60
Configuring the ACUIX ES
Configuring Mimic Tours
Table 3-3
Mimic Tour Functions
Task/Action with Default
Notes
Programming a Mimic Tour
1.
Select the applicable preset number or use the
function programming menu:
•
83
>
Preset
to create mimic tour 1.
•
84
>
Preset
to create mimic tour 2.
•
85
>
Preset
to create mimic tour 3.
2.
During the 120 second countdown, pan and tilt
the dome and adjust the lens zoom setting as
required.
3.
To end the programming mode, either wait for the
countdown to reach 0 or press
86
>
Preset
.
The dome stores the commands in the order performed
during the 120 seconds (two minutes).
Up to three mimic tours can be programmed.
Running a Mimic Tour
1.
Program a mimic tour.
2.
Select the applicable preset number or use the
function programming menu:
•
80
>
Preset
to run mimic tour 1.
•
81
>
Preset
to run mimic tour 2.
•
82
>
Preset
to run mimic tour 3.
Stopping a Mimic Tour
•
Stop any mimic tour by manually controlling the
dome or by sending the dome to a preset, preset
tour, or another mimic tour command.
Deleting a Mimic Tour from the Function Programming Menu
1.
Select
6 Function Programming
>
7 Delete
PS/PT/MT/Sectors.
2.
Locate and select the applicable mimic tour (MT).
The message
Delete Success
displays or if the
selected function and number is not programmed,
the message
Does Not Exist
displays instead.
Existing programming does not have to be deleted to
be reprogrammed. You can edit the coordinates for an
existing mimic tour by following the applicable
programming procedures.
Содержание ACUIX ES
Страница 1: ...Document 800 01949 Rev D 05 09 Installation and Configuration Guide ACUIX ES PTZ Analog Dome ...
Страница 10: ...10 ...
Страница 12: ...12 ...
Страница 26: ...26 Introduction to the ACUIX ES PTZ Dome ...
Страница 46: ...46 Installing the ACUIX ES ...
Страница 70: ...70 Configuring the ACUIX ES ...
Страница 78: ...78 System Administration and Settings ...