GSMHS Installation and Setup Guide
2-2
7845GSM-015-V0
MOUNTING
SCREW (4)
(TYP)
WALL OR
MOUNTING
SURFACE
INTERNAL
ANTENNA
TAB
COVER SECURING SCREW
OPTIONAL WIRING
KNOCKOUT
OPTIONAL WIRING
KNOCKOUTS
TAB
CASE
FRONT
CASE
BACK
FOR
EXTERNAL
ANTENNA
50 OHM,
MMCX
ONLY
7720P
PROGRAMMER
PORT
NOT
FOR
TELEPHONE
SERVICE
USE!
PRIMARY
POWER
: 9 -
16 .5
VAC
BATTERY:
6V.
3.1 AHr
FOR
24 Hr
BACKUP
FCC
ID: GIPMC56IC:
Y26
7W
- MC56
GSM
GPPS
WEB
MODE 2
MODE 1
RSSI
Honeywell
RX
TX
MAC
LABEL
HERE
TRANSMIT
LED
Figure 2-1. Mounting the GSMHS
Wiring the GSMHS
UL
Installation must be in accordance with the National Electrical code and UL681, Installation and
Classification for Burglar and Hold-Up Alarm Systems.
GSMHS must be connected to a UL Listed dry contact or voltage trigger outputs of a UL Listed
compatible control unit.
All interconnecting wires between the UL Listed control and the GSMHS must be less than 3 feet in
length contained in the same room. All interconnecting wiring must be installed in rigid or EMT (where
exposed on interior walls) or in flexible metal tubing if run in the walls or ceiling.
A UL listed control must monitor the radio fault output of the GSMHS. An Ademco No. 659EN or other
UL listed Telco Line Fault Monitor’s output must be connected to an input zone on the control panel or
an input zone on the GSMHS if used in zone trigger mode. Premises openings and closings should
be sent via the UL listed control.
Only ECP and Zone Trigger modes have been evaluated by UL.
Wiring a Telco Line Fault Monitor for Zone Mode
When using an Ademco No. 659EN Line Fault Monitor, follow the diagram below for wiring
information. (For detailed information, refer to the Ademco No. 659EN Installation
Instructions P3516-1V2.)
GSMHS High Security
Communicator
CONTROL PANEL
GSMHS-003-V0
ZONE 7
OR
RED
AUX
POWER
9
4
10
TB1
ZONE 6
GND
RED
No. 659EN Line Fault Monitor
8
6
7
5
3
4
2
1
6-14VDC
STAND BY: 5mA
ACTIVE: 35mA
BLK
BLK
TO TELCO LINE
(Disregard Polarity)
Содержание AlarmNet GSMHS
Страница 2: ......
Страница 8: ...GSMHS Installation and Setup Guide 1 4 ...
Страница 32: ...GSMHS Installation and Setup Guide 3 18 ...
Страница 36: ...GSMHS Installation and Setup Guide 4 4 ...
Страница 46: ...GSMHS Installation and Setup Guide B 2 ...
Страница 48: ...GSMHS Installation and Setup Guide C 2 ...
Страница 50: ...GSMHS Installation and Setup Guide D 2 ...
Страница 51: ...NOTES ...
Страница 52: ...NOTES ...
Страница 53: ...NOTES ...