HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at
40
TK255
Fault
Possible cause
correction
Motor does not run
(Extension) cable defective or too
long.
Unplug, check with another machine. Check
minimum cross-section!
Power supply (voltage, frequency). Match power supply to requirements from
Technical Data
Motor defect
Replace or ask for service
ON-OFF switch defective
Repair/replace switch
Carbon brushes defective
Replace carbon brushes
Overload protection activated
see chapter Overload protection
Saw blade gets stuck Incorrectly adjusted riving knife
Not suitable saw blade
Blunt saw blade
Material too hard or cutting too
fast.
Adjust riving knife Distance 3-8 mm to circular
saw blade
Use a circular saw blade recommended for your
material
Replace sawblade
Adjust cutting speed to workpiece hardness &
motor power!
Material kickback
Blunt saw blade
Replace saw blade
Saw blade incorrectly assembled
Check and correct
Cutting angle isn’t
correct / mitre angle
isn’t correct
Incorrectly adjusted rip fence
Incorrectly adjusted mitre fence
adjust
Poor cutting results
Wrong saw blade
Incorrect cutting speed
Change saw blade
Adjust cutting speed