ACUIX
TM
ES Installation and Configuration Guide
Document 800-01949 Rev D
35
05/09
Setting the RS485 Control Data Termination (SW5)
1.
Locate SW5. See
.
2.
If required, change from the default and carefully place the SW5 switch in the required
termination position:
•
(Default)
Not terminated: Switch
OFF
(away from ON)
.
•
Terminated in 120 Ohm: Switch
ON
.
Setting the Dome Address (SW4)
Note
Each dome requires a unique address. The ACUIX ES can be addressed from
001 to 255. The default address is 001.
1.
Locate SW4. See
.
•
Carefully place the SW4 switch in the required ON/OFF positions based on the
dome address. See
for a partial list of the address settings and
for a DIP switch example.
Table 2-4
DIP Switch Protocol Settings (SW3 1 - 5)
Protocol Name
Switch Positions
1
2
3
4
5
IntelliBus
OFF
OFF
OFF
OFF
OFF
MAXPRO-mode
OFF
ON
OFF
OFF
OFF
VCL - RS485
ON
ON
OFF
OFF
OFF
VCL UTC
OFF
OFF
ON
OFF
OFF
Pelco P
ON
OFF
ON
OFF
OFF
Pelco D
OFF
ON
ON
OFF
OFF
Diamond
ON
OFF
OFF
OFF
OFF