ASSEMBLY
HOLZMANN Maschinen Austria www.holzmann-maschinen.at
Seite 35
Formatkreissäge / panel saw TS 315F-1500
4.2.9
Connnection of dust extraction system
The 60mm hose is attached to the hood. The Y-connection at the
bottom of the side of the tube is attached.
The suction connection can be connected to a suction system.
4.2.10
Electrical connection
Only a qualified electrician is authorized for the electrical connection, including the installation of
the supply part. This must be cut off before the electrical connection. Only when the main power
supply is cut off, each contact can be closed.
4.2.11
Control
After connection to the power grid, it is necessary to check the direction of the saw blade. To do
this, start the engine briefly. If the blade rotates in the wrong direction, you have to change the
connection of two phases.
4.2.12
Connection of dust extraction system
The tube is 80 mm mounted on the guard. With a Y-connection of the hose can be con-
nected together with the dust extraction under the worktop to a dust extraction system.
4.3
Earthing connection
A T T E N T I O N
When working on an ungrounded machine:
Serious injury due to electric shock in the event of a malfunction possible!
Therefore:
Machine must be grounded and be connected to a grounded outlet
The electrical connection of the machine is ready for operation on a grounded electri-
cal outlet!
The plug must be connected only to a properly fitted and grounded electrical outlet!
The supplied plug must not be changed. If the plug does not fit or is defective, only a
qualified electrical engineer may modify or replace these plugs!
The grounding conductor is green-yellow!
In the event of repair or replacement of the grounding conductor must not be con-
nected to an under voltage can!
Check with a qualified electrician or service that the grounding instructions are under-
stood and the machine is grounded!
A damaged cable must be replaced immediately!