S E C T I O N 3
Programming the GSMHS
General Information
The GSMHS is designed to deliver alarms via the GSM network to an AlarmNet central
station when it is registered with a valid AlarmNet account.
The GSMHS module requires an AlarmNet–i account. For new installations, please obtain the
account information from the central station prior to programming this module. For replacement
installations, the AlarmNet-i account is created automatically when the module is registered (based
on the existing account).
You can program a GSMHS by one of the following methods:
Through the AlarmNet Direct website
Through use of a 7720P Programming Tool
Through a programming mode in the control panel on panels that support this option
(e.g., VISTA-128BP and FBP)
UL
Only ECP and Zone Trigger modes have been evaluated by UL.
Programming the Control Panel to work with the GSMHS
For Residential and Commercial control panels, there are certain programming field settings
that must be adhered to for using the GSMHS. (For programming information, please refer
to the appropriate control panel guides.) Ensure the following programming fields are set as
follows:
RESIDENTIAL / COMMERCIAL Control Panels (Such as the VISTA-10P, 15P, and 20P series.)
Programming Field
Setting
29 Menu Mode for IP/GSM Enable
1 (Enable LRR.)
54 Dynamic Signaling Delay
0 (Dialer and LRR reports go out at the same time.)
55 Dynamic Signaling Priority
0 (Primary dialer reports first.)
COMMERCIAL Control Panels (Such as the VISTA-128/250 series.)
Programming Field
Setting
56 Dynamic Signaling Delay
00 (Dialer and LRR reports go out at the same time.)
57 Dynamic Signaling Priority
1 (Communicator, as first reporting.)
58 Comm Central Station #1
Category Enable
111111 (All events will be reported to the primary Central
Station.)
59 Comm Central Station #2
Category Enable
000000 (If Central Station #2 is not used.)
111111 (If Central Station #2 is used.)
#93 Menu Mode
Zone programming – set Zone 803 for Type 05.
Device programming – set Address 03 for Type 06 (LRR).
Содержание AlarmNet GSMHS
Страница 2: ......
Страница 8: ...GSMHS Installation and Setup Guide 1 4 ...
Страница 32: ...GSMHS Installation and Setup Guide 3 18 ...
Страница 36: ...GSMHS Installation and Setup Guide 4 4 ...
Страница 46: ...GSMHS Installation and Setup Guide B 2 ...
Страница 48: ...GSMHS Installation and Setup Guide C 2 ...
Страница 50: ...GSMHS Installation and Setup Guide D 2 ...
Страница 51: ...NOTES ...
Страница 52: ...NOTES ...
Страница 53: ...NOTES ...