58
Start-up
6.3
Installation
To install the floor heating controller, please proceed as
follows:
• Open the cover
(E)
by pulling it down
(see fig. 8)
.
• Connect the Homematic IP wired bus to the bus
connecting terminals
(G)
(see
figure 9
). To con-
nect and loosen the single wires, press the or-
ange clamp using a small screwdriver.
• Connect the connection cables of your valve
drives of the heating circuits to the connecting
sockets
(H)
(
see figure 9
).
• Connect (optionally) the connection cable of
your expansion box to the connection socket
(I)
.
• Close the cover again by placing the cover in the
provided guidance rails and sliding the cover up-
wards.
6.4
Behaviour after switching on the power
supply
When the power supply is switched on, the dis-
play
(B)
is permanently on.
If the device has not yet been connected, teach-in mode
will be activated during the first 3 minutes after the power
supply has been switched on. You will find further infor-
mation about connecting your device in the next section.
All connected valve drives are fully opened one after the
other. The valve drives then perform an adaptation run
Содержание HmIPW-FALMOT-C12