Section 2: Mounting and Wiring
2-3
7845GSM
LYNX
SUPER HIGH
CAPACITY
BATTERY
(OPTIONAL)
REQUIRED FOR
24-HR BACKUP
7845GSM-028-V0
GND
Z3 OR DATA OUT
Z1/Z2 OR DATA IN
ECP (+) VOLTAGE INPUT
RED
BLK
GRN
YEL
RED
BLK
GRN
YEL
4
5
6
3
5
4
4-WIRE CABLE (N4632-4)
1
2
TB1
DO NOT CONNECT THE 7845GSM BACKUP BATTERY
OR TRANSFORMER
WHEN USING WITH LYNXR-I
LRR/IP COMMUNICATIONS PORT
NOTE
LYNXR-I CONTROL PANEL
NC
+12 VDC
GND
D
ATA
I
N
D
A
T
A
OUT
LYNX
STANDARD
CAPACITY
BATTERY
Figure 3. Wiring a LynxR-I for ECP Mode
Wiring for Zone Trigger Mode
To trip a zone on the 7845GSM in V+ trigger mode, the positive triggering voltage from the
control panel must be within 2.0V-14.5V.
Trigger levels above this range may cause permanent damage to the unit.
Trigger levels below this range result in unreliable operation.
To trip a zone on the 7845GSM in V- trigger mode, the negative triggering voltage must be
less than 1.0V.
NOTE:
LynxR and LynxR-EN have a designated trigger for V+ trigger.
Connect a wire from the triggering source (bell output, voltage trigger, etc.) of the control
panel to the zone input of the module, and connect a common ground between the module
and control panel.
UL
The configurations shown in Figures 4 and 5 have not been evaluated by UL.
Examples of zone connections follow:
7845GSM
CONTROL PANEL
7845GSM-012-V0
GND
+12 V AUX
( )
(+)
GND
ZONE INPUT Z1/Z2
ECP (+) VOLTAGE INPUT
2
1
4
5
3
TB1
TRANSFORMER
AC INPUT 2
AC INPUT 1
BELL ( )
BELL (+)
J1
BATTERY
K14139
Figure 4. Wiring the 7845GSM Zone 1 Input for a Positive (+) Triggered Bell Output