe QRCAPP2 129 Point Shoot QRCAPP3 129 Off ...

Страница 198: ...6 3116 IDMMAX 133 Data Matrix Code Page Data Matrix Code Page 51 IDMDCP 133 MaxiCode Default All MaxiCode Settings MAXDFT 134 On MAXENA1 134 Off MAXENA0 134 MaxiCode Msg Length Minimum 1 150 1 MAXMIN 134 Maximum 1 150 150 MAXMAX 134 Aztec Code Default All Aztec Code Settings AZTDFT 134 On AZTENA1 135 Off AZTENA0 135 Aztec Code Msg Length Minimum 1 3832 1 AZTMIN 135 Maximum 1 3832 3832 AZTMAX 135 A...

Страница 199: ...Barcode On POSTAL17 138 Postal 4i and Postnet with B and B Fields On POSTAL19 139 Planet and Postnet On POSTAL12 139 Planet and Postnet with B and B Fields On POSTAL18 139 Planet and Postal 4i On POSTAL13 139 Planet and Intelligent Mail Barcode On POSTAL15 139 Planet Postnet and Postal 4i On POSTAL21 139 Planet Postnet and Intelligent Mail Barcode On POSTAL22 139 Planet Postal 4i and Intelligent M...

Страница 200: ... On CPCENA1 142 China Post Hong Kong 2 of 5 Msg Length Minimum 2 80 4 CPCMIN 142 Maximum 2 80 80 CPCMAX 142 Korea Post Default All Korea Post Settings KPCDFT 142 Off KPCENA0 142 On KPCENA1 142 Korea Post Msg Length Minimum 2 80 4 KPCMIN 143 Maximum 2 80 48 KPCMAX 143 Korea Post Check Digit Transmit Check Digit KPCCHK1 143 Don t Transmit Check Digit KPCCHK0 143 Imaging Default Commands Image Snap D...

Страница 201: ...MGFMT0 File Format TIFF binary IMGFMT1 File Format TIFF binary group 4 compressed IMGFMT2 File Format TIFF grayscale IMGFMT3 File Format Uncompressed binary IMGFMT4 149 157 File Format Uncompressed grayscale IMGFMT5 File Format BMP IMGFMT8 Histogram Stretch Off IMGHIS0 Histogram Stretch On IMGHIS1 Noise Reduction Off IMGFSP0 Noise Reduction On IMGFSP1 Invert Image around X axis IMGNVX1 Invert Imag...

Страница 202: ...3 Document Image Filter Off IMGUSH0 Document Image Filter On 0 255 IMGUSH Don t Ship Histogram IMGHST0 Ship Histogram IMGHST1 Utilities Add Code I D Prefix to All Symbologies Temporary PRECA2 BK2995C80 159 Show Software Revision Boot version REVINF 159 App version REV_WA 159 Test Menu On TSTMNU1 160 Off TSTMNU0 160 Application Plug Ins Apps Plugin function off PLGFEN0 160 Enable EasyDL2 0 PLGFEN 1...

Страница 203: ...commended by Honeywell for using HH490 corded area imaging scanner System Architecture Connect with USB HH490 scanner can be connected to the USB port of a computer Connect with RS232 Serial Port HH490 scanner can be connected to the appropriate RS232 interface cable to a computer HostComputer USB 10 CHAPTER ...

Страница 204: ...on Steps Ensure virus protection is installed signature files are up to date and subscriptions are active on all machine hosting Honeywell products Allow only digitally signed software from trusted sources to run Use a firewall at the interface between other networks and Honeywell Solution components Unauthorized External Access This threat includes intrusion into the Honeywell system from the bus...

Страница 205: ...eat is most difficult since attackers may have legitimate access to part of the systems and are simply trying to exceed their permitted access Unauthorized internal access can result in Loss of system availability The capture modification or deletion of data and The theft or damage of system contents Mitigation Steps Implement strong password protection on Honeywell Solution components and include...

Страница 206: ...ional Institute of Standards and Technology NIST track CVEs and mark their level of criticalness For example when a critical vulnerability was found in the popular OpenSSL cryptographic software in April of 2014 the TLS heartbeat read overrun CVE 2014 0160 was tracked and marked by both organizations A CVE such as the CVE 2014 0160 must be addressed as soon as possible Honeywell provides system up...

Страница 207: ...ght General Duty Healthcare 4 58 oz 130g 4 76 oz 135g Electrical Voltage Requirements 4 4 to 5 5 VDC at input connector Current Draw Standby 0 5W 100mA 5VDC Operating 2 5W 500mA 5VDC Illumination LED White color 2000 2500k Aiming LED Red LED 624nm Peak Wavelength Environmental Temperature Ranges Operating 32 F to 122 F 0 C to 50 C Storage 40 F to 140 F 40 C to 60 C Humidity 0 to 95 non condensing ...

Страница 208: ... Skew Angle 65 Pitch Angle 60 Motion Tolerance Up to 75 cm s for 13 mil UPC at optimal focus Symbol Contrast 25 or greater Grade A Scan Angle Horizontal 48 Vertical 30 Depth of Field Charts Typical Performance Symbology Near Distance mm Far Distance mm 5 mil Code 39 40 225 6 7mil PDF417 50 210 10mil Data Matrix 45 185 13mil UPC A 35 430 20mil QR Code 20 355 Resolution Code 39 3mil Resolution PDF 4...

Страница 209: ... 190 6 7mil PDF417 65 190 10mil Data Matrix 60 130 13mil UPC A 40 345 20mil QR Code 30 290 Standard Connector Pinouts Note The following pin assignments are not compatible with some Honeywell legacy products Use of a cable with improper pin assignments may lead to damage to the unit Use of any cables not provided by the manufacturer may result in damage not covered by your warranty Serial Output 1...

Страница 210: ...196 HH490 User Guide 1 2 3 4 5 6 7 8 9 10 5V power Data Data Cable shield Supply ground USB 10 Pin Modular Plug ...

Страница 211: ... detergent water solution If a mild detergent solution is used wipe the scanner or base with a clean cloth dampened only with water to remove any detergent residue Note Reading performance may degrade if the scanner s window is not clean If the window is visibly dirty or if the scanner isn t operating well clean the window Caution Do not submerge the scanner in water or cleaning solution Do not us...

Страница 212: ...ts Honeywell Instructions for Cleaning General Purpose Disinfectant Ready Housing Devices Inspect Cords and Connectors Inspect the interface cable and connector for wear or other signs of damage A badly worn cable or damaged connector may interfere with scanner operation Contact your distributor for information about cable replacement Cable replacement instructions are on page 198 Replace Cables i...

Страница 213: ...elease 4 Straighten one end of a paper clip 5 Insert the end of the paper clip into the small hole and press in This depresses the retention tab releasing the connector Pull the connector out while maintaining pressure on the paper clip then remove the paper clip 6 Replace with the new cable Insert the connector into the opening and press firmly The connector is keyed to go in only one way and wil...

Страница 214: ...ratched or exhibiting voids Aren t coated with frost or water droplets on the surface Are enabled in the scanner or in the decoder to which the scanner connects Is the barcode displayed but not entered The barcode is displayed on the host device correctly but you still have to press a key to enter it the Enter Return key or the Tab key for example You need to program a suffix Programming a suffix ...

Страница 215: ...nd Data Format beginning on page 59 for information about using Code ID and AIM ID Linear Symbologies AIM Honeywell Linear Symbology ID Possible modifiers m ID Hex All Symbologies 99 Codabar Fm 0 1 a 61 Code 11 H3 h 68 Code 128 Cm 0 1 2 4 j 6A Code 32 Pharmaceutical PARAF X0 3C Code 39 supports Full ASCII mode Am 0 1 3 4 5 7 b 62 TCIF Linked Code 39 TLC39 L2 T 54 Code 93 and 93i Gm 0 9 A Z a m i 6...

Страница 216: ...X0 m 6D NEC 2 of 5 X0 Y 59 Straight 2 of 5 IATA Rm 0 1 3 f 66 Straight 2 of 5 Industrial S0 f 66 MSI Mm 0 1 g 67 Telepen Bm t 74 UPC 0 1 2 3 8 9 A B C UPC A E0 c 63 UPC A with Add On E3 c 63 UPC A with Extended Coupon Code E3 c 63 UPC E E0 E 45 UPC E with Add On E3 E 45 UPC E1 X0 E 45 Add Honeywell Code ID 5C80 Add AIM Code ID 5C81 Add Backslash 5C5C Batch mode quantity 5 35 2D Symbologies AIM Hon...

Страница 217: ...taBar Omnidirectional em 0 3 y 79 MaxiCode Um 0 3 x 78 PDF417 Lm 0 2 r 72 MicroPDF417 Lm 0 5 R 52 QR Code Qm 0 6 s 73 Micro QR Code Qm s 73 Postal Symbologies AIM Honeywell Postal Symbology ID Possible modifiers m ID Hex All Symbologies 99 Australian Post X0 A 41 British Post X0 B 42 Canadian Post X0 C 43 China Post X0 Q 51 InfoMail X0 2c Intelligent Mail Barcode X0 M 4D Japanese Post X0 J 4A KIX ...

Страница 218: ... Enter CTRL A Select all 2 02 STX Caps Lock CTRL B Bold 3 03 ETX ALT Make CTRL C Copy 4 04 EOT ALT Break CTRL D Bookmark 5 05 ENQ CTRL Make CTRL E Center 6 06 ACK CTRL Break CTRL F Find 7 07 BEL Enter Ret CTRL G 8 08 BS Apple Make CTRL H History 9 09 HT Tab CTRL I Italic 10 0A LF Apple Break CTRL J Justify 11 0B VT Tab CTRL K hyperlink 12 0C FF Delete CTRL L list left align 13 0D CR Enter Ret CTRL...

Страница 219: ... 4F O 111 6F o 48 30 0 80 50 P 112 70 p 49 31 1 81 51 Q 113 71 q 50 32 2 82 52 R 114 72 r 51 33 3 83 53 S 115 73 s 52 34 4 84 54 T 116 74 t 53 35 5 85 55 U 117 75 u 54 36 6 86 56 V 118 76 v 55 37 7 87 57 W 119 77 w 56 38 8 88 58 X 120 78 x 57 39 9 89 59 Y 121 79 y 58 3A 90 5A Z 122 7A z 59 3B 91 5B 123 7B 60 3C 92 5C 124 7C 61 3D 93 5D 125 7D 62 3E 94 5E 126 7E 63 3F 95 5F _ 127 7F Extended ASCII ...

Страница 220: ...e Numeric Keypad 0x4E 157 9D Numeric Keypad 0x4A 158 9E ž Numeric Keypad 0x37 159 9F Ÿ ƒ Caps Lock 0x3A 160 A0 á Num Lock 0x45 161 A1 í Left Alt 0x38 162 A2 ó Left Ctrl 0x1D 163 A3 ú Left Shift 0x2A 164 A4 ñ Right Shift 0x36 165 A5 Ñ Print Screen n a 166 A6 ª Tab 0x0F 167 A7 º Shift Tab 0x8F 168 A8 Enter 0x1C 169 A9 Esc 0x01 170 AA ª Alt Make 0x36 171 AB Alt Break 0xB6 172 AC Control Make 0x1D 173...

Страница 221: ...Ì 205 CD Í 206 CE Î 207 CF Ï 208 D0 Ð 209 D1 Ñ 210 D2 Ò 211 D3 Ó 212 D4 Ô 213 D5 Õ 214 D6 Ö 215 D7 216 D8 Ø 217 D9 Ù 218 DA Ú 219 DB Û 220 DC Ü 221 DD Ý 222 DE Þ 223 DF ß 224 E0 à α 225 E1 á ß 226 E2 â Γ 227 E3 ã π 228 E4 ä Σ 229 E5 å σ 230 E6 æ μ 231 E7 ç τ 232 E8 è Φ 233 E9 é Θ 234 EA ê Ω 235 EB ë δ 236 EC ì 237 ED í φ 238 EE î ε 239 EF ï 240 F0 ð 241 F1 ñ 242 F2 ò 243 F3 ó 244 F4 ô 245 F5 õ 246...

Страница 222: ...try Standard Keyboard Country Honeywell Code Page Option United States standard ASCII ISO IEC 646 IRV n a 1 Automatic National Character Replacement ISO IEC 2022 n a 2 default Binary Code page n a n a 3 Default Automatic National Character replacement will select the below Honeywell Code Page options for Code128 Code 39 and Code 93 United States ISO IEC 646 06 0 1 Canada ISO IEC 646 121 54 95 Cana...

Страница 223: ...ç µ é ù è DE 4 84 Ä Ö Ü ä ö ü ß CH 6 86 ù à é ç ê î ô ä ö ü û SE FI 2 82 É Ä Ö Å Ü é ä ö å ü DK 8 88 Æ Ø Å æ ø å NO 9 94 Æ Ø Å æ ø å IE 73 97 Ó É Í Ú Á ó é í ú á IT 5 85 ç é ù à ò è ì PT 13 92 Ã Ç Õ ã ç õ ES 10 90 Ñ ñ ç ES 51 91 Ñ Ç ñ ç COUNTRY Country Keyboard Honeywell CodePage ISO IEC 646 National Character Replacements Keyboard Key References 104 Key U S Style Keyboard 105 Key European Style K...

Страница 224: ...56 7890 EAN 13 9 780330 290951 Interleaved 2 of 5 01234567890 Code 128 Code 128 Codabar A13579B Code 39 BC321 Code 93 123456 9 Matrix 2 of 5 6543210 Straight 2 of 5 Industrial 123456 RSS 14 01 00123456789012 Code 49 1234567890 PDF417 Car Registration ...

Страница 225: ...HH490 User Guide 211 SAMPLE SYMBOLS CONTINUED Postnet Zip Code Data Matrix Test Symbol QR Code Numbers MaxiCode Test Message Micro PDF417 Test Message DotCode 12345 ...

Страница 226: ...212 HH490 User Guide PROGRAMMING CHART 0 1 2 3 4 5 6 7 8 9 ...

Страница 227: ...uide 213 PROGRAMMING CHART CONTINUED A B C D E F Save Discard Reset Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again ...

Страница 228: ...214 HH490 User Guide Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com HH490 EN UG 01 REV A 02 21 ...

Отзывы: