52
Function and device overview
Cable bushings
(
see fig. 2
):
(J)
Cable bushing for bus connection
(K)
Cable bushing for bus connection
(L)
Cable bushing for extensional box
(M)
Cable bushing for motorised valve drives
Different to conventional thermal valve drives,
the motorised valve drive can move to any valve
position calculated by the floor heating controller
to achieve the desired room temperature. This
provides a constant heat flow and continuous
heat emission. When switching from convention-
al to motorised valve actuators, it is possible in
rare cases that flow noises may occur at the heat-
ing circuit manifold when the pump pressure is
set high and the valve openings are small. You
can fix this by changing the pump settings or by
adjusting the parameters of the floor heating
controller.
Содержание HmIPW-FALMOT-C12
Страница 3: ...1 I G 1 2 3 4 5 6 7 8 9 10 11 12 H F C B A D E B ...
Страница 4: ...120 mm 2x 2x 2 3 J K L M ...
Страница 5: ...5 5 mm 2x 4 5 ...
Страница 6: ...6 7 ...
Страница 7: ...8 9 B A BUS ...
Страница 8: ...10 11 Channeltaste drücken Selecttaste drücken press channel button press select button ...