10. Fault Finding Chart 

Before maintenance or repair disconnect the pump 

from the power supply to avoid accidental starting of the 
pump! 
 

Fault Cause Remedy 

Motor does not start. 
Fuses blow or motor 
starter trips out immedi-
ately. Caution: Do not 
start again! 

 Supply failure; short-

circuit; earth-leakage; 
fault in cable or motor 
winding 

 Have the cable and 

motor checked and 
repaired by a quali-
fied electrician 

 

 Fuses blow due to use 

of wrong type of fuse 

 Install fuses of the 

correct type 

 

 Impeller blocked by 

impurities 

 Clean the impeller  

 

 Level switch out of 

adjustment or defec-
tive 

 Check the level 

switch 

Pump operates, but 
motor starter trips out 
after a short while

 

 Low setting of thermal 

relay in motor starter 

 Set the relay in ac-

cordance with the 
specifications on the 
pump label 

 

 Increased current con-

sumption due to large 
voltage drop 

 Measure the voltage 

between two motor 
phases. Tolerance: 
± 10% 

 

 Impeller blocked by 

impurities. Increased 
current consumption in 
all three phases 

 Clean the impeller 

Pump operates at be-
low-standard  

 Impeller blocked by 

impurities 

 Clean the impeller 

performance and power 
consumption 

 Wrong direction of 

rotation (only 3 Ph-
pumps) 

 Check the direction 

of rotation and pos-
sibly interchange 
two phases (see 
section 6.4) 

Oil in the medium 

 Wear-out of the radial 

shaft ring 

 Replace the radial 

shaft ring, change 
the oil 

Pump operates, but 
gives no liquid 

 Discharge valve 

closed or blocked 

 Check the discharge 

valve and possibly 
open and/or clean 

 

 Non-return valve 

blocked 

 Clean non-return 

valve 

 

 Air in pump 

 Vent the pump 

 

 
 
 

 
We grant for the described product in the warranty receipt a war-
ranty of declared duration in the warranty receipt. The warranty 
starts with the first start up, latest with the day of sale. A warranty 
claim can be raised only by presentation of the fill in warranty 
receipt together with the purchase receipt. 
Our warranty extends only the removal of material defects or 
production defects. Costs for removal and installation of the 
complained product at the installation place, costs for the ride of 
the mechanicians to the location and from the installation place 
as well as costs for transport are not components of our war-
ranty. Complains caused by installation faults or operating faults, 
unsuitable operation conditions, deficient care or improper efforts 
of repair are out of the question of warranty as well as normal 
wear. Hereby arised costs, especially costs for checking and 
transport are bearing by the sender or operator of the pump. This 
is also valid for an asserted warranty claim if a check results that 
the unit works faultless and is free of defects. All products have a 
high quality standard. Each product is defeated by a streng tech-
nical end control before delivery. If the unit still gives an occasion 
for a legitimated complain, you have the claim of an appropriated 
correction free of charge. Warranty repairs only must lead from 
the manufacturer or an authorized agency. Trials of repair by the 
customer or non-authorized persons during the warranty, causes 
an extinguishing of the warranty. A warranty repair achieved by 
us does not extend the warranty period. Replaced spare parts 
give no reasons for a new  warranty period. Extensive claims are 
excluderd, especially such as diminution, change or compensa-
tion also for any kind of follow up damages. 
 
To guarantee a quick transaction of a warranty claim, please re-
turn the product together with the warranty receipt, purchase re-
ceipt and declaration of defect carriage paid to the manufacturer 
(for the adress see warranty receipt). 
 
Claims caused by damages of transport could be only accepted, 
if the damage is established or confirmed by delivery in the pres-
ence of the forwarder, parcel service, train or post. 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

Pump type 

 

 

 

 

 

 
No.  

 

 

 

 

 

 
Correspond to our warranty conditions 
we achieve 
 
 

 

12 months of warranty 

 
 
 
 
 
 
 
 

Warranty Conditions

 

 

HOMA Pumpenfabrik GmbH 
Industriestraße 1 
D-53819 Nk.-Seelscheid 
Telefon:  + 49 (0) - 22 47 - 70 20 
Telefax:  + 49 (0) - 22 47 - 7 02 44 
Train station: D-53819 Nk.-Seelscheid 

Warranty receipt

 

Содержание TCM 6 Series

Страница 1: ...Montage und Bedienungsanleitung Installation and Operation Instruction Manual 01 2005 Baureihe Series TCV TCM...

Страница 2: ...2 Inhalt Contents Seite 3 Page 9 Seite 15 Page 15 DEUTSCH ENGLISH Bauma e Dimensions...

Страница 3: ...die Pumpentypen TCV TCM aufgrund Ihrer Konzipierung und Bauart sowie in der von uns in Verkehr gebrachten Ausf hrung den einschl gigen grundlegenden Sicherheits und Gesundheitsanforderun gen der EG Ma...

Страница 4: ...eise und Vorschriften aus dieser Bedienungsanleitung nicht eingehalten werden nicht haften F r Zubeh rteile gelten die gleichen Be stimmungen 3 Einsatz und Technische Beschreibung 3 1 Einsatz der Pump...

Страница 5: ...icklungen im Stern geschaltet f r eine Netzspannung von 400 V 3Ph Die Kabelenden U V W ber den Motorschutzschalter mit den Netzanschlussklemmen L1 L2 L3 zu verbinden 6 3 Temperaturf hler Die 1 Ph Moto...

Страница 6: ...tandsdifferenz zwi schen Ein und Ausschaltpunkt l sst sich individuell be stimmen F r eine einwandfreie Funktion beachten Sie bitte die nachstehenden Hinweise Die Befestigungspunkte sowie die L nge de...

Страница 7: ...zu entsorgen lf ll mengen siehe Tabelle auf Seite Wartungsvertrag Zur regelm igen fachm nnischen Durchf hrung aller notwendigen Wartungs und Kontrollarbeiten empfehlen wir den Abschluss eines Wartungs...

Страница 8: ...d erfragen Sie bitte bei unserem 0 22 47 70 20 Kundendienst unter der Hotline f r Notf lle Telefonnummer 0 22 47 70 20 0 22 47 70 23 31 Auf das im beiliegenden Garantieschein beschriebene Produkt gew...

Страница 9: ...bH Industriestrasse 1 D 53819 Neunkirchen Seelscheid hereby declare that in respect to their design and construction the following pump types in the form in which they are marketed by us conform to th...

Страница 10: ...s used for cleaning or maintenance of swimming pools make sure that no persons stay in the swimming pool during operation of the pump and that the pump is reliable by a 30 mA earth leakage circuit bre...

Страница 11: ...the direction of rotation is not cor rect With smaller pumps the direction of rotation may be checked by watching the start jek Put the pump vertical on the ground and lift one edge Start the motor V...

Страница 12: ...ol box to the required mode of operation 9 Maintenance and Repair In case of a defect of the pump a repair shall be car ried out only by the manufacturer or through an author ized workshop Modificatio...

Страница 13: ...terial defects or production defects Costs for removal and installation of the complained product at the installation place costs for the ride of the mechanicians to the location and from the installa...

Страница 14: ...ichnung des Ersatzteiles 1 2 3 4 Ben tigte Menge 1 2 3 4 Lieferanschrift Unterschrift Firmenstempel 13 Order Sheet for Spare Parts To HOMA Pumpenfabrik GmbH D 53819 Neunkirchen Seelscheid Fax 49 22 47...

Страница 15: ...in mm Typ type A B D E F G TCV 4 TCV 5 R 2 AG BSP 2 M 180 221 95 370 180 TCV 6 TCM 6 R 2 AG BSP 2 M 220 260 125 440 210 Schachtinstallation mit Kupplungssystem Submerged Installation with auto couplin...

Страница 16: ...16...

Отзывы: