3-15
PROMPTS ZONE
TRIG.
4204/
2-4204
ENTRY OPTIONS
DESCRIPTION
47
Restore Zn5 Y/N
(Y)_
✔
2-
4204
only
[Y], [N]
Enables restore reporting for zone 5.
48
Delay Zn5 (secs)
(00)_
✔
2-
4204
only
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 5.
49
Rpt Zn5 ONLY if
Armed (N)_
✔
2-
4204
only
[Y], [N]
Reports alarms on zone 5 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 5.
50
Enable Zn6 Y/N
(N)_
4204
only
[Y], [N]
Enables alarm reporting for zone 6.
If [N], skip to Prompt 56: "Enable Zn7."
51
Zn6 Trigger Type
(V+)_
✔
4204
only
•
(EOLR)
•
(V+)
•
(V–)
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
52
Invert Zn6 Y/N
(N)_
✔
4204
only
[Y], [N]
Inverts the alarm and normal states of the zone
6 trigger; otherwise uses normal input signal.
53
Restore Zn6 Y/N
(Y)_
✔
✔
[Y], [N]
Enables restore reporting for zone 6.
54
Delay Zn6 (secs)
(00)_
✔
✔
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 6.
55
Rpt Zn6 ONLY if
Armed (N)_
✔
✔
[Y], [N]
Reports alarms on zone 6 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 6.
56
Enable Zn7 Y/N
(N)_
4204
only
[Y], [N]
Enables alarm reporting for zone 7, if used.
If [N], skip to Prompt 64: "Review."
57
Zn7 Trigger Type
(V+)_
✔
4204
only
•
(EOLR)
•
(V+)
•
(V–)
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
58
Invert Zn7 Y/N
(N)_
✔
4204
only
[Y], [N]
Inverts the alarm and normal states of the zone
7 trigger; otherwise uses normal input signal.
59
Restore Zn7 Y/N
(Y)_
✔
✔
[Y], [N]
Enables restore reporting for zone 7.
Zone Trigger mode:
This question will only be
displayed if zone 7 is not used as the conditional
(arming) trigger zone.
60
Delay Zn7 (secs)
(00)_
✔
✔
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 7.
Zone Trigger mode:
This question will only be
displayed if zone 7 is not used as the conditional
(arming) trigger zone.
61
Rpt Zn7 ONLY if
Armed (N)_
✔
[Y], [N]
Reports alarms on zone 7 ONLY if the
conditional zone (zone 4 in 4204 mode; zone 8 in
2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 7.
2-4204 mode:
If any zone is programmed to
"Report Only if Armed," or if tamper is enabled,
skip to "Review."