GasAlertMicro
User Options Menu
To enable/disable the safe display option, complete the
following:
1. From the user options menu, use
G
or
H
to scroll
to the
SAFE dISPLAY
option.
2. Press
C
to select this option.
The LCD displays the current mode (
On
or
OFF
)
and then returns to the
FiniSh OPtionS
screen.
or
3. Use
G
or
H
to scroll to a new user option, or press
C
to exit user options and return to normal
operating mode.
Combustible Sensor Measuring Selection
The
LEL SEn unitS
option is used to select how the
measurements are displayed. The options are 0-100% LEL
or 0-5.0% vol.
Note
The detector is shipped with the combustible
sensor set to measure and display combustible
gases in the 0-100% LEL (lower explosive limit)
range.
The detector can be set to measure and display methane in
the 0-5.0% by volume range.
Note
Percent by volume measurements apply to
methane only.