C7660 SELECTABLE TEMPERATURE SENSOR

63-2670EF—01

2

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the 

TRADELINE® Catalog or price sheets for complete ordering number.

If you have additional questions, need further information, or would like to comment on our products or services, please write or 

phone:

1.

Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory).

2.

Honeywell Customer Care

1885 Douglas Drive North

Minneapolis, Minnesota 55422-4386

In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario M1V 4Z9.

International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, 

Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.

SPECIFICATIONS

Model: 

C7660 Selectable Temperature Sensor

Case: 

Duct mount

 

Temperature Sensing Element:  

Thermistor

Output Signal: 

4mA not OK to economize, 20 mA OK to 

economize

 

Operating Ambient Temperature Range: 

-40° to 149° F 

(-40° to 65° C).

Shipping Temperature Range:  

-40° to 149° F (-40° to 

65° C).

Supply Voltage: 

Power to sensor is supplied through 

economizer or if not used with an economizer, logic power 

input is 21.6 vdc ± 1.5 vdc.

Electrical Connections: 

Two 1/4 in. (6.4 mm) quick connect 

terminals.

Approval: 

 Underwriters Laboratories Inc. Flammability 

Rating UL94-5V

Dimensions: 

See Fig. 1 

Hysteresis: 

Hyst/- 1F; Economizer Cut-in 1F below 

setpoint, Cut-out 1F above setpoint

Accuracy: 

± 1° F

Fig. 1. C7660 Selectable Temperature Sensor Dimensions 

in in. (mm).

INSTALLATION

When installing this Product...

1.

Read these instructions carefully. Failure to follow them 

could damage the product or cause a hazardous 

condition. 

2.

Check the ratings given in the instructions and on the 

product to make sure the product is suitable for your 

application.

3.

Installer must be a trained experienced service 

technician.

4.

After installation is complete, check out product 

operation as provided in these instructions.

5.

Verify dip switch settings match desired changeover 

outside air temperature.

6.

Verify polarity of wiring connections from sensor to 

controller is correct.

M27634

+

9/16

(14)

3-7/8 (96)

5/16 (8)

3-5/32 

(80)

2-3/4 

 (70)

1 (25)

7/32

(6)

ON OFF

1     2    3

Содержание C7660

Страница 1: ...ses temperature of outdoor air and provides a signal to economizer control with OK or not OK to economize Selectable dip switch provides 8 change over temperature options When temperature of outdoor air is below change over temperature the outdoor air damper is opened to reduce the cooling load in the building Provides 4 OR 20 mA output signal to economizer control At 4 mA not OK to economize 20 m...

Страница 2: ...ze Operating Ambient Temperature Range 40 to 149 F 40 to 65 C Shipping Temperature Range 40 to 149 F 40 to 65 C Supply Voltage Power to sensor is supplied through economizer or if not used with an economizer logic power input is 21 6 vdc 1 5 vdc Electrical Connections Two 1 4 in 6 4 mm quick connect terminals Approval Underwriters Laboratories Inc Flammability Rating UL94 5V Dimensions See Fig 1 H...

Страница 3: ...below the change over setpoint the sensor will provide a 20 mA signal to the economizer with translate to OK to economize positioning the damper open on a call for cooling When the outdoor air is above the change over setpoint the sensor provides a 4 mA signal to the economizer which translates to not OK to economize and the outdoor damper drives to minimum position The C7660 temperature sensors r...

Страница 4: ...rated operation requires a two stage cooling thermostat The integrated control will provide the most energy savings For exclusive operation the changeover set point needs to allow mechanical cooling when the economizer can no longer meet the cooling load requirement The 63 degree F setting is the most typical changeover set point for this type of control but is dependent on the building and climat...

Страница 5: ...nal à l économiseur lui indiquant s il convient ou non de passer en mode économiseur Commutateurs DIP offrant 8 choix de températures d inversion Quand la température de l air extérieur est inférieure à la température d inversion le registre d admission d air frais est ouvert afin de réduire la charge de refroidissement du bâtiment Transmet un signal de 4 OU 20 mA à l économiseur à 4 mA le système...

Страница 6: ...à 149 F Température à l expédition 40 à 65 C 40 à 149 F Tension d alimentation Le capteur est alimenté en courant par l économiseur ou s il n est pas employé avec un économiseur l alimentation logique sera de 21 6 V c c 1 5 V c c Raccordement électrique Deux bornes à connexion rapide de 6 4 mm 1 4 po Approbation Laboratoire des assureurs Inc Indice d inflammabilité UL9 5V Encombrement Voir la Fig ...

Страница 7: ...met à l économiseur un signal de 20 mA que celui ci traduit comme une commande de mise en service de l économiseur il positionne alors le registre à la position d ouverture lors d une demande de refroidissement Quand le capteur extérieur détecte une température supérieure au point de consigne le capteur transmet un signal de 4 mA à l économiseur que celui ci interprète comme une commande de ne pas...

Страница 8: ...d inversion doit permettre le refroidissement mécanique lorsque l économiseur ne suffit plus à répondre à la charge de refroidissement Le réglage de 63 F est le point d inversion le plus fréquent pour ce type de régulation le réglage dépend toutefois du bâtiment et du climat Pour un fonctionnement intégré le point de consigne d inversion doit être réglé au point de consigne de refroidissement type...

Отзывы: