Installation Instructions
5-18
Programming Installer and User Schedules
The system provides up to 32 schedules, which can be used to control 11 types of system events at pre-
defined times. 24 schedules are intended for use by the end-user, and 8 are reserved for the installer.
In addition, some events are also reserved for the installer only (listed in the “Enter Event” prompt
paragraph below).
Start Scheduling mode by entering installer code + [#] + [6] [4] while in normal operating mode.
NOTE:
The master code can only access schedules 01-24 and events 00-08.
The following prompts are displayed:
PROMPT
VALID ENTRIES
EXPLANATION
E N T E R S C H E D N O .
0 0 = Q U I T 0 0
Schedule Number
01-24 = end-user schedules
25-32 = installer-only schedules
[
∗
] to continue
Enter the desired schedule number.
E N T E R E V E N T
NOTE:
Events 07 and 10
cause the keypad to
beep every 30 seconds
when messages are
displayed. Stop the
beeps by user code +
OFF.
Enter Event
00 = clear event
01 = Relay On/Off
02 = User Access
03 = Child Not Home Report to
Pager
04 = Forced Stay Arming
†
05 = Forced Away Arming
†
06 = Auto Disarm
07 = Display “Reminder”
08 = Disarm Time Window
10 = Display Custom Words
††
11 = Periodic Test Report
[
∗
] to continue
Enter the desired event number for event you want to occur at a
specified time.
Events 10-11 are reserved for the installer only.
Child-Not-Home report (option 03) is sent to all pagers in the user’s
partition (message sent is 777-7777). User must be enabled for paging
(see User Attributes in
System Operation
section).
Disarm Time Window (08): System can be disarmed only during this
time period. Exception: If a burglary alarm occurs, the system can be
disarmed outside the scheduled time window.
† Forced bypass is automatically enabled regardless of setting in field
*23.
†† if selected, system displays custom words 8, 9, and 10 at defined
time. Can be used as installer’s reminder message to the end user.
D E V I C E N U M B E R
X X
Device Number
01-18 = device number
[
∗
] to continue
This prompt appears if event “1” (relay on/off) was selected, otherwise
it is skipped.
Enter the physical device number as programmed in
∗
79 Menu Mode,
then press [*] to continue to the “Start” prompt.
Device numbers 17 and 18 designate built-in triggers 1 and 2
respectively.
G R O U P N U M B E R
X
Group Number
1-8 = group number
[
∗
] to continue
This prompt appears if event “2” (user access) was selected. Otherwise
it is skipped.
Press [*] to continue to the “Start” prompt.
P A R T I T I O N
X
Partition
0 = all partitions
1 = partition 1
2 = partition 2
3 = partition 3
[
∗
] to continue
This prompt appears if events “3-7,10” were selected. Otherwise it is
skipped.
Press [*] to continue to the “Start” prompt.