9. Appendix
9.3. GM Function Block Conversion Program
R200
2MLF-HO2A, 2MLF-HD2A High Speed Counter Module User's Guide
213
May 2010
Honeywell
9.3 GM Function Block Conversion Program
Preset value setting Function Block of GN (HSCC-PRE)
Preset value setting Function Block sets count start value of HSC module. To change
Count, execute Enable Preset after Preset value setting Function Block acts.
Function Block
type
Classifi
cation
Variabl
e name
Type
Contents
Input
REQ
BOOL
FB execution
Executed when changing “0->1”
: Rising edge)
BASE
USINT
Base Number
Base number where HSC
module is equipped
SLOT
USINT
Slot Number
Slot number where HSC module
is equipped
CH
BOOL
Chann
el
Ch0
0
Ch1
1
PSET
_VAL
DINT
Preset range
-2,147,483,648 ~ 2,147,483,647
Output
DONE
BOOL
Execution status
If it completes, it outputs 1 and
holds. If error occurs, it outputs 0
STAT
USINT
Error status
In case of error, outputs error
code
Preset value setting FB of 2MLI/2MLR
Function Block
type
Classifi
cation
Variabl
e name
Type
Contents
Input
REQ
BOOL
FB execution
Executed when changing “0->1” ( :
Rising edge)
BASE
USINT
Base Number
Base number where HSC module is
equipped
SLOT
USINT
Slot Number
Slot number where HSC module is
equipped
MADD
USINT
Chann
Ch0
_F01_CH0_PRESE
02
Содержание 2MLF-HD2A
Страница 18: ...Contents Figures xviii 2MLF HO2A 2MLF HD2A High Speed Counter Module User s Guide R200 Honeywell May 2010 ...
Страница 121: ...7 Programming 7 4 Basic Program R200 2MLF HO2A 2MLF HD2A High Speed Counter Module User s Guide 121 May 2010 Honeywell ...
Страница 178: ...7 Programming 7 6 Program 178 2MLF HO2A 2MLF HD2A High Speed Counter Module User s Guide R200 Honeywell May 2010 ...
Страница 222: ...Honeywell Process Solutions 1860 W Rose Garden Lane Phoenix AZ 85027 USA ...