Intercharacter Delay
An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be
placed between the transmission of each character of scanned data. Scan the
Intercharacter Delay barcode below, then scan the number of 5ms delays from
the
beginning on page 211, then Save.
Intercharacter Delay
To remove this delay, scan the Intercharacter Delay barcode, then set the
number of delays to 0. Scan the Save barcode from the
beginning on page 211.
Note:
Intercharacter delays are not supported in USB serial emulation.
User Specified Intercharacter Delay
An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be
placed after the transmission of a particular character of scanned data. Scan the
Delay Length barcode below, then scan the number of 5ms delays from the
beginning on page 211, then Save.
Next, scan the Character to Trigger Delay barcode, then the 2-digit hex value for
a printable character to trigger the delay (see
205.
)
Delay Length
Character to Trigger Delay
To remove this delay, scan the Delay Length barcode, and set the number of
delays to 0. Scan the Save barcode from the
page 211.
Intercharacter Delay
Prefix
Scanned Data
Suffix
Содержание HH490
Страница 1: ...HH490 Area Imaging Scanner User Guide ...
Страница 14: ...xiv HH490 User Guide ...
Страница 94: ...80 HH490 User Guide Single Scan Data Format 2 Single Scan Data Format 3 ...
Страница 158: ...144 HH490 User Guide ...
Страница 210: ...196 HH490 User Guide 1 2 3 4 5 6 7 8 9 10 5V power Data Data Cable shield Supply ground USB 10 Pin Modular Plug ...
Страница 226: ...212 HH490 User Guide PROGRAMMING CHART 0 1 2 3 4 5 6 7 8 9 ...
Страница 228: ...214 HH490 User Guide Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com HH490 EN UG 01 REV A 02 21 ...