TROUBLESHOOTING
4-5
7
2
3
4
10
W
R
B u
From page 4-4
Normal
Normal
Normal
Abnormal
Abnormal
Remove all loads from the generator. Verify that
the cooling air duct is not blocked and that the
generator is not placed near a wall.
Remove obstruction.
Check the harness connecting the receptacles
and inverter unit for open or short circuit and for
proper connection.
Replace or repair the control wire harness
(page 8-13).
Abnormal
Replace or repair the generator wire harness
(page 8-10).
Abnormal
Abnormal
Replace the stator (page 8-10).
Check the harness connecting the inverter unit
and generator for open or short and for proper
connection.
Check the generator (page 8-29).
Replace the inverter unit (page 8-7).
Normal
Check the inverter unit (page 8-27).
Normal
Turn the ignition switch OFF and then restart the
engine. If the same symptom continues, replace
the inverter unit (page 8-7).
Viewed from terminal side
GENERATOR WIRE HARNESS
Содержание EU3000i Handi
Страница 37: ...MEMO ...
Страница 73: ...MEMO ...
Страница 75: ...FUEL SYSTEM 6 2 FUEL SYSTEM TOOLS Float level gauge 07401 0010000 ...
Страница 97: ...MEMO ...
Страница 105: ...GENERATOR CHARGING SYSTEM 8 2 GENERATOR CHARGING SYSTEM TOOLS Flywheel puller set 07935 8050004 ...
Страница 133: ...MEMO ...
Страница 149: ...MEMO ...
Страница 150: ...12 1 12 12 MUFFLER MUFFLER REMOVAL INSTALLATION 12 2 ...
Страница 179: ...MEMO ...
Страница 180: ...16 1 16 16 TECHNICAL FEATURES FRAME MADE OF MAGNESIUM 16 2 INDICATOR 16 3 ...
Страница 185: ...MEMO ...
Страница 186: ...17 1 17 17 WIRING DIAGRAMS HOW TO READ A WIRING DIAGRAM RELATED INFORMATION 17 2 WIRING DIAGRAMS 17 4 ...
Страница 193: ...MEMO ...