Output Sequence Example 2 - Three Symbologies with <> Separators
In this example, you are scanning the same three barcodes, but you want <>
brackets and a carriage return and line feed to separate your output.
The sequence editor would use the same command line as shown in
Sequence Example 1 - Three Symbologies
SEQBLK
62
9999
43
FF
6A
9999
54
FF
72
9999
4D
FF
sequence editor start command
code identifier for Code 39
code length that must match for Code 39, 9999 = all lengths
start character match for Code 39, 43h = "C"
termination string for first code
code identifier for Code 128
code length that must match for Code 128, 9999 = all lengths
start character match for Code 128, 54h = “T”
termination string for first code
code identifier for PDF417
code length that must match for PDF417, 9999 = all lengths
start character match for PDF417, 4Dh = “M”
termination string for third code
But you would add your <> separators for each sequence:
SEQSEP99
3C
3E
separator for each sequence, 99 = all symbologies
left bracket (<)
right bracket (>)
And add the carriage return and line feed as a suffix:
SEQSUF99
separator for suffixes, 99 = all symbologies
Содержание HH490
Страница 1: ...HH490 Area Imaging Scanner User Guide ...
Страница 14: ...xiv HH490 User Guide ...
Страница 94: ...80 HH490 User Guide Single Scan Data Format 2 Single Scan Data Format 3 ...
Страница 158: ...144 HH490 User Guide ...
Страница 210: ...196 HH490 User Guide 1 2 3 4 5 6 7 8 9 10 5V power Data Data Cable shield Supply ground USB 10 Pin Modular Plug ...
Страница 226: ...212 HH490 User Guide PROGRAMMING CHART 0 1 2 3 4 5 6 7 8 9 ...
Страница 228: ...214 HH490 User Guide Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com HH490 EN UG 01 REV A 02 21 ...