User Manual of Explosion-Proof Bullet Camera
76
Figure 6-39
Time Settings
Configuring Time Synchronization by NTP Server
Steps:
(1)
Check the radio button to enable the
NTP
function.
(2)
Configure the following settings:
Server Address:
IP address of NTP server.
NTP Port:
Port of NTP server.
Interval:
The time interval between the two synchronizing actions by NTP server. It can be
set from 1 to 10080 minutes.
Figure 6-40
Time Sync by NTP Server
You can click
to make sure that the NTP server is connected.
If the camera is connected to a public network, you should use a NTP server that has a time
synchronization function, such as the server at the National Time Center (IP Address:
210.72.145.44). If the camera is set in a customized network, NTP software can be used to
establish a NTP server for time synchronization.
Configuring Time Synchronization Manually
Steps:
(1)
Check the
Manual Time Sync
radio button.
(2)
Click
to set the system time from the pop-up calendar.
(3)
Click